• Shopping Cart
    There are no items in your cart

EN 14064-2:2010

Current

Current

The latest, up-to-date edition.

Thermal insulation products for buildings - In-situ formed loose-fill mineral wool (MW) products - Part 2: Specification for the installed products

Published date

24-02-2010

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Requirements
5 Test methods
6 Guidelines for installation
7 Installer's declaration
Annex A (normative) Lofts - Determination of installed
        insulation thickness - Pin and plate method
Annex B (normative) Masonry cavity walls - Determination
        of average cavity width
Annex C (normative) Masonry cavity walls and frame
        constructions - Coverage test box
Annex D (normative) Masonry cavity walls - Use of endoscope
        to check adequacy of fill
Annex E (normative) Guidance for the installer - Suitability
        of the building, training, pre-checks and installation
        declaration
Bibliography

This European Standard specifies the requirements for blown loose-fill mineral wool products installed in lofts, masonry cavity walls and frame constructions.This European standard is a specification for the installed insulation products.This European standard describes, when taken together with Part 1 of EN 14064, the product characteristics that are linked to the essential requirements of the EU Construction Products Directive. It also specifies the checks and tests to be used for the declarations made by the installer of the product and the rules for the evaluation of conformity.This standard does not specify the required level of a given property to be achieved by a product to demonstrate fitness for purpose in a particular application. The levels required for a given application are to be found in regulations or non-conflicting standards. For example, see the note in the scope of Part 1 of EN 14064 regarding the possibility of special water penetration tests in different Member States.Products with a declared thermal conductivity at 10 °C greater than 0,060 W/(m.K) are not covered by this standard.This European Standard does not cover factory made mineral wool products in the form of mats, batts, rolls or boards.This standard does not cover products intended for airborne sound insulation and for acoustic absorption applications.

Committee
CEN/TC 88
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

I.S. EN 14064-1:2010 THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSEFILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION
EN 13162:2012+A1:2015 Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification
PREN 14064-1 : DRAFT 2016 THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION
BS EN 14064-1:2010 Thermal insulation products for buildings. In-situ formed loose-fill mineral wool (MW) products Specification for the loose-fill products before installation
UNI EN 14064-1 : 2010 THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION
DIN EN 13162:2015-04 THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION
I.S. EN 13162:2012 THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION
EN 14064-1:2010 Thermal insulation products for buildings - In-situ formed loose-fill mineral wool (MW) products - Part 1: Specification for the loose-fill products before installation
BS EN 13162 : 2012 THERMAL INSULATION PRODUCTS FOR BUILDINGS - FACTORY MADE MINERAL WOOL (MW) PRODUCTS - SPECIFICATION
UNE-EN 13162:2013 Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification
DIN EN 14064-1:2010-06 THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION
16/30313668 DC : 0 BS EN 14064-1 - THERMAL INSULATION PRODUCTS FOR BUILDINGS - IN-SITU FORMED LOOSE-FILL MINERAL WOOL (MW) PRODUCTS - PART 1: SPECIFICATION FOR THE LOOSE-FILL PRODUCTS BEFORE INSTALLATION
UNE-EN 13162:2013+A1:2015 Thermal insulation products for buildings - Factory made mineral wool (MW) products - Specification

ISO 9229:2007 Thermal insulation Vocabulary
EN ISO 9229:2007 Thermal insulation - Vocabulary (ISO 9229:2007)
EN 823:2013 Thermal insulating products for building applications - Determination of thickness
EN ISO 6946:2017 Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods (ISO 6946:2017, Corrected version 2021-12)
ISO 10456:2007 Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values
ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.