• Shopping Cart
    There are no items in your cart

EN 12050-3:2015

Current

Current

The latest, up-to-date edition.

Wastewater lifting plants for buildings and sites - Part 3: Lifting plants for limited applications

Published date

18-03-2015

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Material and product characteristics
5 Testing
6 Assessment and verification of constancy
  of performance - AVCP
7 Marking, labelling and packaging
8 Manufacturer's instructions for installation,
  operation and maintenance
Annex A (informative) - Recommended materials
Annex ZA (informative) - Clauses of this European
         Standard addressing the provisions of the
         EU Construction Products Regulation
Bibliography

This European Standard applies to lifting plants for limited applications for domestic non-commercial wastewater containing or not containing faecal matter and located below flood level.NOTELimited application means that the number of users is small and the plant is located in the same room as the sanitary appliance(s) served by it ) which are installed in accordance with EN 12056–1 and the layout and calculation are in accordance with EN 12056–4.This European Standard applies to lifting plants for limited applications designed for wastewater containing faecal matter, where there is another WC available above flood level, and the plants serve no more than a single WC to which it is directly connected (at a distance of max. 0,5 m) and one hand washbasin, one shower and one bidet provided no other sanitary appliance is directly or indirectly connected.This European Standard also applies to lifting plants for limited applications designed for faecal free wastewater, where a maximum of one hand washbasin or kitchen sink plus one further appliance such as a bathtub or a washing machine or a shower or a dish washer or an urinal are connected. No other sanitary appliance shall be directly or indirectly connected.This European Standard contains general requirements, basic construction and testing principles, together with information on materials.Construction and testing requirements for non-return valves used in wastewater lifting plants for limited applications are given in EN 12050 4.This European Standard does not apply for lifting plants for limited applications for wastewater containing faecal matter where WC flushing is carried out by pressure flush valve.

Committee
CEN/TC 165
DevelopmentNote
Supersedes PREN 12050-3. (03/2015)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

PREN 12050-4 : DRAFT 2012 WASTEWATER LIFTING PLANTS FOR BUILDINGS AND SITES - PART 4: NON-RETURN VALVES FOR FAECAL-FREE WASTEWATER AND WASTEWATER CONTAINING FAECAL MATTER
EN 16932-2:2018 Drain and sewer systems outside buildings - Pumping systems - Part 2: Positive pressure systems
EN 12050-4:2015 Wastewater lifting plants for buildings and sites - Part 4: Non-return valves for faecal-free wastewater and wastewater containing faecal matter
12/30265298 DC : 0 BS EN 12050-4 - WASTEWATER LIFTING PLANTS FOR BUILDINGS AND SITES - PART 4: NON-RETURN VALVES FOR FAECAL-FREE WASTEWATER AND WASTEWATER CONTAINING FAECAL MATTER
I.S. EN 16932-2:2018 DRAIN AND SEWER SYSTEMS OUTSIDE BUILDINGS - PUMPING SYSTEMS - PART 2: GENERAL REQUIREMENTS
I.S. EN 12050-4:2015 WASTEWATER LIFTING PLANTS FOR BUILDINGS AND SITES - PART 4: NON-RETURN VALVES FOR FAECAL-FREE WASTEWATER AND WASTEWATER CONTAINING FAECAL MATTER
BS EN 16932-2:2018 Drain and sewer systems outside buildings. Pumping systems Positive pressure systems
DIN EN 12050-4:2015-05 WASTEWATER LIFTING PLANTS FOR BUILDINGS AND SITES - PART 4: NON-RETURN VALVES FOR FAECAL-FREE WASTEWATER AND WASTEWATER CONTAINING FAECAL MATTER
UNE-EN 12050-4:2015 Wastewater lifting plants for buildings and sites - Part 4: Non-return valves for faecal-free wastewater and wastewater containing faecal matter
BS EN 12050-4:2015 Wastewater lifting plants for buildings and sites Non-return valves for faecal-free wastewater and wastewater containing faecal matter
DIN EN 12056-4:2001-01 GRAVITY DRAINAGE SYSTEMS INSIDE BUILDINGS - PART 4: WASTEWATER LIFTING PLANTS - LAYOUT AND CALCULATION

ISO 9906:2012 Rotodynamic pumps — Hydraulic performance acceptance tests — Grades 1, 2 and 3
EN 12050-1:2015 Wastewater lifting plants for buildings and sites - Part 1: Lifting plants for wastewater containing faecal matter
EN 12056-2:2000 Gravity drainage systems inside buildings - Part 2: Sanitary pipework, layout and calculation
EN 12050-4:2015 Wastewater lifting plants for buildings and sites - Part 4: Non-return valves for faecal-free wastewater and wastewater containing faecal matter
EN 12056-4:2000 Gravity drainage systems inside buildings - Part 4: Wastewater lifting plants - Layout and calculation
EN 12056-1:2000 Gravity drainage systems inside buildings - Part 1: General and performance requirements
EN 13823:2010+A1:2014 Reaction to fire tests for building products - Building products excluding floorings exposed to the thermal attack by a single burning item
EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
ISO 9001:2015 Quality management systems — Requirements
EN 1563:2011 Founding - Spheroidal graphite cast irons
EN ISO 9906:2012 Rotodynamic pumps - Hydraulic performance acceptance tests - Grades 1, 2 and 3 (ISO 9906:2012)
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
ISO 20361:2015 Liquid pumps and pump units Noise test code Grades 2 and 3 of accuracy
EN 1561:2011 Founding - Grey cast irons
EN 10088-1:2014 Stainless steels - Part 1: List of stainless steels

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.