    HIGH EFFICIENCY AIR FILTERS (EPA, HEPA AND ULPA) - PART 1: CLASSIFICATION, PERFORMANCE TESTING, MARKING

    Available format(s):  Hardcopy, PDF

    Superseded date:  07-10-2019

    Language(s):  English

    Published date:  01-01-2011

    Publisher:  German Institute for Standardisation (Deutsches Institut für Normung)

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Vorwort
    1 Anwendungsbereich
    2 Normative Verweisungen
    3 Definitionen, Symbole und Abkürzungen
      3.1 Definitionen
      3.2 Symbole und Abkürzungen
    4 Klassifikation
      4.1 Filtergruppen
      4.2 Filterklassen
    5 Anforderungen
      5.1 Allgemeines
      5.2 Werkstoffe
      5.3 Nennvolumenstrom
      5.4 Druckdifferenz
      5.5 Filtrationsleistung
    6 Prüfverfahren
      6.1 Prüfstände
      6.2 Prüfbedingungen
      6.3 Prüfaerosol
      6.4 Verfahrensübersicht
      6.5 Prüfverfahren
    7 Filterbeurteilung, Dokumentation
    8 Kennzeichnung

    Abstract - (Show below) - (Hide below)

    This standard is included in DIN Handbook 85.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes DIN 24184 and DIN 24183-1. (05/2001) DRAFT 2017 issued in July 2017. (07/2017)
    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Superseded

    Standards Referenced By This Book - (Show below) - (Hide below)

    KTA 1503.1 : 2016(R2017) MONITORING THE DISCHARGE OF RADIOACTIVE GASES AND AIRBORNE RADIOACTIVE PARTICULATES - PART 1: MONITORING THE DISCHARGE OF RADIOACTIVE MATTER WITH THE STACK EXHAUST AIR DURING SPECIFIED NORMAL OPERATION
    VDI 3677 Blatt 2:2004-02 Filtering separators - Depth fiber filters
    VDI/GVSS 6202 Blatt 1:2013-10 Contaminated buildings and technical installations - Demolition, refurbishing and maintenance
    VDI 4300 Blatt 11:2013-12 Measurement of indoor air pollution - Measurement strategies for determination of airborne particles in indoor environment - PM-fraction
    VDI 3678 Blatt 2:2010-12 Electrostatic precipitators - Process air and indoor air cleaning
    VDI 6032 Blatt 1:2015-05 Ventilation and indoor-air quality in vehicles - Hygiene requirements for ventilation and air-conditioning systems
    VDI 3491 Blatt 15:1996-12 Particulate matter measurement - Generation of test aerosols - Dilution systems with continuous volumetric flow
    VDI 6022 Blatt 5:2016-11 Ventilation and indoor-air quality - Avoidance of allergenic exposure - Requirements regarding the testing and evaluation of technical products and components affecting the indoor air
    VDI 6300 Blatt 1:2016-05 Genetic engineering operations in genetic engineering facilities - Guidance on safe operation of genetic engineering facilities
    VDI 2464 Blatt 3:2012-07 Ambient air measurement - Indoor air measurement - Measurement of polybrominated diphenylether, hexabromocyclododecane and hexabromobenzene by GC/MS
    VDI 2083 Blatt 3:2005-07 Cleanroom technology - Metrology and test methods
    DIN HDBK 85 : 11ED 2017 RAUMLUFTTECHNISCHE ANLAGEN VOB/STLB-BAU - VOB TEIL C: ATV DIN 18299, ATV DIN 18379
    DIN 18379:2016-09 GERMAN CONSTRUCTION CONTRACT PROCEDURES (VOB) - PART C: GENERAL TECHNICAL SPECIFICATIONS IN CONSTRUCTION CONTRACTS (ATV) - INSTALLATION OF AIR CONDITIONING SYSTEMS
    DIN EN 16913:2015-10 (Draft) AMBIENT AIR - STANDARD METHOD FOR MEASUREMENT OF NO[3][-], SO[4][2-], CL[-], NH[4][+], NA[+], K[+], MG[2+], CA[2+] IN PM2,5 AS DEPOSITED ON FILTERS

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 1822-5:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 5: Determining the efficiency of filter elements
    EN 1822-2:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 2: Aerosol production, measuring equipment, particle counting statistics
    EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
    ISO 14644-3:2005 Cleanrooms and associated controlled environments Part 3: Test methods
    ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
    EN 1822-3:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media
    EN 1822-4:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 4: Determining leakage of filter elements (scan method)
    EN 14799 : 2007 AIR FILTERS FOR GENERAL AIR CLEANING - TERMINOLOGY
    EN ISO 14644-3:2005 CLEANROOMS AND ASSOCIATED CONTROLLED ENVIRONMENTS - PART 3: TEST METHODS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective