EN 12613:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Plastics warning devices for underground cables and pipelines with visual characteristics
01-02-2021
24-06-2009
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Material
5 Requirements
5.1 Colour
5.2 Appearance and colour fastness
5.3 Dimensional characteristics
5.4 Laying characteristics
5.4.1 General
5.4.2 Tensile withstand strength
5.4.3 Transversal rigidity
5.4.4 Flatness
5.5 Visual warning characteristics
5.6 Resistance against micro-organisms
5.7 Resistance to UV-light
5.8 Temperature stability
5.9 Resistance of printing
5.10 Marking
6 Test methods
6.1 Test pieces and test conditions
6.2 Colour fastness
6.3 Tensile withstand strength
6.3.1 Test pieces
6.3.2 Apparatus
6.3.3 Procedure
6.4 Transversal rigidity
6.5 Flatness
7 Factory production control tests
8 Test report
Annex A (normative) - Determination of visual warning
characteristics by simulation of
trench opening
A.1 Principle
A.2 Apparatus
A.3 Test pieces
A.4 Conditioning and test temperature
A.5 Procedure
A.6 Test conditions for warning devices wider than
500 mm
Annex B (normative) - Chemical resistance to ammonium
sulphide
B.1 Apparatus
B.2 Preparation of test pieces
B.3 Procedure
This European Standard specifies the material, mechanical and functional (fitness for purpose) requirementsfor warning devices with visual characteristics manufactured from plastics, intended to indicate the presenceof cables and piping systems buried in ground when opening trenches and more generally during diggingwork.This European Standard also specifies the test methods referred to in this document.This European Standard is applicable to two types of visual warning devices: tapes (type 1) and meshes(type 2).
Committee |
CEN/TC 249
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
ONORM EN 12613 : 2009 | Identical |
UNI EN 12613 : 2009 | Identical |
I.S. EN 12613:2009 | Identical |
SN EN 12613 : 2010 | Identical |
NS EN 12613 : 2009 | Identical |
BS EN 12613:2009 | Identical |
UNE-EN 12613:2010 | Identical |
NEN EN 12613 : 2009 | Identical |
NF EN 12613 : 2009 | Identical |
DIN EN 12613:2009-09 | Identical |
PN EN 12613 : 2010 | Identical |
NBN EN 12613 : 2009 | Identical |
I.S. EN 50520:2009 | COVER PLATES AND COVER TAPES FOR THE PROTECTION AND LOCATION WARNING OF BURIED CABLES OR BURIED CONDUITS IN UNDERGROUND INSTALLATIONS |
BS EN 50174-3 : 2013 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
BS EN 50520:2009 | Cover plates and cover tapes for the protection and location warning of buried cables or buried conduits in underground installations |
CEI EN 50520 : 2010 | COVER PLATES AND COVER TAPES FOR THE PROTECTION AND LOCATION WARNING OF BURIED CABLES OR BURIED CONDUITS IN UNDERGROUND INSTALLATIONS |
CEI EN 50174-3 : 2014 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
PREN 50520 : DRAFT 2015 | COVER PLATES AND COVER TAPES FOR THE PROTECTION AND LOCATION WARNING OF BURIED CABLES OR BURIED CONDUITS IN UNDERGROUND INSTALLATIONS |
12/30260552 DC : 0 | BS EN 50174-3:201X - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
08/30178072 DC : DRAFT FEB 2008 | BS EN 50520 - COVER PLATES AND FOILS FOR THE PROTECTION AND WARNING OF THE LOCATION OF CABLES OR BURIED CONDUITS IN UNDERGROUND INSTALLATIONS |
I.S. EN 50174-3:2013 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
PREN 50174-3 : DRAFT 2012 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
EN 50520:2009 | Cover plates and cover tapes for the protection and location warning of buried cables or buried conduits in underground installations |
15/30331067 DC : 0 | BS EN 50520 - COVER PLATES AND COVER TAPES FOR THE PROTECTION AND LOCATION WARNING OF BURIED CABLES OR BURIED CONDUITS IN UNDERGROUND INSTALLATIONS |
EN 50174-3:2013/A1:2017 | INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
02/637047 DC : DRAFT APR 2002 | BS EN 50174-3 - INFORMATION TECHNOLOGY - CABLING INSTALLATION - PART 3: INSTALLATION PLANNING AND PRACTICES OUTSIDE BUILDINGS |
ISO 4892-1:2016 | Plastics — Methods of exposure to laboratory light sources — Part 1: General guidance |
EN ISO 4892-1:2016 | Plastics - Methods of exposure to laboratory light sources - Part 1: General guidance (ISO 4892-1:2016) |
ISO 846:1997 | Plastics Evaluation of the action of microorganisms |
ISO 175:2010 | Plastics Methods of test for the determination of the effects of immersion in liquid chemicals |
EN ISO 846:1997 | Plastics - Evaluation of the action of microorganisms (ISO 846:1997) |
EN 60898-1:2003/A13:2012 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED) |
IEC 60898-1:2015 | Electrical accessories - Circuit-breakers for overcurrent protection for household and similar installations - Part 1: Circuit-breakers for a.c. operation |
EN 60898-1:2003/A13:2012 | ELECTRICAL ACCESSORIES - CIRCUIT BREAKERS FOR OVERCURRENT PROTECTION FOR HOUSEHOLD AND SIMILAR INSTALLATIONS - PART 1: CIRCUIT-BREAKERS FOR A.C. OPERATION (IEC 60898-1:2002, MODIFIED) |
EN ISO 175:2010 | Plastics - Methods of test for the determination of the effects of immersion in liquid chemicals (ISO 175:2010) |