• Shopping Cart
    There are no items in your cart

DIN EN 12341:1999-03

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

AMBIENT AIR - STANDARD GRAVIMETRIC MEASUREMENT METHOD FOR THE DETERMINATION OF THE PM[10] OR PM[2],[5] MASS CONCENTRATION OF SUSPENDED PARTICULATE MATTER

Available format(s)

Hardcopy , PDF

Superseded date

07-03-2021

Superseded by

DIN EN 12341:2014-08

Language(s)

English

Published date

01-01-1999

€170.93
Excluding VAT

National foreword
National Annex NA (informative) - Bibliography
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Principle
5 Equipment and facilities
6 Filter conditioning, sampling and weighing
  procedures
7 Ongoing quality control
8 Expression of results
9 Performance characteristics of the method
Annex A (normative) - Design drawing of standard
        inlet for the sampling of PM[10] and PM[2],[5]
Annex B (normative) - Other samplers
Annex C (informative) - Scheme of PM standard sampler
Annex D (informative) - Suitability tests for filters
Annex E (normative) - Initial suitability testing of
weighing facilities
Annex F (informative) - Results of experimental work
Annex G (informative) - Impactor efficiency
Bibliography

Defines a standard method for determining the PM[10] or PM[2],[5] mass concentrations of suspended particulate matter in ambient air by sampling the particulate matter on filters and weighing them by means of a balance.

DevelopmentNote
Supersedes DIN EN 14907 E. (08/2014)
DocumentType
Standard
Pages
26
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded
SupersededBy

Standards Relationship
ONORM EN 12341 : 2014 Identical
EN 12341:2014 Identical
NS EN 12341 : 2014 Identical
NEN EN 12341 : 2014 Identical
NF EN 12341 : 2014 Identical
BS EN 12341:2014 Identical
NBN EN 12341 : 2014 Identical
SN EN 12341:2014 Identical
I.S. EN 12341:2014 Identical
UNI EN 12341 : 2014 Identical
UNE-EN 12341:2015 Identical

VDI 2268 Blatt 3:1988-12 Chemical analysis of particulate matter; determination of thallium in particulate emissions by atomic absorption spectrometry
ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
EN 13274-7:2008 Respiratory protective devices - Methods of test - Part 7: Determination of particle filter penetration
VDI 2267 Blatt 12:2008-10 Determination of suspended matter in ambient air - Measurement of As, Ca, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sb and Zn by energy dispersive X-ray fluorescense (ED XRF)
CEN/TR 16269:2011 Ambient air - Guide for the measurement of anions and cations in PM2,5
VDI 2267 Blatt 5:1997-11 Determination of suspended matter in ambient air - Determination of the mass concentration of Be, Cd, Co, Cr, Cu, Fe, Mn, Ni, Pb, Sb, V, Zn by optical emission spectrometry (ICP-OES) after sampling on filters and digestion in an oxidising agent
VDI 2463 Blatt 7:2014-05 Particulate matter measurement - Determination of suspended particulate matter and gaseous chemical compounds in ambient air and indoor air - Active sampling via low-volume sampler (LVS)
EN 14907:2005 Ambient air quality - Standard gravimetric measurement method for the determination of the PM2,5 mass fraction of suspended particulate matter
VDI 3498 Blatt 2:2002-07 Ambient air measurement - Indoor air measurement - Measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans; Method using small filters
DIN EN 15549:2008-06 Air quality - Standard method for the measurement of the concentration of benzo[a]pyrene in ambient air
CEN/TR 16243:2011 Ambient air quality - Guide for the measurement of elemental carbon (EC) and organic carbon (OC) deposited on filters
VDI 2463 Blatt 11:1996-10 Particulate matter measurement - Measurement of mass concentration in ambient air - Filter method; Digitel DHA-80 filter changer
VDI 2267 Blatt 16:2007-07 Determination of suspended matter in ambient air - Measurement of the mass concentration of As, Cd, Co, Cr, Cu, Ni, Pb, Sb, V und Zn as part of dust precipitation by atomic absorption spectrometry (AAS)
CEN/TS 16450:2013 Ambient air - Automated measuring systems for the measurement of the concentration of particulate matter (PM10; PM2,5)
VDI 3867 Blatt 6:2012-12 Measurement of particles in ambient air - Determination of the particle number concentration and number size distribution of aerosols - Electrical Low Pressure Impactor (ELPI)
VDI 2464 Blatt 3:2012-07 Ambient air measurement - Indoor air measurement - Measurement of polybrominated diphenylether, hexabromocyclododecane and hexabromobenzene by GC/MS
VDI 3867 Blatt 5:2013-11 Measurement of particles in ambient air - Determination of the particle number concentration and particle size distribution of aerosols - Time-of-flight spectrometer
VDI 2267 Blatt 15:2005-11 Determination of suspended matter in ambient air - Measurement of the mass concentration of Al, As, Ca, Cd, Co, Cr, Cu, K, Mn, Ni, Pb, Sb, V, Zn as part of dust precipitation by mass spectrometry (ICP-MS)
VDI 2267 Blatt 7:1988-11 Chemical analysis of particulates in ambient air; determination of thallium and its inorganic compounds as part of the dust precipitation by atomic absorption spectrometry
VDI 3867 Blatt 3:2012-08 Measurement of particles in ambient air - Determination of the particle number concentration and number size distribution of aerosols - Electrical mobility spectrometer
VDI 2268 Blatt 1:1987-04 Chemical analysis of particulate matter; determination of Ba, Be, Cd, Co, Cr, Cu, Ni, Pb, Sr, V, Zn in particulate emissions by atomic spectrometric methods
VDI 2267 Blatt 9:2002-07 Determination of suspended particulates matter in ambient air - Measurement of the mass concentration of mercury - Sampling by sorption as amalgam and determination by atomic fluorescense spectrometry (AFS) with cold vapour technique
EN 1822-1:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking
VDI 3867 Blatt 2:2008-02 Measurement of particulate matter in ambient air - Methods for characterizing test aerosols - Determination of the particle number concentration and particle size distribution - Condensation Particle Counter (CPC)
EN 15549:2008 Air quality - Standard method for the measurement of the concentration of benzo[a]pyrene in ambient air
VDI 3867 Blatt 4:2011-06 Measurement of particles in ambient air - Determination of the particle number concentration and particle size distribution of aerosols - Optical aerosol spectrometer
VDI 2267 Blatt 1:2012-10 Determination of suspended matter in ambient air - Measurement of the element concentration after sampling on filters - Determination of Al, As, Ba, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, Sb, Se, Sn, Tl, V and Zn by graphite furnace atomic absorption spectrometry (GF-AAS), by optical emission spectrometry with inductively coupled plasma (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS)
EN 12341:2014 Ambient air - Standard gravimetric measurement method for the determination of the PM10 or PM2,5 mass concentration of suspended particulate matter
VDI 2267 Blatt 14:2003-12 Determination of suspended matter in ambient air - Measurement of Al, As, Ca, Cd, Co, Cr, Cu, Fe, K, Mg, Mn, Na, Ni, Pb, V, Zn as part of dust deposition by optical emission spectrometry (ICP OES)
VDI 3498 Blatt 1:2002-07 Ambient air measurement - Indoor air measurement - Measurement of polychlorinated dibenzo-p-dioxins and dibenzofurans; Method using large filters
VDI 2267 Blatt 2:1983-02 Determination of suspended particulates in ambient air; measurement of lead by X-ray fluorescence

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.