EN 4612-012:2011
Superseded
A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.
View Superseded by
Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 012: Nickel plated copper - Operating temperatures, between - 65 °C and 150 °C - Dual extruded wall for open applications, with jacket and screen (braid) - UV laser printable - Product standard
11-09-2019
19-10-2011
Foreword
1 Scope
2 Normative references
3 Terms, definitions and symbols
4 Materials and construction
5 Required characteristics
6 Quality assurance
7 Designation
8 Identification and marking
9 Packaging, labelling and delivery lengths
10 Technical specification
Annex A (normative) - Formulae for calculating braid details
This standard specifies the characteristics of UV laser printable jacket, silver plated copper conductor, electrical cables Crosslinked Ethylene Tetra Fluoro Ethylene co-polymer (XLETFE) family for use in the on board electrical systems of aircraft at operating temperatures between - 65 °C and 150 °C, operating at voltages not exceeding 600 V r.m.s and frequencies not exceeding 2 000 Hz. These cables are suitable for airframe use without additional protection. In case of conflict between this standard and other referenced documents the requirements of this standard shall take precedence.
Committee |
ASD-STAN
|
DocumentType |
Standard
|
PublisherName |
Comite Europeen de Normalisation
|
Status |
Superseded
|
SupersededBy |
Standards | Relationship |
ONORM EN 4612-012 : 2012 | Identical |
NF EN 4612-012 : 2012 | Identical |
NBN EN 4612-012 : 2011 | Identical |
NEN EN 4612-012 : 2011 | Identical |
NS EN 4612-012 : 2011 | Identical |
I.S. EN 4612-012:2011 | Identical |
PN EN 4612-012 : 2012 | Identical |
SN EN 4612-012 : 2012 | Identical |
UNI EN 4612-012 : 2012 | Identical |
UNE-EN 4612-012:2011 | Identical |
BS EN 4612-012:2011 | Identical |
DIN EN 4612-012:2012-03 | Identical |
DIN EN 4612-012:2019-05 (Draft) | Identical |
EN 2235:2015 | Aerospace series - Single and multicore electrical cables, screened and jacketed - Technical specification |
EN 2083:2001 | Aerospace series - Copper and copper alloys conductors for electrical cables - Product standard |
PREN 4611-007 : 200P1 | AEROSPACE SERIES - CABLES, ELECTRICAL, FOR GENERAL PURPOSE, SINGLE AND MULTICORE ASSEMBLY - XLETFE FAMILY - PART 007: NICKEL PLATED COPPER - OPERATING TEMPERATURES, BETWEEN -65 DEGREES C AND 150 DEGREES C - DUAL EXTRUDED WALL FOR OPEN APPLICATIONS - UV LASER PRINTABLE - PRODUCT STANDARD |
EN 4612-002:2011 | Aerospace series - Cables, electrical, for general purpose, single and multicore assembly - XLETFE Family - Jacketed or screened and jacketed - Part 002: General |
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.