• DIN VDE 0281-7 : 2001

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - SINGLE CORE NON-SHEATHED CABLES FOR INTERNAL WIRING FOR CONDUCTOR TEMPERATURE OF 90 DEGREE C POUR FILERIE INTERNE

    Available format(s): 

    Superseded date:  01-01-2012

    Language(s): 

    Published date:  12-01-2013

    Publisher:  German Institute for Standardisation (Deutsches Institut für Normung)

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 Anwendungsbereich
    2 Verdrahtungsleitung für die innere Verdrahtung mit
      einer höchstzulässigen Temperatur am Leiter von 90
      grad C (300/500 V)
      2.1 Bauartkurzzeichen
      2.2 Nennspannung
      2.3 Aufbau
      2.4 Prüfungen
      2.5 Ursprungskennzeichnung und Kennzeichnung für die
          höchstzulässige Leitertemperatur
      2.6 Hinweise für die Verwendung (informativ)
    3 Aderleitung für die innere Verdrahtung mit einer
      höchstzulässigen Temperatur am Leiter von 90 grad C
      (450/750 V)
      3.1 Bauartkurzzeichen
      3.2 Nennspannung
      3.3 Aufbau
      3.4 Prüfungen
      3.5 Ursprungskennzeichnung und Kennzeichnung für die
          höchstzulässige Leitertemperatur
      3.6 Hinweis für die Verwendung (informativ)
    Anhang A (normativ) Normative Verweisungen
    Anhang B (informativ) Literaturhinweise

    Abstract - (Show below) - (Hide below)

    Dieser Teil (Teil 7) des HD enthält die besonderen Bestimmungen für PVC-isolierte, einadrige, nicht-ummantelte Leitungen mit Nennspannungen U[0]/U bis 450/750 V für die innere Verdrahtung von elektrischen Betriebsmitteln mit erhöhter Betriebstemperatur. Die erhöhte Temperatur kann entweder durch eine hohe Umgebungstemperatur und/oder die Wärmeentwicklung des Gerätes verursacht sein. Alle Leitungen müssen mit den entsprechenden Anforderungen des Teiles 1 und mit den besonderen Anforderungen in diesem Teil übereinstimmen. ANMERKUNG Die Aussenmasse der Leitungen nach diesem Teil des HD 21 sind in Übereinstimmung mit EN 60719 berechnet worden.

    General Product Information - (Show below) - (Hide below)

    Development Note Supersedes DIN VDE 0281-102 and DIN VDE 0281-108. (03/2003)
    Document Type Standard
    Publisher German Institute for Standardisation (Deutsches Institut für Normung)
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    DIN VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
    VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
    VDE 0160 : 1998-04 ELECTRONIC EQUIPMENT FOR USE IN POWER INSTALLATIONS
    VDE 0281-9 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 9: SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES

    Standards Referencing This Book - (Show below) - (Hide below)

    DIN EN 60811-1-4 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 1-4: GENERAL APPLICATION - TESTS AT LOW TEMPERATURE
    EN 60719:1993 Calculation of the lower and upper limits for the average outer dimensions of cables with circular copper conductors and of rated voltages up to and including 450/750 V
    VDE 0281-11 : 2003 CONDUCTEURS ET CABLES ISOLES AU POLYCHLORURE DE VINYLE, DE TENSION ASSIGNEE AU PLUS EGALE A 450/750 V - CABLES POUR LUMINAIRES
    DIN EN 60811-1-2 : 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 2: THERMAL AGEING METHODS
    VDE 0473-811-1-2 : 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 2: THERMAL AGEING METHODS
    DIN VDE 0281-13 : 2003 POLYVINYL CHLORIDE INSULATED CABLES FOR RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 13: OIL RESISTANT PVC SHEATHED CABLES WITH TWO OR MORE CONDUCTORS
    VDE 0281-1 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 1: GENERAL REQUIREMENTS
    VDE 0473-811-3-1 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - METHODS SPECIFIC TO PVC COMPOUNDS - PRESSURE TEST AT HIGH TEMPERATURE, TEST FOR RESISTANCE TO CRACKING
    VDE 0473-811-1-4 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION; SECTION 4: TEST AT LOW TEMPERATURE
    DIN VDE 0298-300 : 2009 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
    VDE 0281-12 : 2003 CONDUCTEURS ET CABLES ISOLES AU POLYCHLORURE DE VINYLE, DE TENSION ASSIGNEE AU PLUS EGALE A 450/750 V - CABLES SOUPLES RESISTANT A LA CHALEUR
    DIN VDE 0281-10 : 2003 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 10: EXTENSIBLE LEADS
    DIN VDE 0281-11 : 2003 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 11: CABLES FOR LUMINARIES
    DIN EN 60811-3-1 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 3-1: METHODS SPECIFIC TO PVC COMPOUNDS - PRESSURE TEST AT HIGH TEMPERATURE, TEST FOR RESISTANCE TO CRACKING
    DIN VDE 0295 : 1992 CONDUCTORS OF CABLES, WIRES AND FLEXIBLE CORDS FOR POWER INSTALLATION
    DIN EN 60811-1-1 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-1: GENERAL APPLICATION - MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TEST FOR DETERMINING THE MECHANICAL PROPERTIES
    VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
    VDE 0295 : 2005 Conductors of insulated cables (IEC 60228:2004); German version EN 60228:2005 + Corrigendum:2005
    DIN VDE 0281-12 : 2003 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 12: HEAT-RESISTANT FLEXIBLE CABLES (CORDS)
    VDE 0298-300 : 2009 LEITFADEN FUER DIE VERWENDUNG HARMONISIERTER NIEDERSPANNUNGSSTARKSTROMLEITUNGEN
    HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
    DIN VDE 0281-5 : 2002 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - FLEXIBLE CABLES (CORDS)
    DIN VDE 0281-2 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 2: TEST METHODS
    VDE 0482-265-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME
    VDE 0281-2 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 2: TEST METHODS
    VDE 0473-811-1-1 : 2002 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1-1: GENERAL APPLICATION; MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS; TEST FOR DETERMINING THE MECHANICAL PROPERTIES
    VDE 0473-811-3-2 : 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 3-2: METHODS SPECIFIC TO PVC COMPOUNDS - LOSS OF MASS TEST, THERMAL STABILITY TEST
    HD 516 S2:1997/A2:2008 GUIDE TO USE OF LOW VOLTAGE HARMONIZED CABLES
    DIN EN 60811-3-2 : 2004 INSULATING AND SHEATHING MATERIALS OF ELECTRIC AND OPTICAL CABLES - COMMON TEST METHODS - PART 3-2: METHODS SPECIFIC TO PVC COMPOUNDS - LOSS OF MASS TEST - THERMAL STABILITY TEST
    VDE 0281-9 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 9: SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES
    DIN VDE 0281-8 : 2000 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
    VDE 0281-8 : 2000 POLYVINYL CHLORIDE INSULATED CABLES OF NOMINAL VOLTAGES UP TO AND INCLUDING 450/750 V - PART 8: SINGLE CORE NON-SHEATHED CABLES FOR DECORATIVE CHAINS
    DIN EN 60719 : 1994 CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V
    DIN VDE 0281-9 : 2001 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - SINGLE CORE NON-SHEATHED CABLES FOR INSTALLATION AT LOW TEMPERATURES
    DIN EN 50265-2-1 : 1999 COMMON TEST METHODS FOR CABLES UNDER FIRE CONDITIONS - TEST FOR RESISTANCE TO VERTICAL FLAME PROPAGATION FOR A SINGLE INSULATED CONDUCTOR OR CABLE - PART 2-1: PROCEDURES - 1 KW PRE-MIXED FLAME
    DIN VDE 0281-3 : 2001 AMD 2 2009 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON SHEATHED CABLES FOR FIXED WIRING
    VDE 0281-10 : 2003 POLYVINYLCHLORID-ISOLIERTE STARKSTROMLEITUNGEN MIT NENNSPANNUNGEN BIS 450/750 V WENDELLEITUNGEN
    VDE 0281-5 : 2002 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 5: FLEXIBLE CABLES AND CORDS
    DIN VDE 0281-1 : 2003 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - PART 1: GENERAL REQUIREMENTS
    EN 50265-2-1:1998 Common test methods for cables under fire conditions - Test for resistance to vertical flame propagation for a single insulated conductor or cable - Part 2-1: Procedures - 1 kW pre-mixed flame
    VDE 0281-13 : 2003 CONDUCTEURS ET CABLES ISOLES AU POLYCHLORURE DE VINYLE, DE TENSION ASSIGNEE AU PLUS EGALE A 450/750 V - PARTIE 13: CABLES SOUPLES AVEC GAINE DE POLYCHLORURE DE VINYLE, RESISTANT A L'HUILE, A DEUX AMES OU PLUS
    VDE 0299-2 : 1994 CALCULATION OF THE LOWER AND UPPER LIMITS FOR THE AVERAGE OUTER DIMENSIONS OF CABLES WITH CIRCULAR COPPER CONDUCTORS AND OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective