    D.C. OR A.C. SUPPLIED ELECTRONIC STEP-DOWN CONVERTORS FOR FILAMENT LAMPS - GENERAL AND SAFETY REQUIREMENTS

    Available format(s): 

    Superseded date:  01-12-2001

    Language(s): 

    Published date:  12-01-2013

    Publisher:  German Institute for Standardisation (Deutsches Institut für Normung)

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Vorwort
    Einleitung
    HAUPTABSCHNITT 1 - ALLGEMEINE ANFORDERUNGEN
    1 Allgemeines
       1.1 Anwendungsbereich
       1.2 Normative Verweisungen
    2 Begriffe
    3 Allgemeine Anforderungen
    4 Allgemeines über Prüfungen
    5 Einteilung
    6 Aufschriften
    HAUPTABSCHNITT 2 - SICHERHEITS-ANFORDERUNGEN
    7 Anschlussklemmen
    8 Schutzleiteranschluss
    9 Aufbau
    10 Kriech- und Luftstrecken
    11 Schutz gegen zufällige Berührung aktiver Teile
    12 Feuchtebeständigkeit und Isolierung
    13 Spannungsfestigkeit
    14 Transformator-Erwärmung
    15 Anomale Bedingungen
    16 Fehlerbedingungen
    17 Schrauben, stromführende Teile und Verbindungen
    18 Wärme- und Feuerbeständigkeit
    19 Beständigkeit gegen Korrosion
    Anhang A (normativ) Prüfung zur Bestimmung, ob ein
              leitfähiges Teil als aktives Teil anzusehen ist,
              das einen elektrischen Schlag verursachen kann
    Anhang B (normativ) Besondere Anforderungen für gleich-
              oder wechselstromversorgte elektronische Konverter
              für Glühlampen mit Schutzvorrichtung gegen
              Überhitzung
    Anhang C (normativ) Besondere zusätzliche Anforderungen
              für unabhängige gleich- oder wechselstromversorgte
              elektronische Konverter mit Schutzkleinspannung
              (SELV) für Glühlampen
    Anhang ZA (normativ) Andere in dieser Norm zitierte
              internationale Publikationen mit den Verweisungen
              auf die entsprechenden europäischen Publikationen

    Abstract - (Show below) - (Hide below)

    Specifies safety and general requirements for d.c. or a.c. electronic step-down convertors for filament lamps generally operating with frequency deviating from the supply frequency. Deals with type tests; does not deal with testing individual convertors during production.

    General Product Information - (Show below) - (Hide below)

    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    VDE 0711-2-23 : 2001 LUMINAIRES - PART 2-23: PARTICULAR REQUIREMENTS - EXTRA LOW-VOLTAGE LIGHTING SYSTEMS FOR FILAMENT LAMPS
    VDE 0711-223 : 1997 LUMINAIRES - PART 2: PARTICULAR REQUIREMENTS - SECTION 23: EXTRA LOW-VOLTAGE LIGHTING SYSTEMS FOR FILAMENT LAMPS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60730-2-3:2006 Automatic electrical controls for household and similar use - Part 2-3: Particular requirements for thermal protectors for ballasts for tubular fluorescent lamps
    VDE 0631-2-3 : 2008-06 AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-3: PARTICULAR REQUIREMENTS FOR THERMAL PROTECTORS FOR BALLASTS FOR TUBULAR FLUORESCENT LAMPS
    IEC 60695-2-1:1991 Fire hazard testing - Part 2: Test methods - Section 1: Glow-wire test and guidance
    EN 60065:2014/AC:2017-01 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014/COR2:2016)
    DIN VDE 0551-1 : 1989 ISOLATING TRANSFORMERS AND SAFETY ISOLATING TRANSFORMERS - REQUIREMENTS
    IEC 60364-4-41:2005+AMD1:2017 CSV Low voltage electrical installations - Part 4-41: Protection for safety - Protection against electric shock
    VDE 0821 : 2017 THERMAL-LINKS - REQUIREMENTS AND APPLICATION GUIDE (IEC 60691:2015 + COR1:2016)
    DIN EN 60598-1 : 2015 COR 1 2016 LUMINAIRES - PART 1: GENERAL REQUIREMENTS AND TESTS (IEC 60598-1:2014, MODIFIED)
    DIN VDE 0470-1 : 1992
    VDE 0711-1 : 2015 COR 1 2016 LEUCHTEN - TEIL 1: ALLGEMEINE ANFORDERUNGEN UND PRUEFUNGEN (IEC 60598-1:2014, MODIFIZIERT)
    IEC 60269-2:2013+AMD1:2016 CSV Low-voltage fuses - Part 2: Supplementary requirements for fuses for use by authorized persons (fuses mainly for industrial application) - Examples of standardized systems of fuses A to K
    EN 60691:2016 Thermal-links - Requirements and application guide
    DIN VDE 0821 : 1988
    DIN EN 60695-2-2 : 1996 FIRE HAZARD TESTING - PART 2: TEST METHODS - SECTION 2: NEEDLE-FLAME TEST
    IEC 60598-2-6:1994 Luminaires - Part 2: Particular requirements - Section 6: Luminaires with built-in transformers for filament lamps
    DIN EN 60051-1 : 1999 DIRECT ACTING INDICATING ANALOGUE ELECTRICAL MEASURING INSTRUMENTS AND THEIR ACCESSORIES - PART 1: DEFINITIONS AND GENERAL REQUIREMENTS COMMON TO ALL PARTS (IEC 60051-1:2016)
    VDE 0301-1 : 2008 ELECTRICAL INSULATION - THERMAL EVALUATION AND DESIGNATION
    IEC 61047:2004 DC or AC supplied electronic step-down convertors for filament lamps - Performance requirements
    DIN EN 61047 : 2005 DC OR AC SUPPLIED ELECTRONIC STEP-DOWN CONVERTORS FOR FILAMENT LAMPS - PERFORMANCE REQUIREMENTS
    DIN EN 60730-2-3 : 2008-06 AUTOMATIC ELECTRICAL CONTROLS FOR HOUSEHOLD AND SIMILAR USE - PART 2-3: PARTICULAR REQUIREMENTS FOR THERMAL PROTECTORS FOR BALLASTS FOR TUBULAR FLUORESCENT LAMPS
    VDE 0551-1 : 1989 ISOLATING TRANSFORMERS AND SAFETY ISOLATING TRANSFORMERS - REQUIREMENTS
    IEC 60085:2007 Electrical insulation - Thermal evaluation and designation
    DIN IEC 60085 : 1993 THERMAL EVALUATION AND CLASSIFICATION OF ELECTRICAL INSULATION
    DIN EN 60920 : 1993 AMD 11 BALLASTS FOR TUBULAR FLUORESCENT LAMPS - GENERAL AND SAFETY REQUIREMENTS
    VDE 0100-410 : 2007 LOW-VOLTAGE ELECTRICAL INSTALLATIONS - PART 4-41: PROTECTION FOR SAFETY - PROTECTION AGAINST ELECTRIC SHOCK
    DIN IEC 60317-1:2009-06 (Draft) SPECIFICATIONS FOR PARTICULAR TYPES OF WINDING WIRES - PART 1: POLYVINYL ACETAL ENAMELLED ROUND COPPER WIRE, CLASS 105
    EN 60598-2-6:1994/A1:1997 LUMINAIRES - PART 2: PARTICULAR REQUIREMENTS - SECTION 6: LIMINAIRES WITH BUILT-IN TRANSFORMERS OR CONVERTERS FOR FILAMENT LAMPS
    DIN VDE 0711-206 : 1991 LEUCHTEN; TEIL 2: BESONDERE ANFORDERUNGEN; HAUPTABSCHNITT SECHS: LEUCHTEN MIT EINGEBAUTEN TRANSFORMATOREN FUER GLUEHLAMPEN
    HD 566 : 200S1 THERMAL EVALUATION AND CLASSIFICATION OF ELECTRICAL INSULATION
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60269-3:2010+AMD1:2013 CSV Low-voltage fuses - Part 3: Supplementary requirements for fuses foruse by unskilled persons (fuses mainly for household or similar applications) - Examples of standardized systems of fuses A to F
    VDE 0711-206 : 95 AMD 1 97 LUMINAIRES - PART 2: PARTICULAR REQUIREMENTS; SECTION 6: LUMINAIRES WITH BUILT-IN TRANSFORMERS FOR FILAMENT LAMPS
    IEC 60691:2015 Thermal-links - Requirements and application guide
    DIN EN 60249-1:1994-05 BASE MATERIALS FOR PRINTED CIRCUITS - PART 1: TEST METHODS
    VDE 0712-10 : 93 AMD 11 2000 BALLASTS FOR TUBULAR FLUORESCENT LAMPS; GENERAL AND SAFETY REQUIREMENTS
    IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
    DIN EN 60065 : 2015 COR 1 2016 AUDIO, VIDEO AND SIMILAR ELECTRONIC APPARATUS - SAFETY REQUIREMENTS (IEC 60065:2014, MODIFIED)
    HD 193 : 200S2 VOLTAGE BANDS FOR ELECTRICAL INSTALLATIONS OF BUILDINGS
    VDE 0471-2-1 : 84 DRAFT 92 FIRE HAZARD TESTING; TEST METHODS; GLOW WIRE TEST AND GUIDANCE
    DIN EN 60357:2011-09 TUNGSTEN HALOGEN LAMPS (NON-VEHICLE) - PERFORMANCE SPECIFICATIONS (IEC 60357:2002, MODIFIED + A1:2006, MODIFIED + A2:2008 + A3:2011)
    VDE 0712-25 : 2005 DC OR AC SUPPLIED ELECTRONIC STEP-DOWN CONVERTORS FOR FILAMENT LAMPS - PERFORMANCE REQUIREMENTS
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    HD 243 : S12 GRAPHICAL SYMBOLS FOR USE ON EQUIPMENT - INDEX, SURVEY AND COMPILATION OF THE SINGLE SHEETS
    VDE 0471-2-2 : 1996 FIRE HAZARD TESTING - PART 2: TEST METHODS; SECTION 2: NEEDLE-FLAME TEST
    IEC 60920:1990 Ballasts for tubular fluorescent lamps - General and safety requirements