• EN 15882-2:2015

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Extended application of results from fire resistance tests for service installations - Part 2: Fire dampers

    Available format(s): 

    Withdrawn date:  30-10-2015

    Language(s): 

    Published date:  14-04-2015

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    Introduction
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Determination of worst case
    5 Conditions and application rules
    6 Influence of parameters and factors on fire
      damper performance
    7 Critical parameters and factors
    8 Methodology
    9 Report of the extended application analysis
    Bibliography

    Abstract - (Show below) - (Hide below)

    This European Standard provides guidance and rules to notified bodies (for fire dampers) to allow them to produce/validate an extended field of application report for fire dampers. This standard identifies the parameters that affect the fire resistance of dampers. It also identifies the factors that need to be considered when deciding whether, or by how much, the parameter can be extended when contemplating the fire resistance performance of an untested, or untestable variation in the construction.This European Standard explains the principles behind how a conclusion on the influence of specific parameters/constructional details relating to the relevant criteria (E,I,S) can be achieved.This European Standard does not cover dampers used for smoke control.This European Standard only applies to extended fields of application based on tests successfully undertaken to EN 1366-2. Only test reports that have a total test time where the criteria are fulfilled that is in excess of the required classification period by a margin of either 10 % or 12 min, whichever is the least, are to be considered. Each classification (E,I,S) is to be considered individually - consequently E (134 min achieved) may be extended, but EI (61 min achieved) may not be extended for a classification of EI60.Additionally, leakage determined during such tests is to be at least 10 % below the leakage limits for E, or for E-S, dependent on classification achieved, given in EN 13501-3 before the EXAP rules can be applied. The 10 % below the leakage limits is to be fulfilled for the extended period in addition to the classification period.By application of this European Standard, it should be possible to identify what specifications should be tested to maximize the field of application. Some information on test programmes is given for guidance purposes.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 127
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Withdrawn

    Standards Referenced By This Book - (Show below) - (Hide below)

    PREN 15650 : DRAFT 2017 VENTILATION FOR BUILDINGS - FIRE DAMPERS
    ISO 21927-8:2017 Smoke and heat control systems — Part 8: Smoke control dampers
    17/30296747 DC : 0 BS EN 15650 - VENTILATION FOR BUILDINGS - FIRE DAMPERS
    BS ISO 21927-8:2017 Smoke and heat control systems Smoke control dampers

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 15882-1:2011+A1:2017 Extended application of results from fire resistance tests for service installations - Part 1: Ducts
    EN 1366-1:2014 Fire resistance tests for service installations - Part 1: Ventilation ducts
    EN 13501-3:2005+A1:2009 Fire classification of construction products and building elements - Part 3: Classification using data from fire resistance tests on products and elements used in building service installations: fire resisting ducts and fire dampers
    EN 1363-1:2012 Fire resistance tests - Part 1: General Requirements
    EN 1366-2:2015 Fire resistance tests for service installations - Part 2: Fire dampers
    ISO 10294-4:2001 Fire resistance tests Fire dampers for air distribution systems Part 4: Test of thermal release mechanism
    ISO 10294-1:1996 Fire resistance tests Fire dampers for air distribution systems Part 1: Test method