• Shopping Cart
    There are no items in your cart

DEFSTAN 02-517(PT1)/2(2008) : 2008

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

REQUIREMENTS FOR CABLE, ELECTRIC - PART 1: PRESSURE-TIGHT ETHYLENE PROPYLENE RUBBER (EPR) OR SILICONE RUBBER INSULATED, CHLOROSULPHONATED POLYETHYLENE (CSP) LIMITED FIRE HAZARD (LFH) SHEATHED

Available format(s)

Hardcopy , PDF

Superseded date

17-02-2023

Language(s)

English

Published date

01-01-2008

€14.02
Excluding VAT

Foreword
Introduction
1 Scope
2 Warning
3 Related Documents
4 Performance Specification
5 National/International Regulations
6 Military Standards/Requirements
  6.1 Requirements for Materials
      6.1.1 Conductor
      6.1.2 Filler Material
      6.1.3 Conductor Insulation
      6.1.4 Glass Braid
      6.1.5 Lacquer
      6.1.6 Binding Tapes
      6.1.7 Electrical Screen
      6.1.8 Sheath
      6.1.9 Approved Insulation Materials
  6.2 Construction
      6.2.1 Conductor Stranding
      6.2.2 Conductor Insulation
      6.2.3 Identification of Cores
      6.2.4 Laying Up of Cores
      6.2.5 Type E Twisted Pair Cables
      6.2.6 Multicore EPR Cables
      6.2.7 Multi-triple EPR Cables
      6.2.8 Screens
      6.2.9 Sheathing
      6.2.10 Tolerances
      6.2.11 Marking
  6.3 Tests
      6.3.1 Scheduled Tests
      6.3.2 Tests on Cable Components
      6.3.3 Tests on Components from Completed Cable
      6.3.4 Tests on Completed Cable
  6.4 Qualification Approval Procedures
      6.4.1 Definitions
      6.4.2 General Requirements
      6.4.3 Qualification Approval Testing
      6.4.4 Test Reports
      6.4.5 Qualification Approval Certificates
  6.5 Quality Assurance of Products
      6.5.1 Procedure
      6.5.2 Tests and Sampling Levels on Completed Cables
  6.6 Packaging and Labelling
      6.6.1 General
      6.6.2 Packaging
      6.6.3 Supply on Reels
      6.6.4 Supply on Drums
      6.6.5 Despatch Lengths
7 Design Requirements/Guidance
8 Corporate Knowledge And Experience
Annex A - Abbreviations and Definitions
Annex B - Procurement Check List
Annex C - Standard Form of Report for Qualification Approval,
          Production Quality and Production Routine Tests
Annex D - Tables of Dimensions
  D.1 General

Covers the manufacture and testing requirements of Ethylene Propylene Rubber (EPR) or Silicone Rubber Insulated Chlorosulphonated Polyethylene (CSP) (Limited Fire Hazard (LFH)) sheathed, pressure-tight cables for power, lighting, control and communication and instrumentation circuits in HM Surface Ships and Submarines.

DevelopmentNote
Supersedes DEFSTAN 02-517(PT1)/1(2000). (02/2008) This standard is obsolescent because it is no longer required for the procurement of new equipment but is retained for maintenance purposes in support of existing in-service equipment. (01/2014)
DocumentType
Standard
Pages
46
PublisherName
UK Ministry of Defence Standards
Status
Superseded
SupersededBy
Supersedes

DEFSTAN 07-247(PT1)/3(2009) : 2009 THE SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS - PART 1: SELECTION OF MATERIALS ON THE BASIS OF THEIR FIRE CHARACTERISTICS
DEFSTAN 02-607/2(2008) : 2008 DESIGN OF HIGH VOLTAGE ELECTRICAL POWER SYSTEMS FOR HM SHIPS, SUBMARINES AND THE ROYAL FLEET AUXILIARY
DEFSTAN 02-607/3(2013) : 2013 DESIGN OF HIGH VOLTAGE ELECTRICAL POWER SYSTEMS FOR HM SHIPS, SUBMARINES AND THE ROYAL FLEET AUXILIARY

BS EN 50265-1:1999 Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable Apparatus
DEFSTAN 81-41(PT1)/6(2006) : 2006 PACKAGING OF DEFENCE MATERIEL - PART 1: INTRODUCTION TO DEFENCE PACKAGING REQUIREMENTS
BS EN 50267-1:1999 Common test methods for cables under fire conditions. Tests on gases evolved during combustion of materials from cables Apparatus
BS EN 50265-2-1:1999 Common test methods for cables under fire conditions. Test for resistance to vertical flame propagation for a single insulated conductor or cable. Procedures 1 kW pre-mixed flame - 1 kW pre-mixed flame
DEFSTAN 61-12(PT31)/2(2006) : 2006 WIRES, CORDS AND CABLES, ELECTRICAL - METRIC UNITS - PART 31: SHEATHS - LIMITED FIRE HAZARD
BS EN 60811-1-4:1995 Insulating and sheathing materials of electric cables. Common test methods. General application Tests at low temperature
BS EN ISO 9000:2015 Quality management systems. Fundamentals and vocabulary
DEFSTAN 02-527/1(2000) : 2000 REQUIREMENTS FOR CABLES, ELECTRIC, FIRE SURVIVAL, HIGH TEMPERATURE ZONES AND LIMITED FIRE HAZARD SHEATHED CATEGORY 2

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.