• DIN EN 61315:2006-09

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    CALIBRATION OF FIBRE-OPTIC POWER METERS

    Available format(s):  Hardcopy, PDF

    Superseded date:  01-06-2020

    Language(s):  German

    Published date:  01-01-2006

    Publisher:  German Institute for Standardisation (Deutsches Institut für Normung)

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    SECTION 1: GENERAL
    1.1 Introduction
    1.2 Scope
    1.3 Normative references
    SECTION 2: BASIS OF CALIBRATIONS
    2.1 Definitions
    2.2 Mathematical basis
          2.2.1 Deviations and correction factors
          2.2.2 Systematic uncertainties
          2.2.3 Random uncertainties
          2.2.4 Accumulation of uncertainties
          2.2.5 Reporting
    2.3 General advice for accurate measurements and
          calibrations
          2.3.1 Organization
          2.3.2 Calibration methods and procedure
          2.3.3 Advice for measurements and calibrations
          2.3.4 Recommendations to customers
    SECTION 3: CALIBRATION AT REFERENCE CONDITIONS
    Calibration at reference conditions
          3.1.1 Establishing the reference conditions
          3.1.2 Transfer and correction factor
          3.1.3 Uncertainty at reference conditions
    3.2 Transfer-related correction factors and uncertainty
          3.2.1 Transfer-related correction factors and
                  uncertainties caused by the parent meter
                  3.2.1.1 Ageing (transfer-related correlation
                            factor and uncertainty of the
                            parent meter due to ageing)
                  3.2.1.2 Temperature dependence (transfer-
                            related correction factor and
                            uncertainty of the parent meter
                            due to temperature dependence
                  3.2.1.3 Nonlinearity (transfer-related
                            correction factor and uncertainty
                            of the parent meter due to
                            nonlinearity)
                  3.2.1.4 Dependence on beam geometry (transfer-
                            related correction factor and
                            uncertainty of the parent meter due
                            to beam geometry)
                  3.2.1.5 Dependence on multiple reflections
                            (transfer-related correction factor
                            and uncertainty of the parent meter
                            due to multiple reflections)
                  3.2.1.6 Wavelength dependence (transfer-
                            related correction factor and
                            uncertainty of the parent meter due
                            to wavelength dependence)
                  3.2.1.7 Dependence on spectral bandwidth
                            (transfer-related correction factor
                            and uncertainty of the parent meter
                            due to dependence on spectral
                            bandwidth)
                  3.2.1.8 Other dependencies (transfer-related
                            correction factor and uncertainty
                            of the parent meter due to other
                            dependences)
                  3.2.1.9 Dependence on state of polarization
          3.2.2 Transfer-related uncertainties caused by the
                  test meter
                  3.2.2.1 Temperature dependence (transfer-
                            uncertainty of the test meter due
                            to temperature dependences)
                  3.2.2.2 Dependence on beam geometry (transfer
                            uncertainty of the test meter due to
                            to beam geometry)
                  3.2.2.3 Dependence on multiple reflections
                            (transfer uncertainty of the test
                            meter due to multiple reflections)
                  3.2.2.4 Wavelength dependence (transfer
                            uncertainty of the test meter due
                            to wavelength dependence)
                  3.2.2.5 Dependence on spectral bandwidth
                            (transfer uncertainty of the test
                            meter due to spectral bandwith
                  3.2.2.6 Dependence on state of polarization
                            (transfer uncertainty of the test
                            meter due to dependence on the
                            state of polarization)
                  3.2.2.7 Other dependences (transfer
                            uncertainties of the test meter due
                            to other dependences)
          3.2.3 Corrections and systematic uncertainties due
                  to extension
          3.2.4 Other corrections and systematic uncertainties
          3.2.5 Random uncertainty of comparison
          3.2.6 Other random uncertainties
    3.3 Documentation
          3.3.1 Specifications
          3.3.2 Traceability information
    SECTION 4: CALIBRATION FOR OPERATING CONDITIONS
    4.1 Determining the total uncertainty
    4.2 Determining the operational uncertainty
          4.2.1 Operational dependences and uncertainties
                  4.2.1.1 Ageing
                  4.2.1.2 Temperature dependence
                  4.2.1.3 Nonlinearity
                  4.2.1.4 Dependence on the type of fibre or
                            on the beam geometry
                  4.2.1.5 Dependence on the connector-adaptor
                            combination
                  4.2.1.6 Wavelength dependence
                  4.2.1.7 Dependence on the spectral bandwidth
                  4.2.1.8 Other dependences
    4.3 Specifications
    Figures
    1 Systematic uncertainty, deviation and correction factor
        and how to replace the latter by an appropriately
        larger uncertainty
    2 Measurement setup for sequential, fibre-based calibration
    3 Example of a calibration chain and of the accumulation
        of uncertainties
    4 Calculation of the test meter uncertainty at
        reference conditions
    5 Change of condition and tolerance band as cause of
        transfer-related deviation and uncertainty of the
        parent meter
    6 Determining and recording an operational uncertainty
    7 Possible subdivision of the optical reference plane into
        10 x 10 squares, for the measurement of the spatial
        response
    8 Forms that guide through the calibration at reference
        conditions of section 3
    9 Forms that guide through the calibration for operating
        conditions of section 4
    Annexes
    A Forms and worksheets
    B Bibliographic references
    ZA (normative) Normative references to international
        publications with their corresponding European
        publications

                                             

                            
             

    Abstract - (Show below) - (Hide below)

    Applies to instruments measuring radiant power emitted from sources which are typical for the fibre-optic communications industry.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes DIN IEC 61315. (09/2006) DRAFT 2017 issued in January 2017. (01/2017)
    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Superseded
    Superseded By
    Supersedes
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective