EN 12309-7:2014
Current
The latest, up-to-date edition.
Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 7: Specific provisions for hybrid appliances
17-12-2014
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Test conditions
5 Calculation of the seasonal
performance in the heating mode
6 Standard rating conditions of gas driven
sorption heat pump based hybrid heating
appliances
Annex A (informative) - Estimation of the
heating fluid inlet and outlet temperature
into/out of the indoor heat exchanger
Annex B (informative) - Inlet temperature
into the outdoor heat exchanger for
ground heat sourced sorption heat pump
based hybrid heating appliances
Annex C (informative) - Inlet temperature into
the outdoor heat exchanger for solar sourced
sorption heat pump based hybrid heating
appliances
Annex D (informative) - Inlet temperature of
the outdoor heat exchanger for solar
collector assisted sorption heat pump
based hybrid heating appliances
Annex E (informative) - Calculation of the seasonal
gas utilization efficiency with partial heat
demand coverage by the applied solar collectors
Annex F (informative) - Estimation of the seasonal
performance of hybrid heating appliances at
building design loads deviating from the
appliance's nominal heating capacity
Annex G (normative) - Calculation of the seasonal
space heating energy efficiency for hybrid
gas-driven sorption heat pump based heating
appliances
Annex ZA (informative) - Relationship between
this European Standard and the requirements
of Commission Regulation (EC) No 813/2013
Annex ZB (informative) - Relationship between this
European Standard and the requirements of
Commission Regulation (EC) No 811/2013
Bibliography
1.1Scope of EN 12309 Appliances covered by this European Standard include one or a combination of the following:-gas-fired sorption chiller;-gas-fired sorption chiller/heater;-gas-fired sorption heat pump.This European Standard applies to appliances designed to be used for space heating or cooling or refrigeration with or without heat recovery.This European Standard applies to appliances having flue gas systems of type B and C (according to CEN/TR 1749) and to appliances designed for outdoor installations. EN 12309 does not apply to air conditioners, it only applies to appliances having:-integral burners under the control of fully automatic burner control systems,-closed system refrigerant circuits in which the refrigerant does not come into direct contact with the water or air to be cooled or heated,-mechanical means to assist transportation of the combustion air and/or the flue gas.The above appliances can have one or more primary or secondary functions (i.e. heat recovery - see definitions in prEN 12309 1:2012).In the case of packaged units (consisting of several parts), this standard applies only to those designed and supplied as a complete package.The appliances having their condenser cooled by air and by the evaporation of external additional water are not covered by EN 12309.Installations used for heating and/or cooling of industrial processes are not within the scope of EN 12309.All the symbols given in this text should be used regardless of the language used.1.2Scope of this Part 7 of EN 12309This part of EN 12309 deals particularly with the specific provisions of hybrid heating appliances based on gas-driven sorption heat pumps as defined in Part 1.The heating appliances covered by this European Standard are of a hybrid type, an encased assembly or assemblies combining a direct or indirect-fired sorption heat pump for base load and a peak load condensing boiler with only one flue system, electrical supply cable and human machine interface to the end user. The direct- or indirect-fired sorption heat pump integrated in the hybrid appliances in this European Standard could be intermittent or continuously operating ab or adsorption heat pump.The control system of hybrid heating appliances decides on the transition between the heat pump operation mode to/from the mixed operation mode (heating by both sorption heat pump as well as the peak boiler) and the direct heating mode (only peak boiler) depending on the heating fluid inlet or return temperature, temperature of brine entering the indoor heat exchanger (evaporator) of the heat pump, the required outlet or supply temperature dependent on the outdoor temperature as well as the target value of the indoor or room temperature. Upon transition from the heat pump operation mode to the mixed operation mode, the control system decides also on the degree of mixing based on the above mentioned parameters.
Committee |
CEN/TC 299
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NF EN 12309-7 : 2015 | Identical |
SN EN 12309-7:2015 | Identical |
NEN EN 12309-7 : 2015 | Identical |
UNI EN 12309-7 : 2015 | Identical |
I.S. EN 12309-7:2014 | Identical |
NBN EN 12309-7 : 2015 | Identical |
UNE-EN 12309-7:2015 | Identical |
NS EN 12309-7 : 2014 | Identical |
BS EN 12309-7:2014 | Identical |
PN EN 12309-7 : 2015 | Identical |
I.S. EN 12309-3:2014 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 3: TEST CONDITIONS |
I.S. EN 12309-6:2014 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 6: CALCULATION OF SEASONAL PERFORMANCES |
EN 12309-6:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances |
EN 12309-1:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions |
EN 12309-3:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 3: Test conditions |
I.S. EN 12309-1:2014 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 1: TERMS AND DEFINITIONS |
DIN EN 12309-3:2015-03 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 3: TEST CONDITIONS |
BS EN 12309-3:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Test conditions |
BS EN 12309-6:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Calculation of seasonal performances |
DIN EN 12309-5:2015-03 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 5: REQUIREMENTS |
UNE-EN 12309-4:2015 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods |
UNE-EN 12309-6:2015 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances |
DIN EN 12309-1:2015-03 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions |
BS EN 12309-4:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Test methods |
BS EN 12309-5:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Requirements |
I.S. EN 12309-5:2014 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 5: REQUIREMENTS |
I.S. EN 12309-4:2014 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 4: TEST METHODS |
EN 12309-4:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods |
DIN EN 12309-6:2015-03 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances |
BS EN 12309-1:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW Terms and definitions |
EN 12309-5:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 5: Requirements |
EN 12309-1:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 1: Terms and definitions |
EN 12309-6:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 6: Calculation of seasonal performances |
EN 12309-4:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 4: Test methods |
VDI 4650 Blatt 2:2013-01 | Simplified method for the calculation of the annual heating energy ratio and the annual gas utilisation efficiency of sorption heat pumps - Gas heat pumps for space heating and domestic hot water |
VDI 4640 Blatt 2:2001-09 | Thermal use of the underground - Ground source heat pump systems |
EN 12309-5:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 5: Requirements |
CEN/TR 1749:2014 | European scheme for the classification of gas appliances according to the method of evacuation of the combustion products (types) |
EN 12309-3:2014 | Gas-fired sorption appliances for heating and/or cooling with a net heat input not exceeding 70 kW - Part 3: Test conditions |
EN 442-2:2014 | Radiators and convectors - Part 2: Test methods and rating |
PREN 12309-2 : DRAFT 2013 | GAS-FIRED SORPTION APPLIANCES FOR HEATING AND/OR COOLING WITH A NET HEAT INPUT NOT EXCEEDING 70 KW - PART 2: SAFETY |
Access your standards online with a subscription