EN 15727:2010
Current
The latest, up-to-date edition.
Ventilation for buildings - Ducts and ductwork components, leakage classification and testing
26-05-2010
Foreword
Introduction
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Instrumentation
5 Leakage
6 Test rig specifications
7 Test procedure
8 Test report
Bibliography
This European Standard applies to technical ductwork products, intended for installation in ductwork conforming to EN 1505 and EN 1506, used in air conditioning and ventilation systems defined in the scope of CEN/TC 156. This document specifies the leakage requirements for technical ductwork products, i.e. components in the ductwork that has more functions than conveying air, such as sound attenuators, filter boxes and duct fans, etc. The following products are not within the scope of this document:-ductwork components like bends, reducers and T-pieces. EN 12237 and EN 1507 apply;-flexible ducts according to EN 13180;-ducts made of insulation ductboards according to EN 13403;-dampers according to EN 1751;-air handling units according to EN 1886.This document is a parallel standard to EN 12237, EN 1507 and EN 1751, based on the same leakage classification.
Committee |
CEN/TC 156
|
DevelopmentNote |
Supersedes PREN 15727. (11/2010)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
DIN EN 15727:2010-10 | Identical |
SN EN 15727 : 2010 | Identical |
PN EN 15727 : 2010 | Identical |
NF EN 15727 : 2010 | Identical |
NS EN 15727 : 2010 | Identical |
BS EN 15727:2010 | Identical |
NBN EN 15727 : 2010 | Identical |
UNI EN 15727 : 2010 | Identical |
NEN EN 15727 : 2010 | Identical |
I.S. EN 15727:2010 | Identical |
UNE-EN 15727:2010 | Identical |
S.R. CEN/TR 16798-4:2017 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 4: INTERPRETATION OF THE REQUIREMENTS IN EN 16798-3 - FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS (MODULES M5-1, M5-4) |
EN 16798-3:2017 | Energy performance of buildings - Ventilation for buildings - Part 3: For non-residential buildings - Performance requirements for ventilation and room-conditioning systems (Modules M5-1, M5-4) |
CEN/TR 16798-4:2017 | Energy performance of buildings - Ventilation for buildings - Part 4: Interpretation of the requirements in EN 16798- 3 - For non-residential buildings - Performance requirements for ventilation and room-conditioning systems(Modules M5-1, M5-4) |
15/30297468 DC : 0 | BS EN 16798-3 - ENERGY PERFORMANCE OF BUILDINGS - PART 3: VENTILATION FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS |
PD CEN/TR 16798-4:2017 | Energy performance of buildings. Ventilation for buildings Interpretation of the requirements in EN 16798-3. For non-residential buildings. Performance requirements for ventilation and room-conditioning systems(Modules M5-1, M5-4) |
DIN EN 1751:2014-06 | Ventilation for buildings - Air terminal devices - Aerodynamic testing of damper and valves |
I.S. EN 1751:2014 | VENTILATION FOR BUILDINGS - AIR TERMINAL DEVICES - AERODYNAMIC TESTING OF DAMPER AND VALVES |
DIN EN 1751:1999-01 | VENTILATION FOR BUILDINGS - AIR TERMINAL DEVICES - AERODYNAMIC TESTING OF DAMPERS AND VALVES |
UNE-EN 1751:2014 | Ventilation for buildings - Air terminal devices - Aerodynamic testing of damper and valves |
UNI EN 1751 : 2014 | VENTILATION FOR BUILDINGS - AIR TERMINAL DEVICES - AERODYNAMIC TESTING OF DAMPER AND VALVES |
EN 1751:2014 | Ventilation for buildings - Air terminal devices - Aerodynamic testing of damper and valves |
DIN EN 16798-3:2017-11 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 3: FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS (MODULES M5-1, M5-4) |
I.S. EN 16798-3:2017 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 3: FOR NON-RESIDENTIAL BUILDINGS - PERFORMANCE REQUIREMENTS FOR VENTILATION AND ROOM-CONDITIONING SYSTEMS (MODULES M5-1, M5-4) |
BS EN 1751:2014 | Ventilation for buildings. Air terminal devices. Aerodynamic testing of damper and valves |
EN 14239:2004 | Ventilation for buildings - Ductwork - Measurement of ductwork surface area |
EN 1886:2007 | Ventilation for buildings - Air handling units - Mechanical performance |
EN 1507:2006 | Ventilation for buildings - Sheet metal air ducts with rectangular section - Requirements for strength and leakage |
EN 1505:1997 | Ventilation for buildings - Sheet metal air ducts and fittings with rectangular cross section - Dimensions |
EN 13403:2003 | Ventilation for buildings - Non-metallic ducts - Ductwork made from insulation ductboards |
EN 13180:2001 | Ventilation for buildings - Ductwork - Dimensions and mechanical requirements for flexible ducts |
EN 12792:2003 | Ventilation for buildings - Symbols, terminology and graphical symbols |
EN 1506:2007 | Ventilation for buildings - Sheet metal air ducts and fittings with circular cross-section - Dimensions |
EN 12237:2003 | Ventilation for buildings - Ductwork - Strength and leakage of circular sheet metal ducts |
EN 1751:2014 | Ventilation for buildings - Air terminal devices - Aerodynamic testing of damper and valves |
EN 12097:2006 | Ventilation for Buildings - Ductwork - Requirements for ductwork components to facilitate maintenance of ductwork systems |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.