• There are no items in your cart

EN 16637-3:2023

Current

Current

The latest, up-to-date edition.

Construction products: Assessment of release of dangerous substances - Part 3: Horizontal up-flow percolation test

Published date

01-11-2023

(1) This document specifies an up-flow percolation test (PT) which is applicable to determine the leaching behaviour of inorganic and non-volatile organic substances from granular construction products. The test is not suitable for substances that are volatile under ambient conditions. The construction products are subjected to percolation with water as a function of liquid to solid ratio under specified percolation conditions. The method is a once-through column leaching test.(2) This up-flow percolation test is performed under specified test conditions for construction products and does not necessarily produce results that mimic specific intended use conditions. This test method produces eluates, which can subsequently be characterized by physical, chemical and ecotoxicological methods according to existing standard methods. The results of eluate analysis are presented as a function of the liquid/solid ratio. The test results enable the distinction between different leaching behaviour.NOTE 1Volatile organic substances include the low molecular weight substances in mixtures such as mineral oil.NOTE 2It is not always possible to adjust test conditions simultaneously for inorganic and organic substances. Test conditions can also vary between different groups of organic substances. Test conditions for organic substances are generally more stringent than those for inorganic substances. The test conditions are generally described in a way that they fit testing organic substances and are also applicable to inorganic substances depending on the set-up.NOTE 3For ecotoxicity testing, eluates representing the release of both inorganic and organic substances are needed. In this document, ecotoxicological testing is meant to include also genotoxicological testing.NOTE 4Construction products with a low hydraulic conductivity that can cause detrimental pressure build-up are not supposed to be subjected to this test.NOTE 5This procedure is generally not applicable to products that are easily biologically degradable and products reacting with the leachant, leading, for example, to excessive gas emission or excessive heat release, impermeable hydraulically bound products or products that swell in contact with water.(3) In this document the same test conditions as for prEN 17516 (CEN/TC 444/WG 1) are applied in order to allow full comparability of testing construction products and waste derived construction products to avoid double testing. The prEN 17516 test results are eligible in the context of testing construction products as well.NOTE 6If a leaching test according to prEN 17516 has been performed, additional prEN 16637 3 testing does not need to be carried out.

Committee
CEN/TC 351
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current

Standards Relationship
DS/EN 16637-3:2023 Identical
PNE-EN 16637-3 Identical
ÖNORM EN 16637-3:2024 02 15 Identical
PN-EN 16637-3:2024-05 Identical

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.