![header thumbnail](/images/img-default-logo.png)
EN 16798-15:2017
Current
The latest, up-to-date edition.
![header thumbnail](/images/img-default-logo.png)
Energy performance of buildings - Ventilation for buildings - Part 15: Calculation of cooling systems (Module M4-7) - Storage
14-06-2017
This European Standard specifies a calculation method for the energy performance of storage systems used for ventilation systems. It takes into account the energy performance of storage systems using water from phase change material (PCM) to store cooling energy. This standard presents a general method applicable to the different technologies of water-based storage systems or PCM related controls systems. It does not cover the cooling emission, distribution and generation that are covered by EN 15316 2, EN 15316 3 and EN 16798-13 respectively.The standard covers typically hourly time steps but can be adapted to different time steps accordingly with the scenarios used for energy use and energy delivered or to bin method.A simplified method is provided for monthly or annual time step.This standard does not cover:-the cooling emission, distribution and generation systems; or-sizing or inspection of such storage systems.Table 1 shows the relative position of this standard within the set of EPB standards in the context of the modular structure as set out in prEN ISO 52000 1:2015.NOTE 1In prCEN ISO/TR 52000 2 the same table can be found, with, for each module, the numbers of the relevant EPB standards and accompanying technical reports that are published or in preparation.NOTE 2The modules represent EPB standards, although one EPB standard might cover more than one module and one module might be covered by more than one EPB standard, for instance a simplified and a detailed method respectively. See also Clause 2 and Tables A.1 and B.1.Table 1 - Position of this standard (in casu M4-7) within the EPB set of standards...
Committee |
CEN/TC 156
|
DevelopmentNote |
Supersedes PREN 16798-15. (06/2017)
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Current
|
Standards | Relationship |
NF EN 16798-15 : 2017 | Identical |
BS EN 16798-15:2017 | Identical |
I.S. EN 16798-15:2017 | Identical |
SS-EN 16798-15:2017 | Identical |
NS EN 16798-15 : 2017 | Identical |
DIN EN 16798-15 E : 2017 | Identical |
ONORM EN 16798-15 : 2017 | Identical |
DIN EN 16798-15:2017-11 | Identical |
PN EN 16798-15 : 2017 | Identical |
UNE-EN 16798-15:2018 | Identical |
NEN EN 16798-15 : 2017 | Identical |
UNI EN 16798-15 : 2018 | Identical |
15/30325699 DC : 0 | BS EN ISO 52000-1 - ENERGY PERFORMANCE OF BUILDINGS - OVERARCHING EPB ASSESSMENT - PART 1: GENERAL FRAMEWORK AND PROCEDURES |
I.S. EN ISO 52000-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - OVERARCHING EPB ASSESSMENT - PART 1 - GENERAL FRAMEWORK AND PROCEDURES (ISO 52000-1:2017) |
BS EN 15232-1:2017 | Energy Performance of Buildings Impact of Building Automation, Controls and Building Management. Modules M10-4,5,6,7,8,9,10 |
S.R. CEN/TR 16798-16:2017 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 16: INTERPRETATION OF THE REQUIREMENTS IN EN 16798-15 - CALCULATION OF COOLING SYSTEMS (MODULE M4-7) - STORAGE |
ISO 52000-1:2017 | Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures |
EN ISO 52000-1:2017 | Energy performance of buildings - Overarching EPB assessment - Part 1: General framework and procedures (ISO 52000-1:2017) |
EN 15232-1:2017 | Energy Performance of Buildings - Energy performance of buildings - Part 1: Impact of Building Automation, Controls and Building Management - Modules M10-4,5,6,7,8,9,10 |
CEN/TR 16798-16:2017 | Energy performance of buildings - Ventilation for buildings - Part 16: Interpretation of the requirements in EN 16798-15 - Calculation of cooling systems (Module M4-7) - Storage |
I.S. EN 15232-1:2017 | ENERGY PERFORMANCE OF BUILDINGS - ENERGY PERFORMANCE OF BUILDINGS - PART 1: IMPACT OF BUILDING AUTOMATION, CONTROLS AND BUILDING MANAGEMENT - MODULES M10-4, 5, 6, 7, 8, 9, 10 |
S.R. CEN/TR 16798-10:2017 | ENERGY PERFORMANCE OF BUILDINGS - VENTILATION FOR BUILDINGS - PART 10: INTERPRETATION OF THE REQUIREMENTS IN EN 16798-9 - CALCULATION METHODS FOR ENERGY REQUIREMENTS OF COOLING SYSTEMS (MODULE M4-1,M4-4, M4-9) - GENERAL |
CEN/TR 16798-10:2017 | Energy performance of buildings - Ventilation for buildings - Part 10: Interpretation of the requirements in EN 16798-9 - Calculation methods for energy requirements of cooling systems (Module M4-1,M4-4, M4-9) - General |
CEN/TS 16629:2014 | Energy Performance of Buildings - Detailed Technical Rules for the set of EPB-standards |
EN 15316-3:2017 | Energy performance of buildings - Method for calculation of system energy requirements and system efficiencies - Part 3: Space distribution systems (DHW, heating and cooling), Module M3-6, M4-6, M8-6 |
CEN/TS 16628:2014 | Energy Performance of Buildings - Basic Principles for the set of EPB standards |
CEN ISO/TR 52000-2:2017 | Energy performance of buildings - Overarching EPB assessment - Part 2: Explanation and justification of ISO 52000-1 (ISO/TR 52000-2:2017) |
EN 16798-9:2017 | Energy performance of buildings - Ventilation for buildings - Part 9: Calculation methods for energy requirements of cooling systems (Modules M4-1, M4-4, M4-9) - General |
CEN/TR 16798-16:2017 | Energy performance of buildings - Ventilation for buildings - Part 16: Interpretation of the requirements in EN 16798-15 - Calculation of cooling systems (Module M4-7) - Storage |
ISO 52000-1:2017 | Energy performance of buildings — Overarching EPB assessment — Part 1: General framework and procedures |
EN ISO 52000-1:2017 | Energy performance of buildings - Overarching EPB assessment - Part 1: General framework and procedures (ISO 52000-1:2017) |
EN ISO 52010-1:2017 | Energy performance of buildings - External climatic conditions - Part 1: Conversion of climatic data for energy calculations (ISO 52010-1:2017) |
ISO/TR 52000-2:2017 | Energy performance of buildings Overarching EPB assessment Part 2: Explanation and justification of ISO 52000-1 |
EN ISO 52016-1:2017 | Energy performance of buildings - Energy needs for heating and cooling, internal temperatures and sensible and latent heat loads - Part 1: Calculation procedures (ISO 52016-1:2017) |
EN 15232-1:2017 | Energy Performance of Buildings - Energy performance of buildings - Part 1: Impact of Building Automation, Controls and Building Management - Modules M10-4,5,6,7,8,9,10 |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.