• Shopping Cart
    There are no items in your cart

EN 13384-2:2015

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Chimneys - Thermal and fluid dynamic calculation methods - Part 2: Chimneys serving more than one heating appliance

Published date

01-04-2015

Superseded date

21-06-2019

Superseded by

EN 13384-2:2015+A1:2019

Sorry this product is not available in your region.
Summarise this standard

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General symbols and abbreviations
5 Calculation method
6 Flue gas data characterising the heating appliance
7 Data for chimney and connecting flue pipes
8 Basic data for the calculation
9 Determination of temperatures
10 Mixing calculations
11 Density and velocity of the flue gas
12 Determination of the pressures
13 Inner wall temperature
14 Cascade installations
15 Balanced flue chimney
16 Consideration of chimney fans
Annex A (informative) - Recommendations
Annex B (informative) - Characteristics for the
        heating appliance

This part of EN 13384 specifies methods for calculation of the thermal and fluid dynamic characteristics of chimneys serving more than one heating appliance.This part of EN 13384 covers both the cases, eithera)where the chimney is connected with more than one connecting flue pipe from individual or several appliances in a multi-inlet arrangement; orb)where the chimney is connected with an individual connecting flue pipe connecting more than one appliance in a cascade arrangement.The case of multiple inlet cascade arrangement is covered by the case a).This part of EN 13384 deals with chimneys operating under negative pressure conditions (there can be positive pressure condition in the connecting flue pipe) and with chimneys operating under positive pressure conditions and is valid for chimneys serving heating appliances for liquid, gaseous and solid fuels.This part of EN 13384 does not apply to:-chimneys with different thermal resistance or different cross-section in the various chimney segments. This part does not apply to calculate energy gain;-chimneys with open fire places, e.g. open fire chimneys or chimney inlets which are normally intended to operate open to the room;-chimneys which serve different kinds of heating appliances regarding natural draught, fan assisted, forced draught or combustion engine. Fan assisted appliances with draught diverter between the fan and the chimney are considered as natural draught appliances;-chimneys with multiple inlets from more than 5 storeys. (This does not apply to balanced flue chimney.);-chimneys serving heating appliances with open air supply through ventilation openings or air ducts, which are not installed in the same air supply pressure region (e.g. same side of building).For positive pressure chimneys this part only applies if any heating appliance which is out of action can be positively isolated to prevent flue gas back flow.

Committee
CEN/TC 166
DevelopmentNote
Supersedes PREN 13384-2. (04/2015)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy
Supersedes

Sorry this product is not available in your region.