• Shopping Cart
    There are no items in your cart

EN 15882-2:2015

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Extended application of results from fire resistance tests for service installations - Part 2: Fire dampers

Withdrawn date

31-10-2015

Published date

15-04-2015

Sorry this product is not available in your region.

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Determination of worst case
5 Conditions and application rules
6 Influence of parameters and factors on fire
  damper performance
7 Critical parameters and factors
8 Methodology
9 Report of the extended application analysis
Bibliography

This European Standard provides guidance and rules to notified bodies (for fire dampers) to allow them to produce/validate an extended field of application report for fire dampers. This standard identifies the parameters that affect the fire resistance of dampers. It also identifies the factors that need to be considered when deciding whether, or by how much, the parameter can be extended when contemplating the fire resistance performance of an untested, or untestable variation in the construction.This European Standard explains the principles behind how a conclusion on the influence of specific parameters/constructional details relating to the relevant criteria (E,I,S) can be achieved.This European Standard does not cover dampers used for smoke control.This European Standard only applies to extended fields of application based on tests successfully undertaken to EN 1366-2. Only test reports that have a total test time where the criteria are fulfilled that is in excess of the required classification period by a margin of either 10 % or 12 min, whichever is the least, are to be considered. Each classification (E,I,S) is to be considered individually - consequently E (134 min achieved) may be extended, but EI (61 min achieved) may not be extended for a classification of EI60.Additionally, leakage determined during such tests is to be at least 10 % below the leakage limits for E, or for E-S, dependent on classification achieved, given in EN 13501-3 before the EXAP rules can be applied. The 10 % below the leakage limits is to be fulfilled for the extended period in addition to the classification period.By application of this European Standard, it should be possible to identify what specifications should be tested to maximize the field of application. Some information on test programmes is given for guidance purposes.

Committee
CEN/TC 127
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.