• DIN EN 50123-5 : 2003

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 5: SURGE ARRESTERS AND LOW-VOLTAGE LIMITERS FOR SPECIFIC USE IN D.C. SYSTEMS

    Available format(s): 

    Superseded date:  01-05-2012

    Language(s): 

    Published date:  12-01-2013

    Publisher:  German Institute for Standardisation (Deutsches Institut für Normung)

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Vorwort
    Einleitung
    1 Gemeinsamer Inhalt
       1.1 Anwendungsbereich
       1.2 Normative Verweisungen
    2 Überspannungsableiter mit nichtlinearen Widerständen
       und Funkenstrecken
       2.1 Allgemeines
       2.2 Definitionen
       2.3 Kennzeichnung
       2.4 Vorzugsbemessungswerte
       2.5 Anforderungen
       2.6 Allgemeine Prüfverfahren
       2.7 Stück- und Abnahmeprüfungen
       2.8 Typprüfungen
    3 Prüfung der künstlichen Verschmutzsung von
       Überspannungsableitern
    4 Metalloxid-Überspannungsableiter ohne Funkenstrecken
       4.1 Allgemeines
       4.2 Definitionen
       4.3 Kennzeichnung
       4.4 Vorzugsbemessungswerte
       4.5 Anforderungen
       4.6 Allgemeine Prüfverfahren
       4.7 Typprüfungen
       4.8 Stück- und Abnahmeprüfungen
    5 Niederspannungsbegrenzer für den besonderen Einsatz in
       Gleichstromanlagen
       5.1 Allgemeines
       5.2 Definitionen
       5.3 Kennzeichnung und Einteilung
       5.4 Vorzugsbernessungswerte
       5.5 Anforderungen
       5.6 Stück- und Abnahmeprüfungen
       5.7 Typprüfungen
    Anhang A (informativ) Typische Informationen, die bei
             Anfragen und Ausschreibungen anzugeben sind
       A.1 Mit der Anfrage anzugebende Informationen
       A.2 Im Angebot anzugebende Informationen

    Abstract - (Show below) - (Hide below)

    Specifies particular requirements for surge arresters for specific use in fixed installations of d.c. traction systems.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Superseded
    Superseded By

    Standards Referencing This Book - (Show below) - (Hide below)

    VDE 0675-1 : 2000 COR 1 2000 SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS
    DIN EN 60099-4 : 2015 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS (IEC 60099-4:2014)
    VDE 0675-4 : 2015 SURGE ARRESTERS - PART 4: METAL-OXIDE SURGE ARRESTERS WITHOUT GAPS FOR A.C. SYSTEMS (IEC 60099-4:2014)
    EN 60099-4:2014 Surge arresters - Part 4: Metal-oxide surge arresters without gaps for a.c. systems
    EN 60099-1:1994/A1:1999 SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS
    DIN EN 50163 : 2005 COR 2 2014 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
    DIN EN 50123-1 : 2003 COR 1 2004 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL
    EN 50125-2:2002/corrigendum:2010 RAILWAY APPLICATIONS - ENVIRONMENTAL CONDITIONS FOR EQUIPMENT - PART 2: FIXED ELECTRICAL INSTALLATIONS
    VDE 0115-102 : 2005 COR 2 2014 RAILWAY APPLICATIONS - SUPPLY VOLTAGES OF TRACTION SYSTEMS
    DIN EN 60099-1 : 2000 COR 1 2000 SURGE ARRESTERS - PART 1: NON-LINEAR RESISTOR TYPE GAPPED SURGE ARRESTERS FOR A.C. SYSTEMS
    VDE 0432-1 : 2011 HIGH-VOLTAGE TEST TECHNIQUES - PART 1: GENERAL DEFINITIONS AND TEST REQUIREMENTS
    DIN IEC 60060-1 : 1994 HIGH VOLTAGE TEST TECHNIQUES - GENERAL SPECIFICATIONS AND TEST REQUIREMENTS
    VDE 0115-300-1 : 2003 COR 1 2004 RAILWAY APPLICATIONS - FIXED INSTALLATIONS - D.C. SWITCHGEAR - PART 1: GENERAL
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective