• EN 1048:2014

    Current The latest, up-to-date edition.

    Heat exchangers - Air cooled liquid coolers ('dry coolers') - Test procedures for establishing the performance

    Available format(s): 

    Language(s): 

    Published date:  27-08-2014

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and Definitions
    4 Symbols
    5 Standard capacity
    6 Manufacturer's data
    7 Measurements
    8 Testing methods and equipment
    9 Test procedure
    10 Capacity calculations
    11 Conversion to standard conditions
    12 Test report
    Annex A (Normative) - Flow meter method
    Bibliography

    Abstract - (Show below) - (Hide below)

    This European Standard applies to remote forced convection air cooled liquid coolers, within which no change in the liquid phase occurs.This European Standard does not apply to liquid coolers, designed primarily for installation within the machinery compartment of packaged products.Its purpose is to establish uniform methods to test and ascertain the following:-Product identification;-Capacity;-Air flow rate;-Liquid side pressure drop;-Energy requirements.This European Standard does not cover technical safety aspects.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 110
    Development Note Supersedes ENV 1048. (10/2006) Supersedes PREN 1048. (09/2014)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Current
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 13487:2004 HEAT EXCHANGERS - FORCED CONVECTION AIR COOLED REFRIGERANT CONDENSERS AND DRY COOLERS - SOUND MEASUREMENT
    EN 13487 : 2003 HEAT EXCHANGERS - FORCED CONVECTION AIR COOLED REFRIGERANT CONDENSERS AND DRY COOLERS - SOUND MEASUREMENT
    PREN 13487 : DRAFT 2017 HEAT EXCHANGER - FORCED CONVECTION AIR COOLED REFRIGERANT CONDENSERS AND DRY COOLERS - SOUND MEASUREMENT
    17/30361327 DC : 0 BS EN 13487 - HEAT EXCHANGER - FORCED CONVECTION AIR COOLED REFRIGERANT CONDENSERS AND DRY COOLERS - SOUND MEASUREMENT
    BS EN 13487:2003 Heat exchangers. Forced convection air cooled refrigerant condensers and dry coolers. Sound measurement
    DIN EN 13487:2004-03 HEAT EXCHANGERS - FORCED CONVECTION AIR COOLED REFRIGERANT CONDENSERS AND DRY COOLERS - SOUND MEASUREMENT

    Standards Referencing This Book - (Show below) - (Hide below)

    ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
    EN 305:1997 Heat exchangers - Definitions of performance of heat exchangers and the general test procedure for establishing performance of all heat exchangers
    EN 307:1998 Heat exchangers - Guidelines to prepare installation, operating and maintenance instructions required to maintain the performance of each type of heat exchangers
    EN 306:1997 Heat exchangers - Methods of measuring the parameters necessary for establishing the performance
    EN 247:1997 Heat exchangers - Terminology
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective