• EN 1279-2:2002

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Glass in building - Insulating glass units - Part 2: Long term test method and requirements for moisture penetration

    Available format(s): 

    Superseded date:  28-02-2019

    Language(s): 

    Published date:  13-11-2002

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions, abbreviations and symbols
      3.1 Terms and definitions
      3.2 Abbreviations
      3.3 Symbols
    4 Requirements
      4.1 Moisture penetration index
      4.2 Edge seal strength
      4.3 Gas leakage rate
    5 Method of test
      5.1 Principle
      5.2 Climate conditions in cabinet
      5.3 Number, description and selection of the test
          specimens
      5.4 Procedure
    6 Methods of measurement
      6.1 Measurement of dew point temperature
      6.2 Measurement of moisture content
          6.2.1 General
          6.2.2 Moisture content of desiccant in bulk
          6.2.3 Moisture content of desiccant incorporated
                in organic spacer
          6.2.4 Moisture content in insulating glass units
                without desiccant
    7 Test report
    Annex A (normative) - Reference method for dew point
            temperature measurement
        A.1 General
        A.2 Apparatus and materials
        A.3 Procedure
    Annex B (normative) - Moisture content measurement
            according to the 950 degree C drying method
        B.1 Applicability
        B.2 Apparatus, materials and preparatory work
        B.3 Initial and final moisture content
        B.4 Standard moisture adsorption capacity
    Annex C (normative) - Moisture content measurement
            according to the Karl Fischer method
        C.1 Applicability
        C.2 Apparatus, materials and preparatory work
        C.3 Initial and final moisture content
        C.4 Standard moisture adsorption capacity
    Annex D (normative) - Establishing the standard moisture
            adsorption capacity of desiccants
        D.1 General
        D.2 Appropriate information
        D.3 Generally accepted values for desiccant in bulk
        D.4 Desiccant manufacturing
    Bibliography

    Abstract - (Show below) - (Hide below)

    This draft European Standard is the product standard fo insulating glass units, which defines insulating glass units, and ensures by means of an adequate evaluation of conformity to this standard that: - energy savings are made because the U-value and solar factor do not change significantly; - health because sound reduction and vision do not change significantly; - safety is provided because mechanical resistance does not change significantly.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 129
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    PREN 13830 : DRAFT 2013 CURTAIN WALLING - PRODUCT STANDARD
    BS EN 1279-1:2004 Glass in building. Insulating glass units Generalities, dimensional tolerances and rules for the system description
    UNI EN 1279-5 : 2010 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY
    BS EN 357:2004 Glass in building. Fire resistant glazed elements with transparent or translucent glass products. Classification of fire resistance
    EN 1096-3:2012 Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings
    DIN EN 13830:2015-07 CURTAIN WALLING - PRODUCT STANDARD
    BS EN 50583-1:2016 Photovoltaics in buildings BIPV modules
    13/30281348 DC : 0 BS EN 13830 - CURTAIN WALLING - PRODUCT STANDARD
    I.S. EN 1279-1:2004 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION
    I.S. EN 1279-3:2002 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 3: LONG TERM TEST METHOD AND REQUIREMENTS FOR GAS LEAKAGE RATE AND FOR GAS CONCENTRATION TOLERANCES
    DIN EN 1279-5:2015-08 (Draft) GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY
    I.S. EN 13830:2015 CURTAIN WALLING - PRODUCT STANDARD
    I.S. EN 1096-3:2012 GLASS IN BUILDING - COATED GLASS - PART 3: REQUIREMENTS AND TEST METHODS FOR CLASS C AND D COATINGS
    I.S. EN 357:2004 GLASS IN BUILDING - FIRE RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE
    EN 1279-5:2005+A2:2010 Glass in building - Insulating glass units - Part 5: Evaluation of conformity
    12/30266506 DC : 0 BS EN 50583 - PHOTOVOLTAICS IN BUILDINGS
    NF EN 1279-5 : 2005 + A2 2010 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY
    EN 1279-3:2002 Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances
    I.S. EN 1279-5:2005 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY
    DIN EN 1096-3:2012-04 Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings
    UNE-EN 13830:2016 Curtain walling - Product standard
    UNE-EN 1096-3:2012 Glass in building - Coated glass - Part 3: Requirements and test methods for class C and D coatings
    EN 13830:2015 Curtain walling - Product standard
    UNI EN 1096-3 : 2012 GLASS IN BUILDING - COATED GLASS - PART 3: REQUIREMENTS AND TEST METHODS FOR CLASS C AND D COATINGS
    03/100996 DC : DRAFT MAR 2003 PREN 13022-1 - GLASS IN BUILDING - STRUCTURAL SEALANT GLAZING - GLASS PRODUCTS FOR STRUCTURAL SEALANT GLAZING SYSTEMS - SUPPORTED AND UNSUPPORTED MONOLITHIC AND MULTIPLE GLAZING
    PREN 50583 : DRAFT 2012 PHOTOVOLTAICS IN BUILDINGS
    I.S. EN 50583-1:2016 PHOTOVOLTAICS IN BUILDINGS - PART 1: BIPV MODULES
    BS EN 13830:2015 Curtain walling. Product standard
    EN 357:2004 Glass in building - Fire resistant glazed elements with transparent or translucent glass products - Classification of fire resistance
    UNE-EN 50583-1:2016 Photovoltaics in buildings - Part 1: BIPV modules
    EN 1279-1:2004/AC:2006 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION
    BS EN 1279-3:2002 Glass in building. Insulating glass units Long term test method and requirements for gas leakage rate and for gas concentration tolerances
    08/30172148 DC : DRAFT MAY 2008 BS ISO 28278-1 - GLASS IN BUILDING - GLASS PRODUCTS FOR STRUCTURAL SEALANT GLAZING - PART 1: SUPPORTED AND UNSUPPORTED MONOLITHIC AND MULTIPLE GLAZING
    BS EN 1279-5 : 2005 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 5: EVALUATION OF CONFORMITY
    DIN EN 1279-1:2015-08 (Draft) GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES, DIMENSIONAL TOLERANCES AND RULES FOR THE SYSTEM DESCRIPTION
    BS EN 1096-3:2012 Glass in building. Coated glass Requirements and test methods for class C and D coatings
    EN 50583-1:2016 Photovoltaics in buildings - Part 1: BIPV modules
    DIN EN 1279-3:2003-05 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 3: LONG TERM TEST METHOD AND REQUIREMENTS FOR GAS LEAKAGE RATE AND FOR GAS CONCENTRATION TOLERANCES
    DIN EN 357:2005-02 GLASS IN BUILDING - FIRE-RESISTANT GLAZED ELEMENTS WITH TRANSPARENT OR TRANSLUCENT GLASS PRODUCTS - CLASSIFICATION OF FIRE RESISTANCE
    UNE-EN 1279-5:2006 Glass in building - Insulating glass units - Part 5: Evaluation of conformity

    Standards Referencing This Book - (Show below) - (Hide below)

    PREN 1279-1 : DRAFT 95 GLASS IN BUILDING - INSULATING GLASS UNITS - PART 1: GENERALITIES AND DIMENSIONAL TOLERANCES
    EN 1279-6:2002 Glass in building - Insulating glass units - Part 6: Factory production control and periodic tests
    EN 572-2:2012 Glass in building - Basic soda lime silicate glass products - Part 2: Float glass
    EN 1279-3:2002 Glass in building - Insulating glass units - Part 3: Long term test method and requirements for gas leakage rate and for gas concentration tolerances
    EN 1279-4:2002 Glass in building - Insulating glass units - Part 4: Methods of test for the physical attributes of edge seals
    EN ISO 9001:2015 Quality management systems - Requirements (ISO 9001:2015)
    ISO 9001:2015 Quality management systems — Requirements
    EN 572-1:2012+A1:2016 Glass in building - Basic soda-lime silicate glass products - Part 1: Definitions and general physical and mechanical properties
    ISO 760:1978 Determination of water Karl Fischer method (General method)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective