• EN 1627:2011

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Requirements and classification

    Available format(s): 

    Superseded date:  10-06-2021

    Language(s): 

    Published date:  11-05-2011

    Publisher:  Comite Europeen de Normalisation

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Foreword
    1 Scope
    2 Normative references
    3 Terms and definitions
    4 Resistance classification
    5 Infillings
    6 Hardware
    7 Mechanical strength
    8 Manual burglary attempts
    9 Classification report
    10 Installation
    11 Test specimens
    Annex A (informative) - Recommendations for the
            contents of the manufacturer's installation
            instructions
    Annex B (normative) - Requirements for locks and
            hardware outside the scope of the standards
            listed in Table 2
    Annex C (informative) - Resistance classes -
            Classification according to EN 1627
    Annex D (normative) - Field of application
    Annex E (normative) - Procedure for testing and
            classification
    Bibliography

    Abstract - (Show below) - (Hide below)

    This European Standard specifies requirements and classification systems for burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions. It also covers products that include items such as letter plates or ventilation grilles. It specifies requirements for the burglar resistance of a construction product (as defined in 3.1 of this standard).This European Standard does not directly cover the resistance of locks and cylinders to attack with picking tools. It also does not cover precast concrete elements.It also does not cover the attack of electric, electronic and electromagnetic operated burglar resistant construction products using attack methods that might defeat these characteristics. NOTE 1The mechanical parts of electric, electronic and electromagnetic operated burglar resistant construction products may be tested in electrical powerless condition.This European Standard does not apply to doors, gates and barriers, intended for installation in areas in the reach of persons, and for which the main intended uses are giving safe access for goods and vehicles accompanied or driven by persons in industrial, commercial or residential premises, as covered by EN 13241-1.NOTE 2Construction products that can be reached or driven through by vehicles should be protected by appropriate measures such as barriers, extensible ramps, etc.

    General Product Information - (Show below) - (Hide below)

    Committee CEN/TC 33
    Development Note Supersedes ENV 1627. (05/2011)
    Document Type Standard
    Publisher Comite Europeen de Normalisation
    Status Superseded
    Superseded By
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    14/30302455 DC : 0 BS EN 13659 - SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
    BS EN 1629 : 2011 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE UNDER DYNAMIC LOADING
    PREN 13126-15 : DRAFT 2017 QUINCAILLERIE POUR LE BATIMENT - FERRURES DE DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 15: ROLLERS FOR HORIZONTAL SLIDING AND HARDWARE FOR SLIDING FOLDING WINDOWS
    12/30263172 DC : 0 BS EN 1935 - BUILDING HARDWARE - SINGLE-AXIS HINGES - REQUIREMENTS AND TEST METHODS
    PREN 13126-8 : DRAFT 2016 BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 8: REQUIREMENTS AND TEST METHODS FOR TILT & TURN, TILT-FIRST AND TURN-ONLY HARDWARE
    CEI UNI EN 50518-1 : 2015 MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS
    17/30335089 DC : 0 BS EN 13126-6 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 6: VARIABLE GEOMETRY STAY HINGES (WITH OR WITHOUT A FRICTION STAY)
    PREN 13126-6 : DRAFT 2017 BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 6: VARIABLE GEOMETRY STAY HINGES (WITH OR WITHOUT A FRICTION STAY)
    PREN 50600-2-5 : DRAFT 2012 BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    I.S. EN 50600-2-5:2016 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    I.S. EN 1629:2011 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE UNDER DYNAMIC LOADING
    18/30361306 DC : 0 BS EN 13126-16 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 16: HARDWARE FOR LIFT AND SLIDE WINDOWS
    UNI CEI EN 50518-1 : 2014 MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS
    BS EN 13126-8:2017 Building hardware. Hardware for windows and door height windows Requirements and test methods for Tilt and Turn, Tilt-First and Turn-Only hardware
    CEN/TS 419261:2015 Security requirements for trustworthy systems managing certificates and time-stamps
    EN 50518-1:2013 MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS
    EN 50600-2-5:2016 Information technology - Data centre facilities and infrastructures - Part 2-5: Security systems
    DIN EN 1628:2016-03 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading (includes Amendment A1:2015)
    PREN 1935 : DRAFT 2012 BUILDING HARDWARE - SINGLE-AXIS HINGES - REQUIREMENTS AND TEST METHODS
    PD CEN/TS 419261:2015 Security requirements for trustworthy systems managing certificates and time-stamps
    PREN 14351-2 : DRAFT 2014 WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS
    EN 1630:2011+A1:2015 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE TO MANUAL BURGLARY ATTEMPTS
    BS EN 1630 : 2011 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE TO MANUAL BURGLARY ATTEMPTS
    PREN 13659 : DRAFT 2014 SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
    BS EN 16361 : 2013 POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION
    I.S. EN 16893:2018 CONSERVATION OF CULTURAL HERITAGE - SPECIFICATIONS FOR LOCATION, CONSTRUCTION AND MODIFICATION OF BUILDINGS OR ROOMS INTENDED FOR THE STORAGE OR USE OF HERITAGE COLLECTIONS
    I.S. EN 16361:2013 POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION
    UNE-EN 50518-1:2014 Monitoring and alarm receiving centre - Part 1: Location and construction requirements
    I.S. EN 13659:2015 SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
    VDI 6203:2017-05 Facade planning - Criteria, degree of difficulty, assessment
    PREN 13126-17 : DRAFT 2018 BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 17: HARDWARE FOR TILT AND SLIDE WINDOWS
    BS EN 50518-1:2013 Monitoring and alarm receiving centre Location and construction requirements
    11/30253413 DC : 0 BS EN 16361 - POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOOR SETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION WITHOUT RESISTANCE TO FIRE AND SMOKE LEAKAGE CHARACTERISTICS
    EN 1628:2011+A1:2015 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE UNDER STATIC LOADING
    DIN EN 1629:2016-03 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading (includes Amendment A1:2015)
    PREN 50518 : DRAFT 2016 MONITORING AND ALARM RECEIVING CENTRE
    DIN EN 1630:2016-03 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts (includes Amendment A1:2015)
    BS EN 1628 : 2011 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE UNDER STATIC LOADING
    I.S. EN 13126-8:2017 BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - PART 8: REQUIREMENTS AND TEST METHODS FOR TILT AND TURN, TILT-FIRST AND TURN-ONLY HARDWARE
    PREN 13126-16 : DRAFT 2018 BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 16: HARDWARE FOR LIFT AND SLIDE WINDOWS
    18/30361302 DC : 0 BS EN 13126-17 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 17: HARDWARE FOR TILT AND SLIDE WINDOWS
    16/30335086 DC : 0 BS EN 13126-8 - BUILDING HARDWARE - HARDWARE FOR WINDOWS AND DOORS HEIGHT WINDOWS - PART 8: REQUIREMENTS AND TEST METHODS FOR TILT & TURN, TILT-FIRST AND TURN-ONLY HARDWARE
    12/30274114 DC : 0 BS EN 50600-2-5 - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    CEI EN 50600-2-5 : 2017 INFORMATION TECHNOLOGY - DATA CENTRE FACILITIES AND INFRASTRUCTURES - PART 2-5: SECURITY SYSTEMS
    ISO/IEC TS 22237-6:2018 Information technology — Data centre facilities and infrastructures — Part 6: Security systems
    11/30247940 DC : 0 BS EN 50600-2-1 - ELECTROTECHNICAL ASPECT OF TELECOMMUNICATION EQUIPMENT
    15/30324474 DC : 0 BS EN 16893 - CONSERVATION OF CULTURAL HERITAGE - NEW SITES AND BUILDINGS INTENDED FOR THE STORAGE AND USE OF COLLECTIONS
    EN 13126-8:2017 Building hardware - Hardware for windows and door height windows - Part 8: Requirements and test methods for Tilt and Turn, Tilt-First and Turn-Only hardware
    UNE-EN 13659:2016 Shutters and external venetian blinds - Performance requirements including safety
    UNE-EN 1628:2011 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under static loading
    UNE-EN 1630:2011 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts
    EN 13659:2015 Shutters and external venetian blinds - Performance requirements including safety
    EN 16361:2013+A1:2016 Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation
    EN 1629:2011+A1:2015 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE UNDER DYNAMIC LOADING
    16/30299842 DC : 0 BS EN 50518 - MONITORING AND ALARM RECEIVING CENTRE
    14/30297827 DC : 0 BS EN 14351-2 - WINDOWS AND DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PART 2: INTERNAL PEDESTRIAN DOORSETS WITHOUT RESISTANCE TO FIRE AND /OR SMOKE LEAKAGE CHARACTERISTICS
    I.S. EN 1628:2011 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE UNDER STATIC LOADING
    I.S. EN 50518-1:2013 MONITORING AND ALARM RECEIVING CENTRE - PART 1: LOCATION AND CONSTRUCTION REQUIREMENTS
    UNI EN 16361 : 2013 POWER OPERATED PEDESTRIAN DOORS - PRODUCT STANDARD, PERFORMANCE CHARACTERISTICS - PEDESTRIAN DOORSETS, OTHER THAN SWING TYPE, INITIALLY DESIGNED FOR INSTALLATION WITH POWER OPERATION WITHOUT RESISTANCE TO FIRE AND SMOKE LEAKAGE CHARACTERISTICS
    S.R. CEN/TS 419261:2015 SECURITY REQUIREMENTS FOR TRUSTWORTHY SYSTEMS MANAGING CERTIFICATES AND TIME-STAMPS
    18/30361299 DC : 0 BS EN 13126-15 - QUINCAILLERIE POUR LE BATIMENT - FERRURES DE DOOR HEIGHT WINDOWS - REQUIREMENTS AND TEST METHODS - PART 15: ROLLERS FOR HORIZONTAL SLIDING AND HARDWARE FOR SLIDING FOLDING WINDOWS
    EN 16893:2018 Conservation of Cultural Heritage - Specifications for location, construction and modification of buildings or rooms intended for the storage or use of heritage collections
    I.S. EN 1630:2011 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE TO MANUAL BURGLARY ATTEMPTS
    DIN EN 13659:2015-07 SHUTTERS AND EXTERNAL VENETIAN BLINDS - PERFORMANCE REQUIREMENTS INCLUDING SAFETY
    BS EN 13659:2015 Shutters and external venetian blinds. Performance requirements including safety
    UNE-EN 16361:2014 Power operated pedestrian doors - Product standard, performance characteristics - Pedestrian doorsets, other than swing type, initially designed for installation with power operation without resistance to fire and smoke leakage characteristics
    UNE-EN 1629:2011 Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance under dynamic loading

    Standards Referencing This Book - (Show below) - (Hide below)

    EN 1906:2012 Building hardware - Lever handles and knob furniture - Requirements and test methods
    EN ISO 6508-1:2016 Metallic materials - Rockwell hardness test - Part 1: Test method (ISO 6508-1:2016)
    ISO 6508-1:2016 Metallic materials — Rockwell hardness test — Part 1: Test method
    EN 1303:2015 Building hardware - Cylinders for locks - Requirements and test methods
    EN 12519:2004 Windows and pedestrian doors - Terminology
    EN 12209:2016 Building hardware - Mechanically operated locks and locking plates - Requirements and test methods
    EN 13241-1:2003+A1:2011 Industrial, commercial and garage doors and gates - Product standard - Part 1: Products without fire resistance or smoke control characteristics
    EN 1629:2011+A1:2015 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE UNDER DYNAMIC LOADING
    EN 1630:2011+A1:2015 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE TO MANUAL BURGLARY ATTEMPTS
    EN 356:1999 Glass in building - Security glazing - Testing and classification of resistance against manual attack
    EN 1628:2011+A1:2015 PEDESTRIAN DOORSETS, WINDOWS, CURTAIN WALLING, GRILLES AND SHUTTERS - BURGLAR RESISTANCE - TEST METHOD FOR THE DETERMINATION OF RESISTANCE UNDER STATIC LOADING
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective