• EN 13565-2:2009/AC:2010

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    FIXED FIREFIGHTING SYSTEMS - FOAM SYSTEMS - PART 2: DESIGN, CONSTRUCTION AND MAINTENANCE

    Available format(s): 

    Superseded date:  22-02-2022

    Language(s): 

    Published date:  12-01-2013

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Foam extinguishing systems
       4.1 General
            4.1.1 General requirements
            4.1.2 Environmental considerations
            4.1.3 Planning
            4.1.4 Documentation
            4.1.5 Supplementary manual foam fire fighting
                   provisions
            4.1.6 Equipment
       4.2 Water supply
            4.2.1 Water demand
            4.2.2 Operating time
            4.2.3 Quality of water
            4.2.4 Power supply for water pumps
       4.3 Foam concentrate
            4.3.1 General
            4.3.2 Foam concentrate supply - low and medium
                   expansion foams
            4.3.3 Foam concentrate pumps
            4.3.4 Supplementary external connections
       4.4 Foam proportioners
       4.5 Pipework
            4.5.1 Water and foam solution pipework
            4.5.2 Foam concentrate piping
            4.5.3 Non Newtonian foam concentrate
            4.5.4 Piping of aspirated foam (including that for
                   subsurface foam applications)
            4.5.5 Marking
       4.6 Foam discharge outlets and generators
       4.7 Operation and control systems
            4.7.1 Detection of fires
            4.7.2 Release of fixed foam extinguishing systems
            4.7.3 Alarms
    5 Design
       5.1 Application rates
       5.2 Flammable liquid storage tanks, bunds and process
            areas
            5.2.1 General
            5.2.2 Number of foam discharge outlets
            5.2.3 Fixed cone roof tanks
            5.2.4 Floating roof tanks
            5.2.5 Bunded/diked areas and process areas
    6 Foam sprinkler and deluge systems
       6.1 Deluge systems
            6.1.1 Deluge applications
            6.1.2 Deluge limitations
            6.1.3 Deluge design
       6.2 Foam enhanced sprinkler systems
            6.2.1 Foam enhanced sprinkler applications
            6.2.2 Foam enhanced sprinkler limitations
            6.2.3 Foam enhanced sprinkler design
       6.3 Foam concentrate
            6.3.1 Aspirated foams
            6.3.2 Non aspirated foams
       6.4 Foam proportioning
       6.5 Drain and flushing connections
    7 High expansion foam systems
       7.1 General
       7.2 Foam concentrate
       7.3 Equipment
       7.4 System design
       7.5 Equipment location considerations
       7.6 Personnel safety
       7.7 Discharge rate (total flooding systems)
       7.8 Discharge time (total flooding systems)
    8 Marine loading and unloading docks
       8.1 Water supplies
       8.2 Foam concentrate
       8.3 Foam water monitors
       8.4 Below dock foam systems
    9 Aircraft hangars
       9.1 General
       9.2 Hangar partitioning
       9.3 Fire detection
       9.4 System design philosophy
       9.5 System duration
       9.6 Foam and water pumps
       9.7 Acceptable application methods
       9.8 Foam types
       9.9 Monitors
       9.10 Foam-water deluge systems
       9.11 Medium expansion systems (Type 3 hangars only)
       9.12 High expansion systems
       9.13 Headlines
       9.14 Commissioning tests
    10 Liquefied flammable gases (LNG/LPG)
       10.1 General
            10.1.1 Liquefied Natural Gas (LNG)
            10.1.2 Liquefied Petroleum Gas (LPG)
       10.2 Controlled burn-off
       10.3 Un-ignited spills
       10.4 Fire detection
       10.5 Foam properties
       10.6 Foam proportioning system
       10.7 Application techniques
    11 Commissioning, testing, and periodic inspections
       11.1 Instruction of operating personnel
       11.2 Commissioning
            11.2.1 General
            11.2.2 Visual inspection
            11.2.3 Pressure tests
            11.2.4 Tests
            11.2.5 Completion certificate
       11.3 The periodic inspection and testing of foam systems
            11.3.1 General
            11.3.2 Inspections
       11.4 Shut-down
       11.5 Maintenance
       11.6 Alterations
    Bibliography

    Abstract - (Show below) - (Hide below)

    Describes the requirements and the methods for design, installation, testing and maintenance of low, medium, and high expansion foam fire extinguishing systems.

    General Product Information - (Show below) - (Hide below)

    Committee TC 191
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    I.S. EN 50600-2-5:2016 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    EN 50600-2-5:2016 Information technology - Data centre facilities and infrastructures - Part 2-5: Security systems
    CEI EN 50600-2-5 : 2017 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    ISO/IEC TS 22237-6:2018 Information technology — Data centre facilities and infrastructures — Part 6: Security systems

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 12094-1:2003 Fixed firefighting systems - Components for gas extinguishing systems - Part 1: Requirements and test methods for electrical automatic control and delay devices
    EN 13565-1:2003+A1:2007 Fixed firefighting systems - Foam systems - Part 1: Requirements and test methods for components
    PREN 12259-12 : DRAFT 2005 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 12: PUMPS
    EN 12094-2:2003 Fixed firefighting systems - Components for gas extinguishing systems - Part 2: Requirements and test methods for non-electrical automatic control and delay devices
    EN 12259-1:1999 + A1:2001/A3:2006 FIXED FIREFIGHTING SYSTEMS - COMPONENTS FOR SPRINKLER AND WATER SPRAY SYSTEMS - PART 1: SPRINKLERS
    EN 2:1992/A1:2004 CLASSIFICATION OF FIRES
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective