EN 13124-2:2004
Current
The latest, up-to-date edition.
Windows, doors and shutters - Explosion resistance - Test method - Part 2: Range test
25-02-2004
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Requirements
5 Apparatus
6 Test specimen
7 Procedure
8 Sequence of test
9 Evaluation of results
10 Test report
11 Test report summary
Annex A (normative) TNT explosive charge
Annex B (normative) Idealised pressure-time variation
for a blast wave and orientation of test specimen
and explosive charge
Tables
Figures
This European Standard specifies a test procedure to permit classification of the explosion resistance of windows, doors and shutters together with their infills.This European Standard concerns a test method against blast waves in open air resulting from high explosives that can be carried by hand and placed a few metres from a target. At such close distances blast values vary across an attack face. Controlled measurement of the actual blast on the face of the test specimen being difficult, costly and subject to inaccuracy, consistency of the blast forces is therefore controlled in this European Standard by the characteristics of the explosive charge and its location (see annex A and annex B).This European Standard covers only the behaviour of the complete unit including infill, frame and fixings as tested. It gives no information on the ability of the surrounding wall or building structure to resist the direct or transmitted forces.If the windows, doors and shutters are intended for specific conditions of climate, specific test conditions can be required.This European Standard gives no information on the behaviour of the units subjected to other types of loading.
Committee |
CEN/TC 33
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
SN EN 13124-2 : 2004 | Identical |
DIN EN 13124-2:2004-05 | Identical |
I.S. EN 13124-2:2004 | Identical |
PN EN 13124-2 : 2004 | Identical |
BS EN 13124-2:2004 | Identical |
UNI EN 13124-2 : 2005 | Identical |
NS EN 13124-2 : 1ED 2004 | Identical |
UNE-EN 13124-2:2004 | Identical |
NBN EN 13124-2 : 2004 | Identical |
NF EN 13124-2 : 2004 | Identical |
NEN EN 13124-2 : 2004 | Identical |
14/30302455 DC : 0 | BS EN 13659 - SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
ISO 16933:2007 | Glass in building — Explosion-resistant security glazing — Test and classification for arena air-blast loading |
11/30245760 DC : 0 | BS EN 13541 - GLASS IN BUILDING - SECURITY GLAZING - TESTING AND CLASSIFICATION OF RESISTANCE AGAINST EXPLOSION PRESSURE |
PREN 13541 : DRAFT 2011 | GLASS IN BUILDING - SECURITY GLAZING - TESTING AND CLASSIFICATION OF RESISTANCE AGAINST EXPLOSION PRESSURE |
EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
17/30341100 DC : 0 | BS ISO 18758-2 - MINING AND EARTH-MOVING MACHINERY - ROCK DRILL RIGS AND ROCK REINFORCEMENT RIGS - PART 2: SAFETY REQUIREMENTS |
PREN 14351-2 : DRAFT 2014 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
PREN 13659 : DRAFT 2014 | SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
I.S. EN 14351-1:2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND/OR SMOKE LEAKAGE CHARACTERISTICS |
I.S. EN 13659:2015 | SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
I.S. EN 13541:2012 | GLASS IN BUILDING - SECURITY GLAZING - TESTING AND CLASSIFICATION OF RESISTANCE AGAINST EXPLOSION PRESSURE |
DIN EN 13123-2:2004-05 | Windows, doors, and shutters - Explosion resistance - Requirements and classification - Part 2: Range test; German version EN 13123-2:2004 |
ISO 16934:2007 | Glass in building — Explosion-resistant security glazing — Test and classification by shock-tube loading |
BS EN 13123-2:2004 | Windows, doors, and shutters. Explosion resistance. Requirements and classification Range test |
EN 13123-2:2004 | Windows, doors, and shutters - Explosion resistance - Requirements and classification - Part 2: Range test |
UNI EN 13541 : 2012 | GLASS IN BUILDING - SECURITY GLAZING - TESTING AND CLASSIFICATION OF RESISTANCE AGAINST EXPLOSION PRESSURE |
11/30241851 DC : 0 | BS EN 13659 - SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
UNE-EN 13659:2016 | Shutters and external venetian blinds - Performance requirements including safety |
UNE-EN 13541:2012 | Glass in building - Security glazing - Testing and classification of resistance against explosion pressure |
BS EN 14351-1 : 2006 | WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 1: WINDOWS AND EXTERNAL PEDESTRIAN DOORSETS |
BS EN 13541:2012 | Glass in building. Security glazing. Testing and classification of resistance against explosion pressure |
EN 14351-1:2006+A2:2016 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets |
EN 13659:2015 | Shutters and external venetian blinds - Performance requirements including safety |
04/30123909 DC : DRAFT OCT 2004 | ISO 16934 - GLASS IN BUILDING - EXPLOSION-RESISTANT SECURITY GLAZING - TEST AND CLASSIFICATION BY SHOCK TUBE LOADING |
04/30124225 DC : DRAFT OCT 2004 | ISO/DIS 16933 - GLASS IN BUILDING - EXPLOSION-RESISTANT SECURITY GLAZING - TEST AND CLASSIFICATION BY ARENA AIR-BLAST LOADING |
14/30297827 DC : 0 | BS EN 14351-2 - WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS |
ISO 18758-2:2018 | Mining and earth-moving machinery — Rock drill rigs and rock reinforcement rigs — Part 2: Safety requirements |
DIN EN 13541:2012-06 | GLASS IN BUILDING - SECURITY GLAZING - TESTING AND CLASSIFICATION OF RESISTANCE AGAINST EXPLOSION PRESSURE |
DIN EN 13659:2015-07 | SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY |
BS EN 13659:2015 | Shutters and external venetian blinds. Performance requirements including safety |
UNE-EN 14351-1:2006 | Windows and doors - Product standard, performance characteristics - Part 1: Windows and external pedestrian doorsets without resistance to fire and/or smoke leakage characteristics |
EN 13123-2:2004 | Windows, doors, and shutters - Explosion resistance - Requirements and classification - Part 2: Range test |