DIN EN 50281-1-1 : 1999 AMD 1 2002
Withdrawn
A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.
ELECTRICAL APPARATUS FOR USE IN THE PRESENCE OF COMBUSTIBLE DUST - PART 1-1: ELECTRICAL APPARATUS PROTECTED BY ENCLOSURES - CONSTRUCTION AND TESTING
01-07-2007
12-01-2013
Foreword
Introduction
1 Scope
2 Normative references
3 Definitions
4 Requirements for all category 1 and 2 electrical
apparatus
5 Supplementary requirements for certain category 2
electrical apparatus
6 Requirements for all category 3 electrical apparatus
7 Supplementary requirements for certain category 3
electrical apparatus
8 Type verification and tests
9 Dust tightness test
10 Thermal tests for category 1, 2 and 3 electrical
apparatus
11 Marking
12 Examples of marking
13 Instructions
Defines the requirements for construction, design and testing of electrical apparatus. Applies to electrical apparatus protected by enclosure and temperature limitation to be used in areas where combustible dust may be present in quantities, which could cause a fire or explosion hazard.
DocumentType |
Standard
|
PublisherName |
Verband Deutscher Elektrotechniker
|
Status |
Withdrawn
|
Standards | Relationship |
NF EN 50281-1-1 : 2000 AMD 1 2003 | Identical |
NEN EN 50281-1-1 : 98 AMD 1 2002 | Identical |
I.S. EN 50281-1-1:1999 | Identical |
SN EN 50281-1-1 : 1998 AMD 1 2002 | Identical |
VDE 0170-15-1-1 : 1999 AMD 1 2002 | Corresponds |
EN 50281-1-1 : 98 AMD 1 2002 | Identical |
BS EN 50281-1-1:1999 | Identical |
VDI 2263 Blatt 8:2008-12 | Dust fires and dust explosions - Hazards - Assessment - Protective measures - Fire and explosion protection on elevators |
VDI 2263 Blatt 7:2010-07 | Dust fires and dust explosions - Hazards - assessment - protective measures - Dust fires and explosion protection in spraying and drying integrated equipment |
VDI 2263 Blatt 5.1:2014-10 | Dust fires and dust explosions - Hazards, assessment, protective measures - Explosion protection in fluid bed dryers - Hints and examples of operation |
DIN EN 50014 : 2000 | ELECTRICAL APPARATUS FOR POTENTIALLY EXPLOSIVE ATMOSPHERES - GENERAL REQUIREMENTS |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.