• There are no items in your cart

EN 1711:2000

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Non-destructive examination of welds - Eddy current examination of welds by complex plane analysis

Withdrawn date

31-08-2000

Published date

16-02-2000

Sorry this product is not available in your region.

This standard defines eddy current examination techniques for detection of surface breaking and near surface planar imperfections, mainly in ferritic materials(weld material, heat affected zones, parent materials). The eddy current technique can also be applied to other metallic construction materials (e.g.stainless steels). The techniques can be applied to coated and uncoated objects during fabrication and in service, onshore and offshore. The examination can be carried out on all accessible surfaces and on welds of almost any configuration.

Committee
CEN/TC 121
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Withdrawn

Standards Relationship
UNE-EN 1711:2000 Identical

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.