Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances
17-12-2014
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Calculation methods for reference
SGUE and SAEF in cooling mode
5 Calculation methods for reference seasonal
performance in heating mode
Annex A (informative) - Calculation example
for reference SGUEc and SAEFc
Annex B (informative) - Calculation example for
reference SGUEh, SAEFh and SPERh
Annex C (normative) - Number of hours in thermostat
off mode, stand-by mode and off mode for
reference SAEFc and SAEFh calculation
Annex D (normative) - Calculation of the reference
seasonal performance in heating mode for
bivalent appliances
Annex E (normative) - Procedures for the determination
of GUEh, AEFh and SAEFh value with multiple
identical heat pumps
Annex F (informative) - Table of tables for part load
conditions in heating mode
Annex G (normative) - Calculation of seasonal space
heating energy efficiency for monovalent or
bivalent gas-driven sorption heat pump based
heating appliances
Annex ZA (informative) - Relationship between this
European Standard and the requirements of
Commission Regulation (EC) No 813/2013
Annex ZB (informative) - Relationship between this
European Standard and the requirements of
Commission Regulation (EC) No 811/2013
Bibliography
1.1Scope of EN 12309 Appliances covered by this standard include one or a combination of the following:-gas-fired sorption chiller;-gas-fired sorption chiller/heater;-gas-fired sorption heat pump.This European Standard applies to appliances designed to be used for space heating or cooling or refrigeration with or without heat recovery.This European Standard applies to appliances having flue gas systems of type B and type C (according to CEN/TR 1749) and to appliances designed for outdoor installations. EN 12309 does not apply to air conditioners, it only applies to appliances having:-integral burners under the control of fully automatic burner control systems,-closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated,-mechanical means to assist transportation of the combustion air and/or the flue gas.The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in EN 12309 1:2014).In the case of packaged units (consisting of several parts), this European Standard applies only to those designed and supplied as a complete package.The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by EN 12309.Installations used for heating and/or cooling of industrial processes are not within the scope of EN 12309.All the symbols given in this text should be used regardless of the language used.1.2Scope of this Part 6 to EN 12309This part of EN 12309 specifies the calculation methods of seasonal performances for gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW. It deals in particular with the calculation methods of reference seasonal performances in cooling and heating mode for monovalent and bivalent appliances.NOTEThis European Standard serves as an input for the calculation of the system energy efficiency in heating mode of specific heat pump systems in buildings, as stipulated in EN 15316-4-2.
Committee |
CEN/TC 299
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Supersedes |
Standards | Relationship |
I.S. EN 12309-6:2014 | Identical |
NF EN 12309-6 : 2015 | Identical |
SN EN 12309-6 : 2015 | Identical |
DIN EN 12309-6:2015-03 | Identical |
BS EN 12309-6:2014 | Identical |
UNE-EN 12309-6:2015 | Identical |
NS EN 12309-6 : 2014 | Identical |
PN EN 12309-6 : 2015 | Identical |
UNI EN 12309-6 : 1ED 2015 | Identical |
NEN EN 12309-6 : 2015 | Identical |
NBN EN 12309-6 : 2015 | Identical |
DIN EN 12309-7:2015-03 | Identical |
I.S. EN 12309-3:2014 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 3: TEST CONDITIONS |
BS EN 12309-7:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Specific provisions for hybrid appliances |
BS EN 15316-4-2:2017 | Energy performance of buildings. Method for calculation of system energy requirements and system efficiencies Space heating generation systems, heat pump systems, Module M3-8-2, M8-8-2 |
UNE-EN 16905-1:2017 | Gas-fired endothermic engine driven heat pumps - Part 1: Terms and definitions |
EN 12309-7:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 7: Specific provisions for hybrid appliances |
EN 12309-1:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions |
EN 12309-3:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 3: Test conditions |
DIN EN 12309-7:2015-03 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 7: SPECIFIC PROVISIONS FOR HYBRID APPLIANCES |
15/30326263 DC : 0 | BS EN 16905-1 - GAS-FIRED ENDOTHERMIC ENGINE HEAT PUMPS - PART 1: TERMS AND DEFINITIONS |
I.S. EN 16905-3:2017 | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 3: TEST CONDITIONS |
I.S. EN 12309-1:2014 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 1: TERMS AND DEFINITIONS |
DIN EN 12309-3:2015-03 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 3: TEST CONDITIONS |
BS EN 12309-3:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Test conditions |
15/30326257 DC : 0 | BS EN 16905-3 - GAS-FIRED ENDOTHERMIC ENGINE HEAT PUMPS - PART 3: TEST CONDITIONS |
DIN EN 12309-5:2015-03 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 5: REQUIREMENTS |
UNE-EN 12309-4:2015 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods |
DIN EN 12309-1:2015-03 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions |
DIN EN 16905-1:2015-10 (Draft) | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 1: TERMS AND DEFINITIONS |
BS EN 12309-4:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Test methods |
BS EN 16905-3:2017 | Gas-fired endothermic engine driven heat pumps Test conditions |
BS EN 12309-5:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Requirements |
I.S. EN 12309-7:2014 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 7: SPECIFIC PROVISIONS FOR HYBRID APPLIANCES |
I.S. EN 12309-5:2014 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 5: REQUIREMENTS |
I.S. EN 12309-4:2014 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 4: TEST METHODS |
EN 12309-4:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods |
EN 16905-1:2017 | Gas-fired endothermic engine driven heat pumps - Part 1: Terms and definitions |
EN 16905-3:2017 | Gas-fired endothermic engine driven heat pumps - Part 3: Test conditions |
DIN EN 16905-3:2015-10 (Draft) | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 3: TEST CONDITIONS |
DIN EN 15316-4-2:2008-09 | ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-2: SPACE HEATING GENERATION SYSTEMS, HEAT PUMP SYSTEMS, MODULE M3-8-2, M8-8-2 |
BS EN 16905-1:2017 | Gas-fired endothermic engine driven heat pumps Terms and definitions |
I.S. EN 16905-1:2017 | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 1: TERMS AND DEFINITIONS |
UNE-EN 16905-3:2017 | Gas-fired endothermic engine driven heat pumps - Part 3: Test conditions |
I.S. EN 15316-4-2:2017 | ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-2: SPACE HEATING GENERATION SYSTEMS, HEAT PUMP SYSTEMS, MODULE M3-8-2, M8-8-2 |
BS EN 12309-1:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Terms and definitions |
I.S. EN 15316-4-2:2017+AC:2017 | ENERGY PERFORMANCE OF BUILDINGS - METHOD FOR CALCULATION OF SYSTEM ENERGY REQUIREMENTS AND SYSTEM EFFICIENCIES - PART 4-2: SPACE HEATING GENERATION SYSTEMS, HEAT PUMP SYSTEMS, MODULE M3-8-2, M8-8-2 |
EN 12309-5:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 5: Requirements |
DIN EN 16905-3:2017-09 | GAS-FIRED ENDOTHERMIC ENGINE DRIVEN HEAT PUMPS - PART 3: TEST CONDITIONS |
EN 15502-1:2012+A1:2015 | Gas-fired heating boilers - Part 1: General requirements and tests |
EN 12309-1:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions |
EN 12309-4:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods |
EN 12309-5:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 5: Requirements |
CEN/TR 1749:2014 | European scheme for the classification of gas appliances according to the method of evacuation of the combustion products (types) |
EN 12309-3:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 3: Test conditions |
EN 12309-7:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 7: Specific provisions for hybrid appliances |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.