• Shopping Cart
    There are no items in your cart

DIN 18807-2:1987-06

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

TRAPEZOIDAL SHEETING IN BUILDING - TRAPEZOIDAL STEEL SHEETING - DETERMINATION OF LOADBEARING CAPACITY BY TESTING

Available format(s)

Hardcopy , PDF

Withdrawn date

01-06-2011

Language(s)

English

Published date

01-01-1987

1 Field of application
2 Symbols
3 Test configuration
      3.1 General
      3.2 Dimensions, auxiliary structures and positioning
             of test sheets
      3.3 'Single-span beam' test (Test A)
      3.4 'Intermediate support' test (Test B)
      3.5 'End support' test (Test C)
      3.6 'Multiple-span beam' test (Test D)
      3.7 Impact (walkability) test (Test E)
4 Test procedure
      4.1 General
      4.2 Measurement of profile dimensions
      4.3 Determination of self-weight of loading device
      4.4 Rate of loading
      4.5 Materials testing
5 Number of tests
      5.1 Minimum number of sheet thicknesses to be tested
      5.2 Minimum number of tests
      5.3 Minimum number of effective spans to be tested
             in Tests B and D
6 Presentation of results
7 Evaluation of test results
      7.1 General
      7.2 Action-effects
      7.3 Test A
      7.4 Test B
      7.5 Test C
      7.6 Test D
      7.7 Test E
8 Design
Standards and other documents referred to

Deals with the procedure and evaluation of tests for determining the loadbearing capacity of corrosion-protected trapezoidal (profiled) steel sheeting subjected to predominantly static loading (c.f. sub-clause 1.4 of DIN 1055 Part 3, June 1971 edition), which is used in building construction for roofs, floors, walls and wall cladding (see Figure 2 in DIN 18807 Part 1, June 1997 edition, for examples of profiled types).

DocumentType
Standard
Pages
10
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Withdrawn

DIN 18807-2 : 1987 AMD 1 2001 TRAPEZOIDAL SHEETING IN BUILDING - STEEL TRAPEZOIDAL SHEETING - EXECUTION AND EVALUATION OF ULTIMATE STRENGTH TESTS
DIN 18807-3:1987-06 TRAPEZOIDAL SHEETING IN BUILDING - STEEL TRAPEZOIDAL SHEETING - STRENGTH ANALYSIS, STRUCTURAL DESIGN
DIN 18807-1 : 1987 AMD 1 2001 TRAPEZOIDAL SHEETING IN BUILDING - TRAPEZOIDAL STEEL SHEETING - GENERAL REQUIREMENTS AND DETERMINATION OF LOADBEARING CAPACITY BY CALCULATION

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.