• There are no items in your cart

EN 14318-2:2013

Current

Current

The latest, up-to-date edition.

Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 2: Specification for the installed insulation products

Published date

16-01-2013

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms, definitions, symbols and abbreviations
4 Requirements
5 In-situ measurements and calculations
6 Guidelines for installation
7 Installer's declaration
Annex A (normative) - Method for the determination of
        the declared installed insulation thickness:
        Average cavity width
Annex B (normative) - Suitability of the building to
        receive the insulation product
Annex C (normative) - Control of the passage of water
        vapour in insulated masonry cavities
Annex D (normative) - Installation guidelines
Bibliography

This European Standard specifies requirements for in-situ formed dispensed polyurethane foam (PUR) and polyisocyanurate (PIR) foam products when installed into cavity walls.This Part 2 of this European Standard is a specification for the installed insulation product.This Part 2 of this European Standard describes, when taken together with Part 1 of EN 14318, the product characteristics linked to the essential requirements of the EU Construction Products Directive. It also specifies the checks and tests to be used for the declarations made by the installer of the product.This European Standard does not specify the required levels of all properties to be achieved by a product to demonstrate fitness for purpose in a particular application. The required levels are to be found in regulations or non-conflicting standards.This European Standard does not cover factory made rigid polyurethane (PUR) or polyisocyanurate (PIR) foam products or in-situ products intended to be used for the insulation of building equipment and industrial installations.NOTEFoam products are either called flexible or rigid. The flexible products are used in upholstery and mattresses and are characterised by their ability to deflect, support and recover to their original thickness continually during their in-use phase. Those that are not flexible are termed rigid and do not possess these flexible characteristics. They are mostly used for thermal insulation purposes and vary widely in their compression strength values. Once the cell structure is crushed in a rigid foam, it does not recover its thickness fully. Some of these rigid foams are very low in density with very low compression strengths and are sometimes described “commercially” as “soft foams” or “semi-rigid” foams. This note has been included to clarify that all foams with such descriptions are covered by this standard’s used of the term rigid foam.

Committee
CEN/TC 88
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

UNE-EN 14318-1:2013 Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation
UNI EN 14318-1 : 2013 THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION
BS EN 14318-1:2013 Thermal insulating products for buildings. In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products Specification for the rigid foam dispensed system before installation
EN 14318-1:2013 Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation
DIN EN 14318-1:2013-04 THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION
I.S. EN 14318-1:2013 THERMAL INSULATING PRODUCTS FOR BUILDINGS - IN-SITU FORMED DISPENSED RIGID POLYURETHANE (PUR) AND POLYISOCYANURATE (PIR) FOAM PRODUCTS - PART 1: SPECIFICATION FOR THE RIGID FOAM DISPENSED SYSTEM BEFORE INSTALLATION

ISO 9229:2007 Thermal insulation Vocabulary
EN ISO 9229:2007 Thermal insulation - Vocabulary (ISO 9229:2007)
EN ISO 6946:2017 Building components and building elements - Thermal resistance and thermal transmittance - Calculation methods (ISO 6946:2017, Corrected version 2021-12)
ISO 10456:2007 Building materials and products — Hygrothermal properties — Tabulated design values and procedures for determining declared and design thermal values
EN 14318-1:2013 Thermal insulating products for buildings - In-situ formed dispensed rigid polyurethane (PUR) and polyisocyanurate (PIR) foam products - Part 1: Specification for the rigid foam dispensed system before installation
ISO 6946:2017 Building components and building elements — Thermal resistance and thermal transmittance — Calculation methods

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.