• Shopping Cart
    There are no items in your cart

EN 4608-001:2019

Current

Current

The latest, up-to-date edition.

Aerospace series - Cable, electrical, fire resistant - Single and twisted multicore assembly, screened (braided) and jacketed - Operating temperatures between - 65 °C and 260 °C - Part 001: Technical specification

Published date

19-06-2019

Sorry this product is not available in your region.

This document specifies the required characteristics and test procedures for fire resistant or fire proof electrical cables for use in aircraft electrical systems. They shall be operated at a rated AC voltage of 600 V ac, a frequency of maximum 2 000 Hz and a long term temperature of up to 260 °C (ambient temperature plus temperatures rise in conductor).These cables shall also maintain a specific dielectric strength when they are subjected to a flame of 1 100 °C after five (5) minutes (fire resistant) or 15 minutes (fire proof) exposure.

Committee
ASD-STAN
DocumentType
Standard
PublisherName
Comite Europeen de Normalisation
Status
Current
Supersedes

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.