EN 14315-2:2013
Current
The latest, up-to-date edition.
Thermal insulating products for buildings - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 2: Specification for the installed insulation products
16-01-2013
Foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Requirements
5 In-situ measurements and calculations
6 Guidelines for installation
7 Installer's declaration
Annex A (normative) - Method of the determination of
the declared installed insulation thickness
Procedure
Annex B (normative) - Methods for the determination of
the declared installed insulation density
Annex C (normative) - Immersion method for the
determination of the declared installed insulation
density
Annex D (normative) - Suitability of the building to receive
the insulation product
Annex E (normative) - Installation guidelines
Bibliography
This European Standard specifies requirements for in-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products when applied to walls, ceilings, roofs, suspended ceilings and floors.This Part 2 of this European Standard is a specification for the installed insulation product.This Part 2 of this European Standard describes, when taken together with Part 1 of EN 14315, the product characteristics that are linked to the essential requirements of the EU Construction Products Directive. It also specifies the checks and tests to be used for the declarations made by the installer of the product.This European Standard does not specify the required levels of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards.This European Standard does not cover factory made rigid polyurethane (PUR) or polyisocyanurate (PIR) foam products or in-situ products intended to be used for the insulation of building equipment and industrial installations.NOTEFoam products are either called flexible or rigid. The flexible products are used in upholstery and mattresses and are characterised by their ability to deflect, support and recover to their original thickness continually during their in-use phase. Those that are not flexible are termed rigid and do not possess these flexible characteristics. They are mostly used for thermal insulation purposes and vary widely in their compression strength values. Once the cell structure is crushed in a rigid foam, it does not recover its thickness fully. Some of these rigid foams are very low in density with very low compression strengths and are sometimes described "commercially" as "soft foams" or "semi-rigid" foams. This note has been included to clarify that all foams with such descriptions are covered by this standard’s used of the term rigid foam.
Committee |
CEN/TC 88
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
UNI EN 14315-2 : 2013 | Identical |
NF EN 14315-2 : 2013 | Identical |
NS EN 14315-2 : 2013 | Identical |
NBN EN 14315-2 : 2013 | Identical |
BS EN 14315-2:2013 | Identical |
DIN EN 14315-2:2013-04 | Identical |
I.S. EN 14315-2:2013 | Identical |
PN EN 14315-2 : 2013 | Identical |
NEN EN 14315-2 : 2013 | Identical |
UNE-EN 14315-2:2013 | Identical |
SN EN 14315-2 : 2013 | Identical |
I.S. EN 14315-1:2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
ASTM C 1848 : 2017 | Standard Practice for Installation of High-Pressure Spray Polyurethane Foam Insulation for the Building Enclosure |
DIN EN 14315-1:2013-04 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
UNI EN 14315-1 : 2013 | THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED SPRAYED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM SPRAY SYSTEM BEFORE INSTALLATION |
BS EN 14315-1:2013 | Thermal insulating products for buildings. In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products Specification for the rigid foam spray system before installation |
EN 14315-1:2013 | Thermal insulating products for buildings - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam spray system before installation |
UNE-EN 14315-1:2013 | Thermal insulating products for buildings. In-situ formed sprayed rigid polyurethane foam (PUR) products. Part 1: Specification for the rigid foam spray system before installation |
ISO 9229:2007 | Thermal insulation Vocabulary |
EN ISO 9229:2007 | Thermal insulation - Vocabulary (ISO 9229:2007) |
EN 14315-1:2013 | Thermal insulating products for buildings - In-situ formed sprayed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam spray system before installation |
EN 1602:2013 | Thermal insulating products for building applications - Determination of the apparent density |
EN ISO 6946:2017 | Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods (ISO 6946:2017, Corrected version 2021-12) |
ISO 10456:2007 | Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values |
ISO 6946:2017 | Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods |