EN 1820:2005+A1:2009
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Anaesthetic reservoir bags (ISO 5362:2000, modified)
12-08-2009
08-03-2022
Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 Prevention of electrostatic charges
6 Requirements for bags supplied sterile
7 Marking
8 Information to be supplied by the manufacturer
Annex A (informative) - Test for leakage
A.1 Principle
A.2 Apparatus
A.3 Procedure
A.4 Expression of results
Annex B (normative) - Determination of capacity
B.1 Principle
B.2 Apparatus
B.3 Procedure
B.4 Expression of results
Annex C (normative) - Test for security of attachment of
plain neck to 22 mm male conical connector
C.1 Principle
C.2 Apparatus and materials
C.3 Procedure
Annex D (normative) - Test for security of attachment of
adaptor of assembled neck to bag
D.2 Apparatus
D.3 Procedure
Annex E (normative) - Test for resistance to pressure
required to distend the bag (pressure/volume)
E.1 Principle
E.2 Apparatus
E.3 Procedure
E.4 Expression of results
Annex F (informative) - Test for resistance to pressure
required to distend the bag using air (pressure/volume)
F.1 Principle
F.2 Apparatus
F.3 Procedure
F.4 Expression of results
Annex G (informative) - Recommendations for materials
Annex ZA (informative) - Relationship between this European
Standard and the Essential Requirements of EU
Directive 93/42/EEC Medical devices
Bibliography
This European Standard specifies requirements for antistatic and non-antistatic reservoir bags for use with anaesthetic apparatus or lung-ventilator breathing systems. It includes requirements for the design of the neck, size designation, distension and, where relevant, for electrical resistance.This document is not applicable to special-purpose bags, for example bellows and self-expanding bags. Bags for use with anaesthetic gas scavenging systems are not considered to be anaesthetic reservoir bags and are thus outside the scope of this document.
| Committee |
CEN/TC 215
|
| DevelopmentNote |
2005 Edition Re-issued in August 2009 & incorporates AMD 1 2009. (09/2009)
|
| DocumentType |
Standard
|
| PublisherName |
Comite Europeen de Normalisation
|
| Status |
Superseded
|
| SupersededBy |
| Standards | Relationship |
| I.S. EN 1820:2005 | Identical |
| BS EN 1820:2005 | Identical |
| NEN EN 1820 : 2005 + A1 2009 | Identical |
| NS EN 1820 : 2005 + A1 2009 | Identical |
| NF EN 1820 : 2005 + A1 2009 | Identical |
| NBN EN 1820 : 2005 + A1 2009 | Identical |
| PN EN 1820 : 2005 + A1 2009 | Identical |
| BS EN 1820:2005+A1:2009 | Equivalent |
| UNE-EN 1820:2006+A1:2010 | Identical |
| UNE-EN 1820:2006 | Identical |
| DIN EN 1820:2009-12 | Identical |
| I.S. EN 740:1999 | ANAESTHETIC WORKSTATIONS AND THEIR MODULES - PARTICULAR REQUIREMENTS |
| BS EN 794-2:1997 | Lung ventilators Particular requirements for home care use |
| BS 5724-2.204(1999) : 1999 | ANAESTHETIC WORKSTATIONS AND THEIR MODULES - PARTICULAR REQUIREMENTS |
| DIN EN 794-1:2001-02 | LUNG VENTILATORS - PART 1: PARTICULAR REQUIREMENTS FOR CRITICAL CARE VENTILATORS |
| I.S. EN 794-3:1998 | LUNG VENTILATORS - PART 3: PARTICULAR REQUIREMENTS FOR EMERGENCY AND TRANSPORT VENTILATORS |
| PREN ISO 15883-2 : DRAFT 2002 | WASHER-DISINFECTORS - PART 2: REQUIREMENTS AND TESTS FOR WASHER-DISINFECTORS EMPLOYING THERMAL DISINFECTION FOR SURGICAL INSTRUMENTS, ANAESTHETIC EQUIPMENT, HOLLOWWARE, UTENSILS, GLASSWARE, ETC |
| BS EN 794-3 : 1999 | LUNG VENTILATORS - PART 3: PARTICULAR REQUIREMENTS FOR EMERGENCY AND TRANSPORT VENTILATORS |
| BS EN 740:1999 | Anaesthetic workstations and their modules. Particular requirements |
| EN 794-3:1998+A2:2009 | Lung ventilators - Part 3: Particular requirements for emergency and transport ventilators |
| 03/700194 DC : DRAFT FEB 2003 | BS EN ISO 15883-2 - WASHER-DISINFECTORS - PART 2: REQUIREMENTS AND TESTS FOR WASHER-DISINFECTORS EMPLOYING THERMAL DISINFECTION FOR SURGICAL INSTRUMENTS, ANAESTHETIC EQUIPMENT, HOLLOWWARE, UTENSILS, GLASSWARE, ETC. |
| DIN EN 794-3:2009-12 | Lung ventilators - Part 3: Particular requirements for emergency and transport ventilators; German version EN 794-3:1998+A2:2009 |
| UNE-EN 794-3:1999 | LUNG VENTILATORS. PART 3: PARTICULAR REQUIREMENTS FOR EMERGENCY AND TRANSPORT VENTILATORS. |
| ISO 4287:1997 | Geometrical Product Specifications (GPS) — Surface texture: Profile method — Terms, definitions and surface texture parameters |
| EN ISO 5356-1:2015 | Anaesthetic and respiratory equipment - Conical connectors - Part 1: Cones and sockets (ISO 5356-1:2015) |
| IEC 60601-1:2005+AMD1:2012 CSV | Medical electrical equipment - Part 1: General requirements for basic safety and essential performance |
| ISO 5356-1:2015 | Anaesthetic and respiratory equipment — Conical connectors — Part 1: Cones and sockets |
| EN 1041:2008+A1:2013 | Information supplied by the manufacturer of medical devices |
| ISO 11607:2003 | Packaging for terminally sterilized medical devices |
| ISO 7000:2014 | Graphical symbols for use on equipment — Registered symbols |
| ISO 4135:2001 | Anaesthetic and respiratory equipment — Vocabulary |
| EN ISO 4135:2001 | Anaesthetic and respiratory equipment - Vocabulary (ISO 4135:2001) |
| EN 980:2008 | Symbols for use in the labelling of medical devices |