• DIN EN 15417:2006-11

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    GAS-FIRED CENTRAL HEATING BOILERS - SPECIFIC REQUIREMENTS FOR CONDENSING BOILERS WITH A NOMINAL HEAT INPUT GREATER THAN 70 KW BUT NOT EXCEEDING 1000 KW

    Available format(s):  Hardcopy, PDF

    Superseded date:  01-10-2014

    Language(s):  English

    Published date:  12-01-2013

    Publisher:  German Institute for Standardisation (Deutsches Institut für Normung)

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Classification of boilers
      4.1 Gases and categories
      4.2 Classification according to the mode of
          evacuation of the combustion products
      4.3 Classification according to operating conditions
          4.3.1 Gas condensing boiler
          4.3.2 Standard boiler
    5 Constructional requirements
      5.1 Materials in contact with condensate
      5.2 Removal of condensate
      5.3 Chemical composition of the condensate
      5.4 Control of the combustion products temperature
    6 Operational requirements
      6.1 General
      6.2 Verification of the nominal condensing output
      6.3 Formation of condensate
      6.4 Temperature of combustion products
      6.5 Combustion
      6.6 Useful efficiency
          6.6.1 General
          6.6.2 Useful at the nominal heat input
          6.6.3 Useful efficiency at part load
    7 Test methods
      7.1 General
      7.2 Verification of the nominal condensing output
      7.3 Formation of condensate
      7.4 Temperature of combustion products
      7.5 Combustion
          7.5.1 Normal conditions
          7.5.2 Condensate discharge blockage
      7.6 Useful efficiency
          7.6.1 General
          7.6.2 Useful efficiency at nominal heat input
          7.6.3 Useful efficiency at part load
    8 Marking
      8.1 Data plate
      8.2 Instructions
          8.2.1 Technical instructions for the installer
          8.2.2 Use and maintenance instructions for the
                user
    Annex A (normative) Correction for the determined
             efficiency in the low water temperature
             test of condensing boilers
    Annex ZA (informative) Clauses of this European standard
             addressing essential requirements or other
             provisions of EU Directives
    Bibliography

    Abstract - (Show below) - (Hide below)

    Determines gas-fired central heating boilers, which are declared by the manufacturer to be 'condensing boilers': - of types C (excluding appliances without a fan) and B; - using one or more gases corresponding to the three gas families; - for which the nominal heat input is greater than 70 kW but not exceeding 1000 kW.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 13836:2006 Gas fired central heating boilers - Type B boilers of nominal heat input exceeding 300 kW, but not exceeding 1 000 kW
    EN 656:1999/A1:2006 GAS-FIRED CENTRAL HEATING BOILERS - TYPE B BOILERS OF NOMINAL HEAT INPUT EXCEEDING 70 KW BUT NOT EXCEEDING 300 KW
    EN 437:2003+A1:2009 Test gases - Test pressures - Appliance categories
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective