DIN EN 858-2:2003-10
Current
The latest, up-to-date edition.
SEPARATOR SYSTEMS FOR LIGHT LIQUIDS (E.G. OIL AND PETROL) - PART 2: SELECTION OF NOMINAL SIZE, INSTALLATION, OPERATION AND MAINTENANCE
Hardcopy , PDF
German, English
01-10-2003
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Determination of type and size of separator systems
4.1 General
4.2 Components of separator systems, their combination
and application
4.2.1 General
4.2.2 Bypass separators
4.2.3 Classes of separators
4.3 Sizing of separators
4.3.1 General
4.3.2 Factors
4.3.3 Combined drainage of rainwater and wastewater
4.3.4 Wastewater
4.3.5 Rainwater flow rate
4.3.6 Spillages
4.3.7 Quantity of light liquid
4.3.8 Special cases
4.4 Sludge traps
5 Installation
5.1 Limitations
5.2 Retention of light liquid
5.3 Automatic warning devices and electrical devices
5.4 Drainage to and from separator systems
5.5 Place of installation
5.6 Protection against escape of light liquids
5.7 Connection to the drainage system
6 Operation, inspection and maintenance
Annex A (informative) Density factor f[d] for
particular light liquids and combination of
components
Annex B (informative) Configuration and application of
separator systems
Bibliography
Applies to separator systems used to separate hydrocarbons of mineral origin from wastewater.
| DevelopmentNote |
Together with DIN 1999-100 and DIN EN 858-1 supersedes DIN 1999-1, -2, -3, -4, -5 and -6. (10/2003) Applies in conjunction with DIN EN 858-1 issue 05-2001 and DIN 1999-100 issue 10-2003. (11/2003)
|
| DocumentType |
Standard
|
| Pages |
22
|
| PublisherName |
German Institute for Standardisation (Deutsches Institut für Normung)
|
| Status |
Current
|
| Supersedes |
| Standards | Relationship |
| I.S. EN 858-2:2003 | Identical |
| NF EN 858-2 : 2003 | Identical |
| EN 858-2:2003 | Identical |
| NBN EN 858-2 : 2003 | Identical |
| BS EN 858-2:2003 | Identical |
| NEN EN 858-2 : 2003 | Identical |
| NS EN 858-2 : 1ED 2003 | Identical |
| UNE-EN 858-2:2003 | Identical |