Vorwort
Einleitung
1 Anwendungsbereich
2 Normative Verweisungen
3 Definitionen, Symbole und Abkürzungen
3.1 Definitionen
3.2 Symbole
4 Werkstoff
4.1 Formstückwerkstoff
4.2 Mindestfestigkeit (MRS-Wert)
4.3 Bezeichnung des Formstückwerkstoffes
4.4 Festigkeitseigenschaften des Spritzgusswerkstoffes
4.5 Festigkeitseigenschaften der aus Rohren
hergestellten Formstücke
5 Allgemeine Eigenschaften
5.1 Beschaffenheit
5.2 Farbe
5.3 Lichtundurchlässigkeit
6 Geometrische Eigenschaften
6.1 Messung der Masse
6.2 Nenndurchmesser
6.3 Formstücke für Klebverbindungen
6.4 Bundbuchsen und Flansche
6.5 Formstücke für elastomere Dichtringverbindungen
6.6 Zugfeste Doppelmuffen mit elastomeren Dichtringen
7 Klassifizierung und Betriebsbedingungen
7.1 Klassifizierung
7.2 Berechnung des zulässigen Betriebsdruckes
PFA für Wasser bis 45 grad C
8 Mechanische Eigenschaften
8.1 Widerstandsfähigkeit gegen Innendruck von
Formstücken oder Teilen davon
8.2 Verformung durch Quetschen
9 Physikalische Eigenschaften
10 Chemische Eigenschaften
11 Dichtringe
12 Klebstoffe
13 Anforderungen an die Verbindungen und die
Gebrauchstauglichkeit des Rohrleitungssystems
14 Kennzeichnung
14.1 Allgemeines
14.2 Mindest-Kennzeichnung der Formstücke und Flansche
14.3 Zusätzliche Kennzeichnung
Anhang A (normativ) Formstücke mit Inch-Massen
Anhang B (informativ) Literaturhinweise
This standard is included in DIN Handbook 62-2, 62 CD and 190. Defines the characteristics of fittings made from unplasticized poly(vinyl chloride) (PVC-U) for piping systems used in the field of water supply.
| DevelopmentNote |
Supersedes DIN 19532 (08/2000)
|
| DocumentType |
Standard
|
| Pages |
48
|
| PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| BS EN 1452-3 : 2000 | Identical |
| NBN EN 1452-3 : 2000 | Identical |
| NF EN 1452-3 : 1999 | Identical |
| I.S. EN 1452-3:1999 | Identical |
| EN 1452-3 : 1999 | Identical |
| NEN EN 1452-3 : 1999 | Identical |
| NS EN 1452-3 : 1999 | Identical |
| UNE-EN 1452-3:2000 | Identical |
| DIN HDBK 62 CD : 7ED 2004 | WASSERVERSORGUNG 2 - GUSS-, KUNSTSTOFF-, STAHLBETON- UND STAHLROHRE FUER WASSERLEITUNGEN |
| DIN HDBK 62-2 : 8ED 2010 |
| EN ISO 12162:2009 | Thermoplastics materials for pipes and fittings for pressure applications - Classification, designation and design coefficient (ISO 12162:2009) |
| EN 1452-5 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 5: FITNESS FOR PURPOSE OF THE SYSTEM |
| ENV 1452-6 : DRAFT 2001 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 6: GUIDANCE FOR INSTALLATION |
| ENV 1452-7:2000 | Plastics piping systems for water supply - Unplasticized poly(vinyl chloride) (PVC-U) - Part 7: Guidance for the assessment of conformity |
| EN 802:1994 | Plastics piping and ducting systems - Injection-moulded thermoplastics fittings for pressure piping systems - Test method for maximum deformation by crushing |
| EN 763 : 1994 | PLASTICS PIPING AND DUCTING SYSTEMS - INJECTION MOULDED THERMOPLASTICS FITTINGS - TEST METHOD FOR VISUALLY ASSESSING EFFECTS OF HEATING |
| EN 578 : 1993 | PLASTICS PIPING SYSTEMS - PLASTICS PIPES AND FITTINGS - DETERMINATION OF THE OPACITY |
| ISO 12092:2000 | Fittings, valves and other piping system components made of unplasticized poly(vinyl chloride) (PVC-U), chlorinated poly(vinyl chloride) (PVC-C), acrylonitrile-butadiene-styrene (ABS) and acrylonitrile-styrene-acrylester (ASA) for pipes under pressure — Resistance to internal pressure — Test method |
| EN ISO 13783:1997 | Plastics piping systems - Unplasticized poly(vinyl chloride) (PVC-U) end-load-bearing double socket joints - Test method for leaktightness and strength while subjected to bending and internal pressure (ISO 13783:1997) |
| ISO 2536:1974 | Unplasticized polyvinyl chloride (PVC) pressure pipes and fittings, metric series — Dimensions of flanges |
| EN 921:1994/AC:1995 | PLASTICS PIPING SYSTEMS - THERMOPLASTICS PIPES - DETERMINATION OF RESISTANCE TO INTERNAL PRESSURE AT CONSTANT TEMPERATURE |
| EN 727:1994 | Plastics piping and ducting systems - Thermoplastics pipes and fittings - Determination of Vicat softening temperature (VST) |
| EN 1452-4 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 4: VALVES AND ANCILLARY EQUIPMENT |
| EN 1452-1 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 1: GENERAL |
| EN 1452-2 : 1999 | PLASTICS PIPING SYSTEMS FOR WATER SUPPLY - UNPLASTICIZED POLY(VINYL CHLORIDE) (PVC-U) - PART 2: PIPES |
| EN 12107 : 1997 | PLASTICS PIPING SYSTEM - INJECTION MOULDED THERMOPLASTICS FITTINGS, VALVES AND ANCILLARY EQUIPMENT - DETERMINATION OF THE LONG-TERM HYDROSTATIC STRENGTH OF THERMOPLASTICS MATERIALS FOR INJECTION MOULDING OF PIPING COMPONENTS |
| ISO/TR 9080:1992 | Thermoplastics pipes for the transport of fluids — Methods of extrapolation of hydrostatic stress rupture data to determine the long-term hydrostatic strength of thermoplastics pipe materials |
Access your standards online with a subscription
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.