Pedestrian doorsets, windows, curtain walling, grilles and shutters - Burglar resistance - Test method for the determination of resistance to manual burglary attempts
23-12-2015
10-06-2021
European foreword
1 Scope
2 Normative references
3 Terms and definitions
4 Apparatus and test team
5 Test specimen
6 Procedure
7 Tool sets
8 Test report
Annex A (normative) - Tool sets
Annex B (normative) - Test sequence for manual test of
resistance classes 2 to 6
Annex C (normative) - Example of test equipment Dimensions in
mm
Annex D (informative) - Examples of mounting arrangements
Bibliography
This European Standard specifies a test method for the determination of resistance to manual burglary attempts in order to assess the burglar resistant characteristics of pedestrian doorsets, windows, curtain walling, grilles and shutters. It is applicable to the following means of opening: Turning, tilting, folding, turn-tilting, top or bottom hung, sliding (horizontally and vertically) and rolling as well as fixed constructions.This European Standard does not directly cover the resistance of locks and cylinders to attack with picking tools. It also does not cover the attack of electric, electronic and electromagnetic operated burglar resistant construction products using attack methods that might defeat these characteristics. It is acknowledged that there are two aspects to the burglar resistance performance of construction products, their normal resistance to forced operation and their ability to remain fixed to the building. Due to the limitation of reproducing the fixing methods and building construction in a laboratory environment this aspect is not fully covered by the standard. This is particularly true with products built into a building. The performance of the fixed part of the product is evaluated using a standard sub frame. It is the manufacturer´s responsibility to ensure that guidance on the fixing of the product is contained in the mounting instructions and that this guidance is suitable for the burglar resistance class claimed for the product. As with the other referenced standards this specification uses a standard sub frame and the product is mounted according to the manufacturers' instructions. An example for the contents of the manufacturer´s installation instructions is given in Annex A of EN 1627:2011. This test method does not evaluate the performance of the fixing to the building.
| Committee |
CEN/TC 33
|
| DevelopmentNote |
Supersedes ENV 1630. (05/2011) 2011 Edition Re-Issued in December 2015 & incorporates AMD 1 2015. (01/2016)
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Superseded
|
| SupersededBy | |
| Supersedes |
| Standards | Relationship |
| DIN EN 1630:2016-03 | Identical |
| PN EN 1630 : 2011 + A1 2016 | Identical |
| NEN EN 1630 : 2011 + A1 2016 | Identical |
| I.S. EN 1630:2011 | Identical |
| NS EN 1630 : 2011 + A1 2015 | Identical |
| NBN EN 1630 : 2011 + A1 2016 | Identical |
| NF EN 1630 : 2011 + A1 2016 | Identical |
| BS EN 1630 : 2011 | Identical |
| NF EN 1630:2021 | Identical |
| BS EN 1630:2011+A1:2015 | Equivalent |
| DIN EN 1630:2019-05 (Draft) | Identical |
| UNE-EN 1630:2011+A1:2017 | Identical |
| BS EN 1630:2011+A1:2015 | Identical |
| UNE-EN 1630:2011 | Identical |