• IEC 60332-1-2:2004+AMD1:2015 CSV

    Current The latest, up-to-date edition.

    Tests on electric and optical fibre cables under fire conditions - Part 1-2: Test for vertical flame propagation for a single insulatedwire or cable - Procedure for 1 kW pre-mixed flame

    Available format(s):  Hardcopy, PDF, PDF 3 Users, PDF 5 Users, PDF 9 Users

    Language(s):  English - French

    Published date:  28-07-2015

    Publisher:  International Electrotechnical Committee

    Add To Cart

    Abstract - (Show below) - (Hide below)

    IEC 60332-1-2:2004+A1:2015 Specifies the procedure for testing the resistance to vertical flame propagation for a single vertical electrical insulated conductor or cable, or optical fibre cable, under fire conditions. The apparatus is given in IEC 60332-1-1.
    NOTE 1 Testing to IEC 60332-1-2 may be performed simultaneously with that to IEC 60332-1-3 if required. Recommended requirements for performance are given in Annex A. IEC 60332-1-2 specifies the use of a 1 kW pre-mixed flame and is for general use, except that the procedure specified may not be suitable for the testing of small single insulated conductors or cables of less than 0,5 mm² total cross-section because the conductor melts before the test is completed, or for the testing of small optical fibre cables because the cable is broken before the test is completed. In these cases, the procedure given in IEC 60332-2-2 is recommended.
    NOTE 2 Since the use of insulated conductor or cable which retards flame propagation and complies with the recommended requirements of this standard is not sufficient by itself to prevent propagation of fire under all conditions of installation, it is recommended that wherever the risk of propagation is high, for example in long vertical runs of bunches of cables, special installation precautions should also be taken. It cannot be assumed that because the sample of cable complies with the performance requirements recommended in this standard, that a bunch of cables will behave in a similar manner. (See IEC 60332-3 series.)
    This consolidated version consists of the first edition (2004) and its amendment 1 (2015). Therefore, no need to order amendment in addition to this publication.

    General Product Information - (Show below) - (Hide below)

    Development Note Together with IEC 60332-1-1 supersedes IEC 60332-1. (07/2004) Stability Date: 2021. (07/2015)
    Document Type Standard
    Publisher International Electrotechnical Committee
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    NFC 32 102-15 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 15: MULTICORE CABLES INSULATED AND SHEATHED WITH HEAT RESISTANT SILICONE RUBBER
    UNE-EN 50620:2017 Electric cables - Charging cables for electric vehicles
    CEI 18-49 : 2013 ELECTRICAL INSTALLATIONS IN SHIPS - PART 350: GENERAL CONSTRUCTION AND TEST METHODS OF POWER, CONTROL AND INSTRUMENTATION CABLES FOR SHIPBOARD AND OFFSHORE APPLICATIONS
    CEI EN 61375-3-1 : 2013 ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK (TCN) - PART 3-1: MULTIFUNCTION VEHICLE BUS (MVB)
    BS ISO/IEC/IEEE 80005-1:2012 Utility connections in port High Voltage Shore Connection (HVSC) Systems. General requirements
    UNE-EN 50525-2-72:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) -- Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
    16/30337938 DC : 0 BS EN 80005-1 - UTILITY CONNECTIONS IN PORT - HIGH VOLTAGE SHORE CONNECTION (HVSC) SYSTEMS - PART 1: GENERAL REQUIREMENTS
    IEC 63010-1:2017 Halogen-free thermoplastic insulated and sheathed flexible cables of rated voltages up to and including 300/300 V - Part 1: General requirements and cables
    BS EN 50382-2 : 2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 2: SINGLE CORE SILICONE RUBBER INSULATED CABLES FOR 120 DEGREES C OR 150 DEGREES C
    BS EN 50525-3-41:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free crosslinked insulation, and low emission of smoke
    PREN 50525-2-83 : DRAFT 2008 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-83: CABLES FOR GENERAL APPLICATIONS - MULTICORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
    CEI EN 50525-2-51 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-51: CABLES FOR GENERAL APPLICATIONS - OIL RESISTANT CONTROL CABLES WITH THERMOPLASTIC PVC INSULATION
    16/30337092 DC BS EN 13378. Pasta processing plant. Pasta presses. Safety and hygiene requirements
    15/30314469 DC : 0 BS EN 62548 ED.1 - PHOTOVOLTAIC (PV) ARRAYS - DESIGN REQUIREMENTS
    09/30205454 DC : 0 BS EN 61375-3-1 - ELECTRONIC RAILWAY EQUIPMENT - TRAIN COMMUNICATION NETWORK - PART 3-1: MVB - MULTIPURPOSE VEHICLE BUS
    UNE-EN 50525-3-11:2012 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (Uo/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
    CEI EN 50143 : 2012 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
    BS EN 60695-1-10:2017 FIRE HAZARD TESTING - PART 1-10: GUIDANCE FOR ASSESSING THE FIRE HAZARD OF ELECTROTECHNICAL PRODUCTS - GENERAL GUIDELINES
    08/30188796 DC : 0 BS EN 50525-2-41 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
    BS EN 50143:2009 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
    10/30215871 DC : 0 BS EN 50441-4 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 4
    I.S. HD 632:2016 POWER CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES ABOVE 36 KV (U[M] = 42 KV) UP TO 150 KV (U[M] = 170 KV)
    06/30151267 DC : 0 BS ISO CD 10840 - PLASTICS - GUIDANCE FOR THE USE OF STANDARD FIRE TESTS
    08/30188839 DC : 0 BS EN 50525-3-31 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-31: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
    17/30347740 DC : 0 BS EN 63075 - SUPERCONDUCTING AC POWER CABLES AND THEIR ACCESSORIES FOR RATED VOLTAGES FROM 6 KV TO 500 KV - TEST METHODS AND REQUIREMENTS
    BS EN 50525-2-31:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables for general applications. Single core non-sheathed cables with thermoplastic PVC insulation
    BS EN 50264-2-2:2008 Railway applications. Railway rolling stock power and control cables having special fire performance Cables with crosslinked elastomeric insulation. Multicore cables
    14/30289997 DC : 0 BS EN 62893-1 - CHARGING CABLES FOR ELECTRIC VEHICLES - PART 1: GENERAL REQUIREMENTS
    10/30185766 DC : 0 BS EN 1889-1 - MACHINES FOR UNDERGROUND MINES - MOBILE MACHINES WORKING UNDERGROUND - SAFETY - PART 1: RUBBER TYRED VEHICLES
    10/30215867 DC : 0 BS EN 50441-2 - CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 2
    09/30196635 DC : 0 BS EN 60092-510 - ELECTRICAL INSTALLATIONS IN SHIPS - SPECIAL FEATURES - HIGH VOLTAGE SHORE CONNECTION SYSTEMS (HVSC-SYSTEMS)
    CEI EN 60332-2-2 : 2006 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 2-2: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE SMALL INSULATED WIRE OR CABLE - PROCEDURE FOR DIFFUSION FLAME
    09/30166429 DC : 0 BS 8492 - TELECOMMUNICATIONS EQUIPMENT AND TELECOMMUNICATIONS CABLING - CODE OF PRACTICE FOR FIRE PERFORMANCE AND PROTECTION
    08/30188842 DC : 0 BS EN 50525-3-41 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3-41: CABLES WITH SPECIAL FIRE PERFORMANCE - SINGLE CORE NON-SHEATHED CABLES WITH HALOGEN-FREE CROSS LINKED INSULATION, AND LOW EMISSION OF SMOKE
    CSA C22.2 No. 61010.1 :2012 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
    I.S. HD 22.9:2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 9: SINGLE CORE HALOGEN-FREE NON-SHEATHED CABLES FOR FIXED WIRING HAVING LOW EMISSION OF SMOKE
    I.S. HD 603:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
    CEI EN 50525-2-41 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-41: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE CABLES WITH CROSSLINKED SILICONE RUBBER INSULATION
    S.R. HD 60364-4-42:2011 LOW VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS
    S.R. CLC/TS 50576:2016 ELECTRIC CABLES - EXTENDED APPLICATION OF TEST RESULTS FOR REACTION TO FIRE
    NFC 32 102-16 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
    I.S. EN 50618:2014 ELECTRIC CABLES FOR PHOTOVOLTAIC SYSTEMS
    IEC TR 60092-370:2009 Electrical installations in ships - Part 370: Guidance on the selection of cables for telecommunication and data transfer including radio-frequency cables
    BS EN 50575 : 2014 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
    I.S. EN 50620:2017 ELECTRIC CABLES - CHARGING CABLES FOR ELECTRIC VEHICLES
    I.S. EN 50441-4:2012 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 4: CABLES UP TO 1200 MHZ - GRADE 3
    I.S. EN 50264-3-1:2008 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK POWER AND CONTROL CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 3-1: CABLES WITH CROSSLINKED ELASTOMERIC INSULATION WITH REDUCED DIMENSIONS - SINGLE CORE CABLES
    IEEE 525-2007 DESIGN AND INSTALLATION OF CABLE SYSTEMS IN SUBSTATIONS
    CEI EN 50525-2-72 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-72: CABLES FOR GENERAL APPLICATIONS - FLAT DIVISIBLE CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
    ISO/IEC 14763-2:2012 Information technology Implementation and operation of customer premises cabling Part 2: Planning and installation
    S.R. HD 60364-5-56:2010 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-56: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - SAFETY SERVICES
    CEI EN 50441-2 : 2013 CABLES FOR INDOOR RESIDENTIAL TELECOMMUNICATION INSTALLATIONS - PART 2: SCREENED CABLES - GRADE 1
    CEI EN 50525-3-11 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 3-11: CABLES WITH SPECIAL FIRE PERFORMANCE - FLEXIBLE CABLES WITH HALOGEN-FREE THERMOPLASTIC INSULATION, AND LOW EMISSION OF SMOKE
    NFC 32 102-13 : 2007 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
    NF EN 50143 : 2009 CABLES FOR SIGNS AND LUMINOUS-DISCHARGE-TUBE INSTALLATIONS OPERATING FROM A NO-LOAD RATED OUTPUT VOLTAGE EXCEEDING 1000 V BUT NOT EXCEEDING 10000 V
    CSA C22.2 No. 61010.1 : 2012 : INC : UPD 1 :2015 SAFETY REQUIREMENTS FOR ELECTRICAL EQUIPMENT FOR MEASUREMENT, CONTROL, AND LABORATORY USE - PART 1: GENERAL REQUIREMENTS
    IEC 62821-1:2015 Electric cables - Halogen-free, low smoke, thermoplastic insulated and sheathed cables of rated voltages up to and including 450/750 V - Part 1: General requirements
    AAMI ES60601-1 : 2005 : INC : AMD 1 : 2012 : R201200 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD)
    AAMI ES60601-1 : 2005 : INC : AMD 2 : 2012 : R201200 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD)
    AAMI ES60601-1 : 2005 : R2012 MEDICAL ELECTRICAL EQUIPMENT - PART 1: GENERAL REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE (IEC 60601-1:2005, MOD)
    CSA C22.2 No. 62368-1 : 2014 AUDIO/VIDEO, INFORMATION AND COMMUNICATION TECHNOLOGY EQUIPMENT - PART 1: SAFETY REQUIREMENTS
    DIN EN 13378:2016-05 (Draft) PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS
    EN 60695-9-2:2014 Fire hazard testing - Part 9-2: Surface spread of flame - Summary and relevance of test methods
    03/318326 DC : DRAFT NOV 2003
    17/30338554 DC : 0 BS EN 1175 - SAFETY OF INDUSTRIAL TRUCKS - ELECTRICAL/ELECTRONIC REQUIREMENTS
    BS EN 50174-2 : 2009 INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 2: INSTALLATION PLANNING AND PRACTICES INSIDE BUILDINGS
    13/30238229 DC : 0 BS EN 62052-31 - ELECTRICITY METERING EQUIPMENT (AC) - GENERAL REQUIREMENTS, TEST AND TEST CONDITIONS - PART 31: PRODUCT SAFETY REQUIREMENTS
    IEC 60332-1-1:2004+AMD1:2015 CSV Tests on electric and optical fibre cables under fire conditions - Part 1-1: Test for vertical flame propagation for a single insulatedwire or cable - Apparatus
    BS EN 13378 : 2001 PASTA PROCESSING PLANTS - PASTA PRESSES - SAFETY AND HYGIENE REQUIREMENTS
    DIN EN 12601:2011-07 RECIPROCATING INTERNAL COMBUSTION ENGINE DRIVEN GENERATING SETS - SAFETY
    I.S. EN 13289:2001 PASTA PROCESSING PLANTS - DRYERS AND COOLERS - SAFETY AND HYGIENE REQUIREMENTS
    EN 60695-1-10:2017 Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines
    IEC 62067:2011 RLV Power cables with extruded insulation and their accessories for rated voltages above 150 kV (Um = 170 kV) up to 500 kV (Um = 550 kV) - Test methods and requirements
    EN 62052-31:2016 Electricity metering equipment (AC) - General requirements, tests and test conditions - Part 31: Product safety requirements and tests
    EN 50264-2-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 2-1: Cables with crosslinked elastomeric insulation - Single core cables
    EN 60332-1-3:2004/A1:2015 TESTS ON ELECTRIC AND OPTICAL FIBRE CABLES UNDER FIRE CONDITIONS - PART 1-3: TEST FOR VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED WIRE OR CABLE - PROCEDURE FOR DETERMINATION OF FLAMING DROPLETS/PARTICLES (IEC 60332-1-3:2004/A1:2015)
    EN 50525-2-51:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-51: Cables for general applications - Oil resistant control cables with thermoplastic PVC insulation
    HD 620 : 2010 DISTRIBUTION CABLES WITH EXTRUDED INSULATION FOR RATED VOLTAGES FROM 3,6/6 (7,2) KV UP TO AND INCLUDING 20,8/36 (42) KV
    EN 50525-2-31:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-31: Cables for general applications - Single core non-sheathed cables with thermoplastic PVC insulation
    EN 13379:2001+A1:2013 Pasta processing plants - Spreader, stripping and cutting machine, stick return conveyor, stick magazine - Safety and hygiene requirements
    EN 50575:2014/A1:2016 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
    IEC 60695-1-10:2016 RLV Fire hazard testing - Part 1-10: Guidance for assessing the fire hazard of electrotechnical products - General guidelines
    EN 50441-4:2012 Cables for indoor residential telecommunication installations - Part 4: Cables up to 1 200 MHz - Grade 3
    HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
    EN 50525-2-72:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-72: Cables for general applications - Flat divisible cables (cords) with thermoplastic PVC insulation
    EN 50525-3-11:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-11: Cables with special fire performance - Flexible cables with halogen-free thermoplastic insulation, and low emission of smoke
    EN 50441-1:2012 Cables for indoor residential telecommunication installations - Part 1: Unscreened cables - Grade 1
    HD 60364-7-717:2010/AC:2014 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 7-717: REQUIREMENTS FOR SPECIAL INSTALLATIONS OR LOCATIONS - MOBILE OR TRANSPORTABLE UNITS
    EN 12601:2010 Reciprocating internal combustion engine driven generating sets - Safety
    EN 50525-2-81:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-81: Cables for general applications - Cables with crosslinked elastomeric covering for arc welding
    EN 13378:2001+A1:2013 Pasta processing plants - Pasta presses - Safety and hygiene requirements
    EN 60702-1:2002/A1:2015 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES (IEC 60702-1:2002/A1:2015)
    HD 60364-4-42 : 2011 AMD 1 2015 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-42: PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS (IEC 60364-4-42:2010/A1:2014)
    CEI 18-64 : 2008 MOBILE AND FIXED OFFSHORE UNITS - ELECTRICAL INSTALLATIONS - PART 4: CABLES
    EN 50382-1 : 2008 AMD 1 2013 RAILWAY APPLICATIONS - RAILWAY ROLLING STOCK HIGH TEMPERATURE POWER CABLES HAVING SPECIAL FIRE PERFORMANCE - PART 1: GENERAL REQUIREMENTS
    EN 50264-1:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 1: General requirements
    EN 50525-2-71:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 2-71: Cables for general applications - Flat tinsel cables (cords) with thermoplastic PVC insulation
    EN 50525-3-31:2011 Electric cables - Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) - Part 3-31: Cables with special fire performance - Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
    HD 22.13 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 13: HALOGEN-FREE FLEXIBLE CABLES HAVING LOW EMISSION OF SMOKE
    HD 60364-5-52:2011/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-52: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - WIRING SYSTEMS
    EN 50264-3-2:2008 Railway applications - Railway rolling stock power and control cables having special fire performance - Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
    EN 13289:2001+A1:2013 Pasta processing plants - Dryers and coolers - Safety and hygiene requirements
    EN 60332-2-2:2004 Tests on electric and optical fibre cables under fire conditions - Part 2-2: Test for vertical flame propagation for a single small insulated wire or cable - Procedure for diffusion flame
    HD 22.12 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 12: HEAT RESISTANT EPR CORDS AND FLEXIBLE CABLES
    HD 22.16 : 200S2 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING CROSS-LINKED INSULATION - PART 16: WATER RESISTANT POLYCHLOROPRENE OR EQUIVALENT SYNTHETIC ELASTOMER SHEATHED CABLES
    HD 60364-5-559:2012/A11:2017 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 5-559: SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - LUMINAIRES AND LIGHTING INSTALLATIONS
    CEI EN 50525-2-71 : 2012 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-71: CABLES FOR GENERAL APPLICATIONS - FLAT TINSEL CABLES (CORDS) WITH THERMOPLASTIC PVC INSULATION
    BS IEC 62895:2017 HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION - CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320 KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS
    BS EN 50441-4:2012 Cables for indoor residential telecommunication installations Cables up to 1 200 MHz. Grade 3
    14/30290103 DC : 0 BS EN 62895 - HIGH VOLTAGE DIRECT CURRENT (HVDC) POWER TRANSMISSION CABLES WITH EXTRUDED INSULATION AND THEIR ACCESSORIES FOR RATED VOLTAGES UP TO 320KV FOR LAND APPLICATIONS - TEST METHODS AND REQUIREMENTS
    BS EN 50525-2-11:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750V (U0/U) Cables for general applications. Flexible cables with thermoplastic PVC insulation
    08/30188821 DC : 0 BS EN 50525-2-82 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-82: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSS LINKED ELASTOMERIC INSULATION FOR DECORATIVE CHAINS
    I.S. EN 60702-1:2002 MINERAL INSULATED CABLES AND THEIR TERMINATIONS WITH A RATED VOLTAGE NOT EXCEEDING 750 V - PART 1: CABLES
    I.S. EN 50575:2014 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
    17/30361394 DC : 0 BS EN 50174-1 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 1: INSTALLATION SPECIFICATION AND QUALITY ASSURANCE
    I.S. EN 50525-2-81:2011 ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V (U[0]/U) - PART 2-81: CABLES FOR GENERAL APPLICATIONS - CABLES WITH CROSSLINKED ELASTOMERIC COVERING FOR ARC WELDING
    UNE-EN 50264-3-2:2010 Railway applications - Railway rolling stock power and control cables having special fire performance -- Part 3-2: Cables with crosslinked elastomeric insulation with reduced dimensions - Multicore cables
    08/30188793 DC : 0 BS EN 50525-2-31 - ELECTRIC CABLES - LOW VOLTAGE ENERGY CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2-31: CABLES FOR GENERAL APPLICATIONS - SINGLE CORE NON-SHEATHED CABLES WITH THERMOPLASTIC PVC INSULATION
    BS EN 50525-3-31:2011 Electric cables. Low voltage energy cables of rated voltages up to and including 450/750 V (U0/U) Cables with special fire performance. Single core non-sheathed cables with halogen-free thermoplastic insulation, and low emission of smoke
    08/30159870 DC : DRAFT APR 2008 BS EN 60800 - HEATING CABLES WITH A RATED VOLTAGE OF 300/500 V FOR COMFORT HEATING AND PREVENTION OF ICE FORMATION
    BS EN 60332-1-1 : 2004