EN 14620-4:2025

Current

Current

The latest, up-to-date edition.

Design and manufacture of site built, vertical, cylindrical, flat-bottomed tank systems for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and -196 °C - Part 4: Insulation components

Published date

30-04-2025

Sorry this product is not available in your region.

This document specifies the requirements for materials, design and installation of the insulation of refrigerated liquefied gas (RLG) storage tank systems.RLG storage tank systems store liquefied gas with a low boiling point, i.e. below normal ambient temperature.The concept of storing such products in liquid form and in non-pressurized tanks therefore depends on the combination of latent heat of vaporization and thermal insulation.Consequently, thermal insulation for RLG storage tank systems is not an ancillary part of the containment system (as for most ambient atmospheric hydrocarbon tanks) but it is an essential component and the storage tank system cannot operate without a properly designed, installed and maintained insulation system.The main functions of the insulation in RLG storage tank systems are:-to maintain the boil off due to heat in-leak at or below the specified limits;-to limit the thermal loading of the outer tank components, so to prevent both their sudden damage and premature ageing (e.g. due to external condensation and ice formation);-to prevent damage by frost heave of the foundation/soil beneath the tank base slab (in combination with the slab heating system for tanks resting at grade);-to minimize condensation and icing on the outer surfaces of the tank.A wide range of insulation materials is available. However, the material properties differ greatly amongst the various generically different materials and also within the same generic group of materials.Therefore, within the scope of this document, only general guidance on selection of materials is given.NOTEFor general guidance on selection of materials, see Annex A.This document deals with the design and manufacture of site built, vertical, cylindrical, flat-bottomed tank systems for the storage of refrigerated, liquefied gases with operating temperatures between 0 °C and −196 °C.

Committee
CEN/TC 265
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
PN-EN 14620-4:2025-09 Identical
UNE-EN 14620-4:2025 Identical
DS/EN 14620-4:2025 Identical
SS-EN 14620-4:2025 Identical
NS-EN 14620-4:2025 Identical
I.S. EN 14620-4:2025 Equivalent
BS EN 14620-4:2025 Equivalent
ÖNORM EN 14620-4:2025 10 01 Identical