• Shopping Cart
    There are no items in your cart

EN 1422:1997+A1:2009

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Sterilizers for medical purposes - Ethylene oxide sterilizers - Requirements and test methods

Withdrawn date

21-03-2010

Published date

13-05-2009

Sorry this product is not available in your region.

1.1This European standard specifies the minimum performance requirements and test methods of two types of sterilizers employing ethylene oxide gas as the sterilant, either as a pure gas or in admixture with other gases (whether supplied ready mixed or mixed at the point of use) in a temporarily sealed chamber.These sterilizers are intended to be used for medical, dental, pharmaceutical, veterinary and industrial or related purposes. The two types of sterilizers have been designated Type A and Type B respectively using the following criteria:-Type A sterilizers are capable of being programmed by the user;-Type B sterilizers are of limited size and provided with one or more pre-set operating cycles which cannot be varied by the user.The clauses of this standard apply to both types of sterilizer unless it is specifically indicated within the clause that it applies only to one of the types in particular.1.2This standard includes minimum performance and construction requirements for sterilizers working above or below atmospheric pressure:-To ensure that the process is capable of being used to sterilize medical products;-For the equipment and controls necessary to permit validation and monitoring of the sterilization process.1.3This standard does not specify those tests which are necessary to determine the probability of a processed product being sterile, nor the routine quality control tests required prior to release of sterile product. These topics are addressed in EN 550.1.4This standard does not specify the procedures and equipment which can be used to improve the efficacy and/or efficiency of the process before or after the sterilization cycle.1.5Considerations of operator safety are addressed in EN 61010-1: A2 and IEC 1010-2-042.1.6This standard is applicable when:a)Specified in a contract for supply of an ethylene oxide sterilizer;or,b)A sterilizer manufacturer declares compliance when intending to supply an ethylene oxide st

DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn

Standards Relationship
UNE-EN 1422:1998 Identical
BS EN 1422:1997+A1:2009 Identical
UNE-EN 1422:1998+A1:2009 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.