• Shopping Cart
    There are no items in your cart

EN 14662-5:2005

Current

Current

The latest, up-to-date edition.

Ambient air quality - Standard method for measurement of benzene concentrations - Part 5: Diffusive sampling followed by solvent desorption and gas chromatography

Published date

18-05-2005

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative References
3 Terms and definitions
4 Method description
  4.1 Principle
  4.2 Reagents and Materials
  4.3 Apparatus
  4.4 Sampling
  4.5 Procedure
  4.6 Calculations of mass concentration of benzene
  4.7 Report
5 Determination of measurement uncertainty
  5.1 Introduction
  5.2 Parameters contributing to measurement uncertainty
6 Recommendations for use
Annex A (informative) Suppliers of charcoal-based organic
                      vapor diffusive samplers
Annex B (informative) Specific information of sampler type A
Annex C (informative) Specific information of sampler type B
Annex D (informative) Assessment of performance indicators and
                      uncertainty contributions
Annex E (informative) Performance characteristics
Bibliography

This part of EN 14662 is in accordance with the generic methodology selected as the basis of the European Union reference method for the determination of benzene in ambient air [1] for the purpose of comparison of measurement results with limit values with a one-year reference period.This part of EN 14662 gives general guidance for the sampling and analysis of benzene in air, by diffusive sampling, solvent desorption and capillary gas chromatography. This part of EN 14662 is valid for the measurement of benzene in a concentration range of approximately 0,5 mg/m3 to 50 mg/m3 in an air sample typically collected over a period of several days or several weeks. A number of devices are recommended for the sampling of benzene, each device having a different range of applicability, particularly with regard to the optimum period of exposure. The upper limit of the useful range is set by the sorptive capacity of the activated charcoal and, subject to dilution of the analysed solution, by the linear dynamic range of the gas chromatograph column and detector or by the sample splitting capability of the analytical instrumentation used. The lower limit of the useful range depends on the noise level of the detector and on blank levels of benzene and/or interfering artefacts on the sampling devices or in the carbon disulphide. Alternative sorbents to activated charcoal may be used provided that the equivalence in performance characteristics of the procedure is demonstrated.Alternative desorption solvents to carbon disulphide may be used provided that the equivalence in performance characteristics of the procedure is demonstrated.

Committee
CEN/TC 264
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 6144:2003 Gas analysis — Preparation of calibration gas mixtures — Static volumetric method
VDI 2100 Blatt 1:2008-06 Gaseous ambient air pollution measurement - Indoor air pollution measurement - Gas chromatographic determination of organic compounds - Fundamentals
EN 838:2010 Workplace exposure - Procedures for measuring gases and vapours using diffusive samplers - Requirements and test methods
ISO 5725-3:1994 Accuracy (trueness and precision) of measurement methods and results — Part 3: Intermediate measures of the precision of a standard measurement method
VDI 2100 Blatt 3:2011-10 Determination of gaseous compounds in ambient air - Determination of indoor air pollutants - Gas chromatographic determination of organic compounds - Active sampling by accumulation on adsorbents - Thermal desorption
ISO Guide 30:2015 Reference materials — Selected terms and definitions
ISO 6145-10:2002 Gas analysis — Preparation of calibration gas mixtures using dynamic volumetric methods — Part 10: Permeation method
EN 13528-2:2002 Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 2: Specific requirements and test methods
ISO 5725-2:1994 Accuracy (trueness and precision) of measurement methods and results Part 2: Basic method for the determination of repeatability and reproducibility of a standard measurement method
ENV 13005 : DRAFT 1999 GUIDE TO THE EXPRESSION OF UNCERTAINTY IN MEASUREMENT
EN 13528-3:2003 Ambient air quality - Diffusive samplers for the determination of concentrations of gases and vapours - Requirements and test methods - Part 3: Guide to selection, use and maintenance
ISO 3534-1:2006 Statistics — Vocabulary and symbols — Part 1: General statistical terms and terms used in probability

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.