• Shopping Cart
    There are no items in your cart

EN 50065-4-6:2004

Current

Current

The latest, up-to-date edition.

Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 4-6: Low voltage decoupling filters - Phase coupler

Published date

14-07-2004

Sorry this product is not available in your region.

1 Scope
2 Normative references
3 Definitions
4 Classification
  4.1 Type 1 (standard type)
  4.2 Type 2 (low leakage type)
5 Requirements
  5.1 Marking
  5.2 Electrical characteristics at mains frequency
      5.2.1 Over voltage
      5.2.2 Immunity
      5.2.3 Mains frequency leakage current
  5.3 Electrical characteristics at signalling frequency
      5.3.1 Operating frequency range
      5.3.2 Transfer function
      5.3.3 Impedance
Annex A (normative) Special national conditions

This European Standard applies to phase couplers in a mains communication system for phase to neutral voltage not exceeding 250 V a.c. and a nominal current not exceeding 125 A, intended for household and similar fixed installation including residential, commercial and light industrial buildings.This European Standard applies to phase couplers used to control the coupling of communication signals between phases or sections of a mains communication system.A “phase coupler” may be used to achieve coupling between the phases of a multiphase installation, or to provide bridging of signals around other system components.The standard definesthe requirements to ensure a minimum coupling between the sections, andthe requirements to ensure no change on the safety of the electrical installation.

Committee
CLC/TC 219
DocumentType
Standard
PublisherName
European Committee for Standards - Electrical
Status
Current

CEI CLC/TR 50412-1 : 2008 POWER LINE COMMUNICATION APPARATUS AND SYSTEMS USED IN LOW-VOLTAGE INSTALLATIONS IN THE FREQUENCY RANGE 1,6 MHZ TO 30 MHZ - PART 1: GENERAL
S.R. CLC/TR 50627:2015 STUDY REPORT ON ELECTROMAGNETIC INTERFERENCE BETWEEN ELECTRICAL EQUIPMENT/SYSTEMS IN THE FREQUENCY RANGE BELOW 150 KHZ
I.S. EN 50090-5-1:2005 HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 5-1: MEDIA AND MEDIA DEPENDENT LAYERS - POWER LINE FOR HBES CLASS 1
CEI CWA 50487 : 2006 SMARTHOUSE CODE OF PRACTICE
CEI EN 50090-5-1 : 2005 HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 5-1: MEDIA AND MEDIA DEPENDENT LAYERS - POWER LINE FOR HBES CLASS 1
OVE/ONORM EN 50090-5-1 : 2005 HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 5-1: MEDIA AND MEDIA DEPENDENT LAYERS - POWER LINE FOR HBES CLASS 1
BS EN 50090-5-1:2005 Home and building electronic systems (HBES) Media and media dependent layers. Power line for HBES Class 1
CLC/TR 50627:2015 Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz
ISO/IEC 14543-3-5:2007 Information technology Home electronic system (HES) architecture Part 3-5: Media and media dependent layers Power line for network based control of HES Class 1
PD CLC/TR 50627:2015 Study Report on Electromagnetic Interference between Electrical Equipment/Systems in the Frequency Range Below 150 kHz
EN 50090-5-1:2005 Home and Building Electronic Systems (HBES) - Part 5-1: Media and media dependent layers - Power line for HBES Class 1
CLC/TR 50412-1:2007 Power line communication apparatus and systems used in low-voltage installations in the frequency range 1,6 MHz to 30 MHz - Part 1: General
04/300967 DC : DRAFT JAN 2004 EN 50090-5-1 ED.1 - HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 5-1: MEDIA AND MEDIA DEPENDENT LAYERS - POWER LINE FOR HBES CLASS 1
S.R. CLC/TR 50412-1:2007 POWER LINE COMMUNICATION APPARATUS AND SYSTEMS USED IN LOW-VOLTAGE INSTALLATIONS IN THE FREQUENCY RANGE 1,6 MHZ TO 30 MHZ - PART 1: GENERAL
CSA ISO/IEC 14543-3-5 : 2008 INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-5: MEDIA AND MEDIA DEPENDENT LAYERS - POWERLINE FOR NETWORK BASED CONTROL OF HES CLASS 1
CSA ISO/IEC 14543-3-5 : 2008 : R2013 INFORMATION TECHNOLOGY - HOME ELECTRONIC SYSTEM (HES) ARCHITECTURE - PART 3-5: MEDIA AND MEDIA DEPENDENT LAYERS - POWERLINE FOR NETWORK BASED CONTROL OF HES CLASS 1

EN 50065-4-1:2001 Signalling on low-voltage electrical installations in the frequency range 3 kHz to 148,5 kHz - Part 4-1: Low voltage decoupling filters - Generic specification
EN 50065-2-2:2003/A1:2005/corrigendum Oct. 2006 SIGNALING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-2: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN INDUSTRIAL ENVIRONMENTS
EN 50065-2-1 : 2003 AMD 1 2005 SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 2-1: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 95 KHZ TO 148,5 KHZ AND INTENDED FOR USE IN RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRIAL ENVIRONMENTS
EN 50065-4-2 : 2001 AMD 2 2005 SIGNALLING ON LOW VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148,5 KHZ - PART 4-2: LOW VOLTAGE DECOUPLING FILTERS - SAFETY REQUIREMENTS
EN 50065-2-3 : 2003 AMD 1 2005 SIGNALLING ON LOW-VOLTAGE ELECTRICAL INSTALLATIONS IN THE FREQUENCY RANGE 3 KHZ TO 148.5 KHZ - PART 2-3: IMMUNITY REQUIREMENTS FOR MAINS COMMUNICATIONS EQUIPMENT AND SYSTEMS OPERATING IN THE RANGE OF FREQUENCIES 3 KHZ TO 95 KHZ AND INTENDED FOR USE BY ELECTRICITY SUPPLIERS AND DISTRIBUTORS

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.