• DIN EN 13501-6 E : 2014

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    FIRE CLASSIFICATION OF CONSTRUCTION PRODUCTS AND BUILDING ELEMENTS - PART 6: CLASSIFICATION USING DATA FROM REACTION TO FIRE TESTS ON ELECTRIC CABLES

    Available format(s): 

    Superseded date:  02-05-2019

    Language(s): 

    Published date:  08-09-2014

    Publisher:  German Institute for Standardisation (Deutsches Institut für Normung)

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    National foreword
    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms, definitions and symbols
    4 Classes of reaction to fire performance
    5 Test methods
    6 Principles for specimen preparation
    7 Number of tests for classification
    8 Testing of electric cables
    9 Classification criteria for electric cables
    10 Presentation of classification
    11 Field of application of the classification
    12 Classification report
    Annex A (normative) - Reaction to fire classification
            report for electric cables
    Annex B (informative) - Background information as
            regards the reaction to fire performance of cables
    Bibliography

    Abstract - (Show below) - (Hide below)

    Gives the reaction to fire classification procedure for electric cables.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 50399 : 2011 AMD 1 2016 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - HEAT RELEASE AND SMOKE PRODUCTION MEASUREMENT ON CABLES DURING FLAME SPREAD TEST - TEST APPARATUS, PROCEDURES, RESULTS
    PREN 50575 : DRAFT 2012 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
    ISO 1716:2010 Reaction to fire tests for products Determination of the gross heat of combustion (calorific value)
    ISO 13943:2017 Fire safety — Vocabulary
    IEC 60332-1-2:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame
    EN 61034-2:2005/A1:2013 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013)
    EN ISO 13943:2017 Fire safety - Vocabulary (ISO 13943:2017)
    EN 50267-2-3:1998 Common test methods for cables under fire conditions - Tests on gases evolved during combustion of materials from cables - Part 2-3: Procedures - Determination of degree of acidity of gases for cables by determination of the weighted average of pH and conductivity
    EN ISO 1716:2010 Reaction to fire tests for products - Determination of the gross heat of combustion (calorific value) (ISO 1716:2010)
    IEC 61034-2:2005+AMD1:2013 CSV Measurement of smoke density of cables burning under definedconditions - Part 2: Test procedure and requirements
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective