• DIN EN 50131-2-2 : 2008

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 2-2: INTRUSION DETECTORS - PASSIVE INFRARED DETECTORS

    Available format(s): 

    Superseded date:  08-09-2018

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Verband Deutscher Elektrotechniker

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope
    2 Normative references
    3 Definitions and abbreviations
      3.1 Definitions
      3.2 Abbreviations
    4 Functional requirements
      4.1 Event Processing
      4.2 Detection
      4.3 Operational requirements
      4.4 Immunity to incorrect operation
      4.5 Tamper security
      4.6 Electrical requirements
      4.7 Environmental classification and conditions
    5 Marking, identification and documentation
      5.1 Marking and/or identification
      5.2 Documentation
    6 Testing
      6.1 General test conditions
      6.2 Basic detection test
      6.3 Walk testing
      6.4 Switch-on delay, time interval between signals and
           indication of detection
      6.5 Self tests
      6.6 Immunity to incorrect operation
      6.7 Tamper security
      6.8 Electrical tests
      6.9 Environmental classification and conditions
      6.10 Marking, identification and documentation
    Annexes
    Annex A (normative) Dimensions & requirements of the standardised
            test magnets
    Annex B (normative) General Testing Matrix
    Annex C (informative) Walk Test Diagrams
    Annex D (normative) Procedure for calculation of average
            temperature difference
    Annex E (informative) Basic detection target for the basic test
            of detection capability
    Annex F (informative) Equipment for walk test velocity control
    Annex G (informative) Immunity to visible and near infrared
            radiation - Notes on calibration of the light source
    Annex H (informative) Example list of small tools
    Annex I (informative) Test for resistance to re-orientation of
            adjustable mountings

    Abstract - (Show below) - (Hide below)

    Diese Europäische Norm gilt für in Gebäude installierte Passiv-Infrarotmelder und berücksichtigt die Sicherheitsgrade 1 bis 4 (siehe EN 50131-1), exklusiv oder nicht exklusiv verdrahtete oder drahtlose Melder und deckt die Umweltklassen I bis IV ab (siehe EN 50130-5). Diese Europäische Norm enthält keine Anforderungen an Passiv-Infrarotmelder, die für die Verwendung im Freien vorgesehen sind.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes DIN CLC/TS 50131-2-2. (09/2008) DRAFT 2018 issued in February 2018. (02/2018)
    Document Type Standard
    Publisher Verband Deutscher Elektrotechniker
    Status Superseded
    Superseded By
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective