STATIONARY LEAD-ACID BATTERIES - GENERAL REQUIREMENTS AND METHODS OF TEST - PART 1: VENTED TYPES
01-07-2003
12-01-2013
Cooperating organizations
National foreword
Foreword
Section One - General
1. Scope
2. Object
Section Two - General requirements and definitions
3. Mechanical strength
4. Electrolyte levels
5. Definition - Electrolyte reserve
Section Three - Functional characteristics and specific
requirements
6. Capacity
7. Suitability for floating battery operation
8. Endurance
9. Charge retention
10. Short-circuit current and internal resistance
11. Accuracy of measuring instruments
12. Preparation of cells and batteries for testing
Section Five - Test methods
13. Capacity test
14. Test of suitability for floating battery operation
15. Endurance in discharge-charge cycles
16. Charge retention test
17. Short-circuit current and internal resistance test
18. Test sequence
Appendix A
Table AI - Typical stationary lead-acid battery
applications
Table AII - Typical types and construction of stationery
lead-acid batteries
Annex ZA (normative) Other international publications
quoted in this standard with the references of the
relevant European publications
National annex NA (informative) Committees responsible
National annex NB (informative) Cross-references
Specifies general requirements and the main characteristics together with corresponding test methods associated with all types and construction modes of lead-acid stationary batteries, excluding valve-regulated types. Applies to lead-acid cells and batteries which are meant for service in a fixed location and which are permanently connected to the load and to the d.c. power supply.
DevelopmentNote |
Partially supersedes DIN 43539-1 and DIN 43539-1 E. (12/2001) Supersedes DIN 43539-4. (03/2003)
|
DocumentType |
Standard
|
PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
SN EN 60896-1 : 1991 AMD 2 1992 | Identical |
I.S. EN 60896-1:1992 AMD 2 1993 | Identical |
IEC 60896-1:1987 | Identical |
BS EN 60896-1:1992 | Identical |
UNE EN 60896-1 : 1994 A2 1996 | Identical |
EN 60896-1:1991/A2:1992 | Identical |
NF EN 60896-1 : 93 AMD 2 95 | Identical |
VDE 0558-508 : 2001 | CENTRAL POWER SUPPLY SYSTEMS |
VDE 0101 : 2000 | POWER INSTALLATIONS EXCEEDING 1 KV |
VDE 0510-2 : 2001 | SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 2: STATIONARY BATTERIES |
DIN EN 50272-2 : 2001 | SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 2: STATIONARY BATTERIES |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.