DIN EN 50017 : 2000
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - POWDER FILLING 'Q'
12-01-2013
01-07-2008
Vorwort
1 Anwendungsbereich
2 Normative Verweisungen
3 Begriffe
4 Gehäuse
5 Anforderungen an das Füllgut
6 Abstände
7 Verwendung von Werkstoffen
8 Kabel- und Leitungseinführungen sowie
Durchführungen
9 Energiespeicher
10 Temperaturbegrenzung
11 Fehlerbedingungen
12 Typprüfungen
13 Stückprüfungen
14 Kennzeichnung
15 Betriebsanleitung
Anhang A (normativ) Versuchsanordnung für die
Isolationsprüfung des Füllgutes
Specifies requirements for construction, testing and marking of electrical apparatus in the kind of protection powder filling 'q', meant to be used in potentially explosive atmospheres of gas, vapour and mist. Includes the presence of combustible dusts.
| DevelopmentNote |
Applies in conjunction with DIN EN 50014. (03/2000)
|
| DocumentType |
Standard
|
| PublisherName |
Verband Deutscher Elektrotechniker
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| BS EN 50017:1998 | Identical |
| NEN EN 50017 : 1998 | Identical |
| EN 50017:1998 | Identical |
| NBN EN 50017 : 1999 | Identical |
| NF EN 50017 : 1999 | Identical |
| I.S. EN 50017:1999 | Identical |
| VDE 0170-4 : 2015 | Corresponds |
| UNE-EN 50017:1999 | Identical |
| DIN 40012-1:1984-05 | PROTECTION AGAINST EXPLOSION - MARKING OF ELECTRICAL EQUIPMENT - SIGNS AND PLATES |
| DIN EN 50303 : 2001-05 | GROUP 1, CATEGORY M1 EQUIPMENT INTENDED TO REMAIN FUNCTIONAL IN ATMOSPHERES ENDANGERED BY FIREDAMP AND/OR COAL DUST |
| VDI/VDE 2189 Blatt 3:1994-10 | Three-level stepping controllers - Methods of evaluation the performance |
| VDE 0166 : 81 AMD 1 87 | ELECTRICAL INSTALLATIONS AND APPARATUS THEREOF FOR USE IN ATMOSPHERES POTENTIALLY ENDANGERED BY EXPLOSIVE MATERIAL |
| VDE 0400-40-1 : 2000 AMD 1 2004 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
| VDE 0170-12-2 : 2001-05 | GROUP 1, CATEGORY M1 EQUIPMENT INTENDED TO REMAIN FUNCTIONAL IN ATMOSPHERES ENDANGERED BY FIREDAMP AND/OR COAL DUST |
| VDI/VDE 2184:2008-06 | Reliable operation and maintenance of field bus systems |
| VDE 0101 : 2000 | POWER INSTALLATIONS EXCEEDING 1 KV |
| DIN EN 61779-1 : 2001 AMD 11 2004 | ELECTRICAL APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
| DIN EN 50241-1 : 2000 AMD 1 2004 | SPECIFICATION FOR OPEN PATH APPARATUS FOR THE DETECTION OF COMBUSTIBLE OR TOXIC GASES AND VAPOURS - PART 1: GENERAL REQUIREMENTS AND TEST METHODS |
| DIN EN 50014 : 2000 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |
| DIN EN 50284 : 2000 | SPECIAL REQUIREMENTS FOR CONSTRUCTION, TEST AND MARKING OF ELECTRICAL APPARATUS OF EQUIPMENT GROUP II, CATEGORY 1 G |
| VDE 0170/0171-3 : 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - PRESSURIZED APPARATUS "P" |
| VDE 0118 SUPP 1 : 1998 | ERECTION OF ELECTRICAL INSTALLATIONS IN MINES - GUIDE FOR THE PREPARATION OF A TECHNICAL DOCUMENTATION IN THE SENSE OF THE MACHINE DIRECTIVE |
| DIN 57166 : 1981 | ELECTRICAL INSTALLATIONS AND EQUIPMENT FOR USE IN ATMOSPHERES POTENTIALLY ENDANGERED BY EXPLOSIVE MATERIAL |
| VDE 0400-6 : 2000 | GUIDE FOR THE SELECTION, INSTALLATION, USE AND MAINTENANCE OF APPARATUS FOR THE DETECTION AND MEASUREMENT OF FLAMMABLE GASES |
| DIN EN 50073 : 2000 | GUIDE FOR THE SELECTION, INSTALLATION, USE AND MAINTENANCE OF APPARATUS FOR THE DETECTION AND MEASUREMENT OF COMBUSTIBLE GASES OR OXYGEN |
| VDE 0636-10 : 2005 | |
| DIN VDE 0820-1 : 1992 | MINIATURE FUSES - PART 1: DEFINITIONS FOR MINIATURE FUSES AND GENERAL REQUIREMENTS FOR MINIATURE FUSE-LINK |
| VDE 0820-1 : 2015 | Miniature fuses Part 1: Definitions for miniature fuses and general requirements for miniature fuse-links (IEC 60127-1:2006 + A1:2011 + A2:2015); |
| EN 50020:2002 | Electrical apparatus for potentially explosive atmospheres - Intrinsic safety 'i' |
| DIN EN 60269-1 : 2015 | LOW-VOLTAGE FUSES - PART 1: GENERAL REQUIREMENTS (IEC 60269-1:2006 + A1:2009 + A2:2014) |
| DIN VDE 0470-1 : 1992 | |
| ISO 565:1990 | Test sieves — Metal wire cloth, perforated metal plate and electroformed sheet — Nominal sizes of openings |
| EN 50019:2000/corrigendum Apr. 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
| VDE 0170-6 : 2016 | EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015) |
| DIN ISO 565:1998-12 | TEST SIEVES - METAL WIRE CLOTH, PERFORATED METAL PLATE AND ELECTROFORMED SHEET - NOMINAL SIZES OF OPENINGS |
| DIN EN 50019 : 2001 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INCREASED SAFETY "E" |
| VDE 0304-3 : 1999 | FLAMMABILITY OF SOLID NON-METALLIC MATERIALS WHEN EXPOSED TO FLAME SOURCES - LIST OF TEST METHODS |
| IEC 60707:1999 | Flammability of solid non-metallic materials when exposed to flame sources - List of test methods |
| VDE 0170-7 : 2012 | EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY "I" (IEC 60079-11:2011 + COR.:2012) |
| ISO 1210:1992 | Plastics — Determination of the burning behaviour of horizontal and vertical specimens in contact with a small-flame ignition source |
| DIN VDE 0636-10 : 1992 | LOW-VOLTAGES FUSES; GENERAL REQUIREMENTS |
| DIN EN 50014 : 2000 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |
| VDE 0170-1 : 2014 | EXPLOSIONSGEFAEHRDETE BEREICHE - TEIL 0: BETRIEBSMITTEL - ALLGEMEINE ANFORDERUNGEN (IEC 60079-0:2011, MODIFIZIERT +COR.:2012+COR.:2013) |
| DIN EN 50020 : 2003 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - INTRINSIC SAFETY 'I' |
| EN 60529:1991/AC:2016-12 | DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015) |
| EN 50014:1997/A2:1999 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |