DD IEC/TS 60695-2-20:2004
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
Fire hazard testing Glowing/hot wire based test methods - Hot-wire coil ignitability. Apparatus, test method and guidance
Hardcopy , PDF
20-04-2012
English
21-05-2004
FOREWORD
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Significance of test
6 Apparatus
6.1 Test chamber
6.2 Ignition source
6.3 Supply circuit
6.4 Test fixture
6.5 Test specimen winding device
6.6 Test specimen winding support
6.7 Conditioning chamber
7 Determination of current (I[c])
8 Test specimens
8.1 Test specimen preparation
8.2 Test specimen thickness
9 Conditioning
9.1 Test specimen conditioning
9.2 Heater wire conditioning
9.3 Test conditions
10 Test procedure
11 Observations and measurements
12 Evaluation of test results
13 Test report
Annex A (informative) Determination of current I[c]
Annex B (informative) Performance level category (PLC)
Annex C (informative) Examples of results
Bibliography
Applies to solid electrical insulating materials. Intends to measure the time required to ignite the test specimen during the application of heat from an electrically heated coil as an ignition source.
Committee |
GEL/89
|
DevelopmentNote |
Supersedes BS IEC 60695-2.20. (03/2010)
|
DocumentType |
Standard
|
Pages |
22
|
PublisherName |
British Standards Institution
|
Status |
Withdrawn
|
Supersedes |
Applicable to solid electrical insulating materials. It is intended to measure the time required to ignite the test specimen during the application of heat from an electrically heated coil as an ignition source. This test method is not valid for determining the ignition behaviour of complete items of equipment, since the dimensions of the insulating systems or combustible parts, the design and heat transfer to adjacent metallic or non-metallic parts, etc. greatly influence the ignitability of the electrical insulating materials used therein. In addition, it is not valid for determining fire behaviour and fire hazard of equipment. The data may be used for the preselection of a material as described in IEC 60695-1-30. The optional Performance Level Category (PLC) system described in Annex B is intended for the preselection of component materials for products. An alternative test for ignitability is IEC 60695-2-13. However, no correlation has been established between IEC 60695-2-20 and IEC 60695-2-13. The status of this publication has been reassigned from an International Standard to a Technical Specification, however, the structure and layout remains essentially the same. Every technical aspect of this test method has been reviewed in an attempt to improve both the repeatability and reproducibility. Annex A has been added for the determination of the test current Ic. Annex B has been added which introduces the concept of a Performance Level Category (PLC). Has the status of a basic safety publication in accordance with IEC Guide 104
ISO 293:2004 | Plastics — Compression moulding of test specimens of thermoplastic materials |
IEC 60695-1-30:2017 | Fire hazard testing - Part 1-30: Guidance for assessing the fire hazard of electrotechnical products - Preselection testing process - General guidelines |
ISO 295:2004 | Plastics — Compression moulding of test specimens of thermosetting materials |
ISO 13943:2017 | Fire safety — Vocabulary |
IEC 60695-2-13:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-13: Glowing/hot-wire based test methods- Glow-wire ignition temperature (GWIT) test method for materials |
IEC GUIDE 104:2010 | The preparation of safety publications and the use of basic safety publications and group safety publications |
ISO 291:2008 | Plastics Standard atmospheres for conditioning and testing |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.