EN 15280:2013
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Evaluation of a.c. corrosion likelihood of buried pipelines applicable to cathodically protected pipelines
14-08-2013
01-09-2017
Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Cathodic protection personnel competence
5 Assessment of the a.c. influence
6 Evaluation of the likelihood of a.c. corrosion
7 Acceptable interference levels
8 Measurement techniques
9 Mitigation measures
10 Commissioning
11 Monitoring and maintenance
Annex A (informative) - Simplified description of the
a.c. corrosion phenomenon
Annex B (informative) - Coupons and probes
Annex C (informative) - Coulometric oxidation
Annex D (informative) - Influence of soil characteristics
on the a.c. corrosion process
Annex E (informative) - Other criteria that have been
used in the presence of a.c. influence
Annex F (informative) - Parameters to take into account
to choose a d.c. decoupling device
Annex G (informative) - Method to determine the reference
electrode location to remote earth
Bibliography
This European Standard is applicable to buried cathodically protected metallic structures that are influenced by a.c. traction systems and/or a.c. power lines.In this document, a buried pipeline (or structure) is a buried or immersed pipeline (or structure), as defined in EN 12954.In the presence of a.c. interference, the protection criteria given in EN 12954:2001, Table 1, are not sufficient to demonstrate that the steel is being protected against corrosion.This European Standard provides limits, measurement procedures, mitigation measures and information to deal with long term a.c. interference for a.c voltages at frequencies between 16,7 Hz and 60 Hz and the evaluation of a.c. corrosion likelihood.This European Standard deals with the possibility of a.c. corrosion of metallic pipelines due to a.c. interferences caused by inductive, conductive or capacitive coupling with a.c. power systems and the maximum tolerable limits of these interference effects. It takes into account the fact that this is a long-term effect, which occurs during normal operating conditions of the a.c. power system.This European Standard does not cover the safety issues associated with a.c. voltages on pipelines. These are covered in national standards and regulations (see EN 50443).
| Committee |
CEN/TC 219
|
| DevelopmentNote |
Supersedes CEN/TS 15280 & PREN 15280. (09/2013)
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| BS EN 15280:2013 | Identical |
| NF EN 15280 : 2013 | Identical |
| I.S. EN 15280:2013 | Identical |
| PN EN 15280 : 2013 | Identical |
| NBN EN 15280 : 2013 | Identical |
| NS EN 15280 : 2013 | Identical |
| NEN EN 15280 : 2013 | Identical |
| DIN EN 15280:2013-12 | Identical |
| UNE-EN 15280:2014 | Identical |