• Shopping Cart
    There are no items in your cart

EN 16215:2012

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by

Animal feeding stuffs - Determination of dioxins and dioxin-like PCBs by GC/HRMS and of indicator PCBs by GC/HRMS

Superseded date

14-01-2020

Superseded by

EN 16215:2020

Published date

25-04-2012

Sorry this product is not available in your region.

Foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Principle
5 Reagents
6 Apparatus
7 Sampling
8 Preparation of test sample
9 Procedure
10 Extraction
11 Clean up
12 Module D: Gas chromatograph-high resolution mass
   spectrometer (GC-HRMS)
13 Calculation and expression of results
14 Precision
15 Test report
Annex A (informative) - Description of PTV injection system
Annex B (informative) - Description of standards and
        concentration of the standard solutions
Annex C (informative) - Example of automated procedure
Annex D (informative) - Mass spectrometer (MS)
Annex E (informative) - Use of additional clean up after
        fractionation using a small multi-layer silica column
Bibliography

This European Standard is applicable to the determination of polychlorinated dibenzo-p-dioxins (PCDDs), polychlorinated dibenzofurans (PCDFs), (together termed ‘dioxins’ (PCDD/Fs)) and dioxin-like PCBs and non dioxin-like PCBs (dl-PCBs and ndl-PCBs) in animal feeding stuffs. Collaborative studies have been carried out. The method is suitable for the determination of dioxins, dl-PCBs and ndl-PCBs at the appropriate MRL in compound feed and ingredients e.g. oil, mineral clay. The method is applicable to samples containing residues of one or more of the following dioxins, dioxin-like PCBs and indicator PCBs. The limit of quantification (LOQ) for the relevant individual congeners of dioxins/furans is 0,05 pg/g (OCDD/F = 0,1 pg/g), of non-ortho PCBs 0,05 pg/g, of mono-ortho PCBs 10 pg/g and of indicator PCBs 100 pg/g.For determination of dioxins and dioxin-like PCBs, the procedure can be used as confirmatory method as defined by Commission Regulation (EC) No 152/2009 for dioxins and dl-PCB in feed [1]. Confirmatory methods are high-resolution gas chromatography/high resolution mass spectrometry (HRGC/HRMS) methods. If only the analysis of indicator PCBs is required, a GC-LRMS method can be used (e.g. EN 15741 Animal feeding stuffs - Determination of OC-pesticides and PCBs by GC/MS [7] and EN 15742 Animal feeding stuffs - Determination of OC-pesticides and PCBs by GC/ECD [8]) provided that appropriate analytical performance criteria are met in the relevant range for the matrix of interest.This European Standard is split into four modules each describing a part of the whole procedure (see Figure 1 and Figure 2) to be followed:a)Module A:Description of standards which might be used;b)Module B:Description of extraction procedures;c)Module C:Description of clean up procedures;d)Module D: GC/HRMS determination.Each module describes a part of the whole method as well as, when applicable, alternatives which should be equivalent. Each module has to be regarded as an example. Combining modules and/or alternatives gives a highly flexible procedure which is "performance based". It is permitted to modify the method if all performance criteria laid down in Commission Regulation (EC) No 152/2009 [1] are met.Any deviation of the described method, combination of modules needs to be recorded as part of the QA/QC procedures of accredited laboratories and should be available on request.

Committee
CEN/TC 327
DevelopmentNote
Supersedes PREN 16215. (05/2012)
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
NS EN 16215 : 2012 Identical
SN EN 16215 : 2012 Identical
UNE-EN 16215:2012 Identical
DIN EN 16215:2012-07 Identical
NBN EN 16215 : 2012 Identical
DIN EN 16215:2018-10 (Draft) Identical
BS EN 16215:2012 Identical
SS-EN 16215:2012 Identical
NEN EN 16215 : 2012 Identical
I.S. EN 16215:2012 Identical
NF EN 16215 : 2012 Identical
PN EN 16215 : 2012 Identical
UNI EN 16215 : 2012 Identical
ONORM EN 16215 : 2012 Identical

ISO 6497:2002 Animal feeding stuffs Sampling
PREN ISO 6498 : DRAFT 2009 ANIMAL FEEDING STUFFS - GUIDELINES FOR SAMPLE PREPARATION
EN 15742:2009 Animal feeding stuffs - Determination of OC-pesticides and PCB’s by GC/ECD
EN ISO 6497:2005 Animal feeding stuffs - Sampling (ISO 6497:2002)
ISO 6498:2012 Animal feeding stuffs — Guidelines for sample preparation
EN 15741:2009 Animal feeding stuffs - Determination of OC-pesticides and PCB’s by GC/MS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.