• Shopping Cart
    There are no items in your cart

DIN EN 15193:2008-01

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

ENERGY PERFORMANCE OF BUILDINGS - ENERGY REQUIREMENTS FOR LIGHTING

Available format(s)

Hardcopy , PDF

Language(s)

English

Published date

01-01-2008

Superseded date

01-10-2017

€209.37
Excluding VAT
Summarise this standard

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Calculating energy used for lighting
  4.1 Total energy used for lighting
      4.1.1 Total estimated energy
      4.1.2 Total annual energy used for lighting
  4.2 Lighting Energy Numeric Indicator (LENI)
5 Metering
  5.1 General
  5.2 Load segregation
  5.3 Remote metering
6 Calculation of lighting energy in buildings
  6.1 Installed lighting power
      6.1.1 General
      6.1.2 Luminaire
      6.1.3 Luminaire power (P[i])
      6.1.4 Parasitic powers (P[ci] and P[ei])
  6.2 Calculation methods
      6.2.1 Quick method
      6.2.2 Comprehensive method
      6.2.3 Determination of constant illuminance factor F[c]
7 Benchmark of lighting energy requirements
8 Lighting design and practice
Annex A (informative) Metering of lighting circuit
Annex B (informative) Measurement method of total power of
        luminaires and associated parasitic power
      B.1 Introduction
      B.2 Test measurement of luminaire power during normal
           operation
      B.3 Standard test conditions
      B.4 Electrical measuring instruments
      B.5 Test luminaires
      B.6 Test voltage
      B.7 Luminaire power (P[i])
      B.8 Luminaire parasitic power with lamps off (P[pi])
      B.9 Emergency lighting luminaire parasitic input power
           (P[ei])
      B.10 Lighting controls standby parasitic power (P[ci])
      B.11 Default luminaire power for existing lighting
           installations
      B.12 Default parasitic energy for existing lighting
           installations
Annex C (informative) Determination of the daylight dependency
        factor F[D,n]
      C.1 General
      C.2 Building segmentation: Spaces benefiting from daylight
      C.3 Daylight supply
          C.3.1 Vertical fagades
          C.3.2 Rooflights
      C.4 Daylight dependent artificial lighting control, F[D,c]
      C.5 Monthly method
Annex D (informative) Determination of occupancy dependency
        factor F[o]
      D.1 Introduction
      D.2 Detailed determination of F[o]
      D.3 Motivation for the choice of F[o] functions
Annex E (informative) Determination of the constant illuminance
        factor F[c]
      E.1 Introduction
      E.2 Power for constant illuminance factor
      E.3 Constant illuminance factor (F[c])
Annex F (informative) Benchmark values and lighting design criteria
Annex G (informative) Default values
      G.1 The default values for annual operating hours relating
          to building type are given in Table G.1
Annex H (informative) Other considerations
      H.1 Individual dimming
      H.2 Algorithmic lighting
      H.3 Light pipes
      H.4 Lighting installations with scene setting
      H.5 Daylight guidance
          H.5.1 Vertical fagades
          H.5.2 Rooflights
Annex I (informative) List of Symbols
Bibliography
National Annex NA (informative) Comparison of calculation methods
                  used in Germany with those specified in this
                  European Standard

Describes the calculation methodology for the evaluation of the amount of energy used for indoor lighting inside the building and provides a numeric indicator for lighting energy requirements used for certification purposes.

DocumentType
Standard
Pages
82
PublisherName
German Institute for Standardisation (Deutsches Institut für Normung)
Status
Superseded

Standards Relationship
NS EN 15193 : 2007 AC 2010 Identical
NBN EN 15193 : 2008 COR 2010 Identical
I.S. EN 15193:2007 Identical
NF EN 15193 : 2007 Identical
NEN EN 15193 : 2007 C1 2010 Identical
BS EN 15193:2007 Identical
UNE-EN 15193:2008 Equivalent

€209.37