DEFSTAN 02-517(PT1)/2(2008) : 2008
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
REQUIREMENTS FOR CABLE, ELECTRIC - PART 1: PRESSURE-TIGHT ETHYLENE PROPYLENE RUBBER (EPR) OR SILICONE RUBBER INSULATED, CHLOROSULPHONATED POLYETHYLENE (CSP) LIMITED FIRE HAZARD (LFH) SHEATHED
Hardcopy , PDF
17-02-2023
English
01-01-2008
Foreword
Introduction
1 Scope
2 Warning
3 Related Documents
4 Performance Specification
5 National/International Regulations
6 Military Standards/Requirements
6.1 Requirements for Materials
6.1.1 Conductor
6.1.2 Filler Material
6.1.3 Conductor Insulation
6.1.4 Glass Braid
6.1.5 Lacquer
6.1.6 Binding Tapes
6.1.7 Electrical Screen
6.1.8 Sheath
6.1.9 Approved Insulation Materials
6.2 Construction
6.2.1 Conductor Stranding
6.2.2 Conductor Insulation
6.2.3 Identification of Cores
6.2.4 Laying Up of Cores
6.2.5 Type E Twisted Pair Cables
6.2.6 Multicore EPR Cables
6.2.7 Multi-triple EPR Cables
6.2.8 Screens
6.2.9 Sheathing
6.2.10 Tolerances
6.2.11 Marking
6.3 Tests
6.3.1 Scheduled Tests
6.3.2 Tests on Cable Components
6.3.3 Tests on Components from Completed Cable
6.3.4 Tests on Completed Cable
6.4 Qualification Approval Procedures
6.4.1 Definitions
6.4.2 General Requirements
6.4.3 Qualification Approval Testing
6.4.4 Test Reports
6.4.5 Qualification Approval Certificates
6.5 Quality Assurance of Products
6.5.1 Procedure
6.5.2 Tests and Sampling Levels on Completed Cables
6.6 Packaging and Labelling
6.6.1 General
6.6.2 Packaging
6.6.3 Supply on Reels
6.6.4 Supply on Drums
6.6.5 Despatch Lengths
7 Design Requirements/Guidance
8 Corporate Knowledge And Experience
Annex A - Abbreviations and Definitions
Annex B - Procurement Check List
Annex C - Standard Form of Report for Qualification Approval,
Production Quality and Production Routine Tests
Annex D - Tables of Dimensions
D.1 General
Covers the manufacture and testing requirements of Ethylene Propylene Rubber (EPR) or Silicone Rubber Insulated Chlorosulphonated Polyethylene (CSP) (Limited Fire Hazard (LFH)) sheathed, pressure-tight cables for power, lighting, control and communication and instrumentation circuits in HM Surface Ships and Submarines.
DevelopmentNote |
Supersedes DEFSTAN 02-517(PT1)/1(2000). (02/2008) This standard is obsolescent because it is no longer required for the procurement of new equipment but is retained for maintenance purposes in support of existing in-service equipment. (01/2014)
|
DocumentType |
Standard
|
Pages |
46
|
PublisherName |
UK Ministry of Defence Standards
|
Status |
Superseded
|
SupersededBy | |
Supersedes |
DEFSTAN 07-247(PT1)/3(2009) : 2009 | THE SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS - PART 1: SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS |
DEFSTAN 02-607/2(2008) : 2008 | DESIGN OF HIGH VOLTAGE ELECTRICAL POWER SYSTEMS FOR HM SHIPS, SUBMARINES AND THE ROYAL FLEET AUXILIARY |
DEFSTAN 02-607/3(2013) : 2013 | DESIGN OF HIGH VOLTAGE ELECTRICAL POWER SYSTEMS FOR HM SHIPS, SUBMARINES AND THE ROYAL FLEET AUXILIARY |
BS EN 50265-1:1999 | Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable Apparatus |
DEFSTAN 81-41(PT1)/6(2006) : 2006 | PACKAGING OF DEFENCE MATERIEL - PART 1: INTRODUCTION TO DEFENCE PACKAGING REQUIREMENTS |
BS EN 50267-1:1999 | Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables Apparatus |
BS EN 50265-2-1:1999 | Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame |
DEFSTAN 61-12(PT31)/2(2006) : 2006 | WIRES, CORDS AND CABLES, ELECTRICAL - METRIC UNITS - PART 31: SHEATHS - LIMITED FIRE HAZARD |
BS EN 60811-1-4:1995 | Insulating and sheathing materials of electric cables. Common test methods. General application Tests at low temperature |
BS EN ISO 9000:2015 | Quality management systems. Fundamentals and vocabulary |
DEFSTAN 02-527/1(2000) : 2000 | REQUIREMENTS FOR CABLES, ELECTRIC, FIRE SURVIVAL, HIGH TEMPERATURE ZONES AND LIMITED FIRE HAZARD SHEATHED CATEGORY 2 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.