• EN 50091-1-2 : 98 COR 1 99

    Superseded A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

    Available format(s): 

    Superseded date:  16-01-2003

    Language(s): 

    Published date:  12-01-2013

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    1 General
    1.1 Scope
    1.2 Normative references
    1.3 Definitions
    1.4 General requirements
    1.5 General conditions for tests
    1.6 Components
    1.7 Power interfaces
    1.8 Marking and instructions
    2 Fundamental design requirements
    2.1 Protection against electric shock and energy hazards
    2.2 Insulation
    2.3 Safety Extra-Low Voltage (SELV) Circuits
    2.4 Limited current circuits
    2.5 Provisions for protective earthing
    2.6 A.C. and d.c. power isolation
    2.7 Overcurrent and earth fault protection
    2.8 Protection of service personnel
    2.9 Clearances, creepage distances and distances through
        insulation
    2.10 External signalling circuits
    2.11 Limited power source
    2.12 Protection of the applied load
    2.13 Connection to other equipment
    3 Wiring, connections and supply
    3.1 General
    3.2 Connection to power sources
    3.3 Wiring terminals for external power conductors
    4 Physical requirements
    4.1 Stability and mechanical hazards
    4.2 Mechanical strenght and stress relief
    4.3 Construction details
    4.4 Resistance to fire
    4.5 Battery location
    5 Thermal and electrical requirements
    5.1 Heating
    5.2 Earth leakage current
    5.3 Electric strength
    5.4 Abnormal operating and fault conditions
    Annex A (normative) Test for resistance to heat and fire
    Annex B (normative) Motor test under abnormal conditions
    Annex C (normative) Transformers
    Annex D (normative) Measuring instruments for earth
            leakage current test
    Annex E (normative) Temperature rise of a winding
    Annex F (normative) Measurements of creepage
    Annex G (normative) Earth leakage current for UPS intended
            to be connected directly to IT power systems
    Annex H (informative) Guidance on protection against ingress
            of water and foreign objects
    Annex J (informative) Tables of electrochemical potentials
    Annex K (normative) Thermal controls
    Annex L (normative) Backfeed protection test
    Annex M (normative) Reference load conditions
    Annex N (normative) Ventilation of battery compartments
    Annex P (normative) Minimum and maximum cross-sections
            for copper conductor
    Annex Q (informative) A-Deviations
    Annex R (normative) Special national conditions

    Abstract - (Show below) - (Hide below)

    Applicable to electronic indirect a.c. convertor systems with an electrical energy storage device in the d.c. link. Main function of the UPS covered is to ensure continuity of an alternative power source. Uninterruptible power system may also serve to improve the quality of the power source by keeping it within specified characteristics. Applies to UPS for use on distribution systems up to 1 000 V a.c. which are movable, stationary, fixed and for building in; intended to be installed in restricted access locations and details requirements for safety of service personnel. To ensure the safety of installed UPS both as a single UPS unit or as a system of interconnected UPS units, subject to installing, operating and maintaining the UPS in the manner prescribed by the manufacturer.

    General Product Information - (Show below) - (Hide below)

    Committee TC 22X
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Superseded
    Superseded By

    Standards Referenced By This Book - (Show below) - (Hide below)

    16/30350625 DC : 0 BS EN 62485-5 ED 1.0 - SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 5: LITHIUM-ION BATTERIES FOR STATIONARY APPLICATIONS
    EN 50272-2:2001 Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries
    DD ENV 50091-3:1999 Specification for uninterruptible power systems (UPS) Performance requirements and test methods
    CEI EN 50171 : 2002 CENTRAL POWER SUPPLY SYSTEMS
    IEC 62485-2:2010 Safety requirements for secondary batteries and battery installations - Part 2: Stationary batteries
    CEI EN 50272-2 : 2002 SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 2: STATIONARY BATTERIES
    VDE 0558-508 : 2001 CENTRAL POWER SUPPLY SYSTEMS
    DIN V ENV 50091-3 : 2000 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: PERFORMANCE REQUIREMENTS
    BS EN 50272-2:2001 Safety requirements for secondary batteries and battery installations Stationary batteries
    DIN EN 50272-2 : 2001 SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 2: STATIONARY BATTERIES
    BS EN 50171:2001 Central power supply systems
    VDE 0510-2 : 2001 SAFETY REQUIREMENTS FOR SECONDARY BATTERIES AND BATTERY INSTALLATIONS - PART 2: STATIONARY BATTERIES
    ENV 50091-3 : 98 AMD 1 99 UNINTERRUPTIBLE POWER SYSTEMS - PERFORMANCE REQUIREMENTS AND TEST METHODS
    EN 50171 : 2001 COR 2001 CENTRAL POWER SUPPLY SYSTEMS

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60146-4:1986 Semiconductor convertors. Part 4: Method of specifying the performance and test requirements of uninterruptible power systems
    ENV 50091-3 : 98 AMD 1 99 UNINTERRUPTIBLE POWER SYSTEMS - PERFORMANCE REQUIREMENTS AND TEST METHODS
    ENV 61000-2-2 : 1993 ELECTROMAGNETIC COMPATIBILITY (EMC) - ENVIRONMENT - COMPATIBILITY LEVELS FOR LOW-FREQUENCY CONDUCTED DISTURBANCES AND SIGNALLING IN PUBLIC LOW-VOLTAGE POWER SUPPLY SYSTEMS
    HD 384.4.41 S2:1996/A1:2002 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK
    EN 50091-2:1995/corrigendum Jan. 1998
    EN 60950:2000/corrigendum:2002 SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT
    HD 625.1 : 200S1 INSULATION COORDINATION FOR EQUIPMENT WITHIN LOW-VOLTAGE SYSTEMS - PRINCIPLES, REQUIREMENTS AND TESTS
    IEC 60364-4-482:1982 Electrical installations of buildings. Part 4: Protection for safety. Chapter 48: Choice of protective measures as a function of external influences. Section 482: Protection against fire
    HD 384.4.42 : S1 AMD 2 ELECTRICAL INSTALLATIONS OF BUILDINGS - PROTECTION FOR SAFETY - PROTECTION AGAINST THERMAL EFFECTS
    EN 60439-1:1999/A1:2004 LOW VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - PART 1 - TYPE TESTED AND PARTIALLY TYPE TESTED ASSEMBLIES
    IEC 60364-7-707:1984 Electrical installations of buildings. Part 7: Requirements for special installations or locations. Section 707: Earthing requirements for the installation of data processing equipment
    EN 50091-1-1:1996/corrigendum Aug. 2004
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    ISO 7000:2014 Graphical symbols for use on equipment Registered symbols
    IEC 61140:2016 Protection against electric shock - Common aspects for installation and equipment
    HD 243 : S12 GRAPHICAL SYMBOLS FOR USE ON EQUIPMENT - INDEX, SURVEY AND COMPILATION OF THE SINGLE SHEETS
    EN 60309-2:1999/A2:2012 PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 2: DIMENSIONAL INTERCHANGEABILITY REQUIREMENTS FOR PIN AND CONTACT-TUBE ACCESSORIES (IEC 60309-2:1999/A2:2012)
    HD 384.4.46 : 200S2 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 46: ISOLATION AND SWITCHING
    EN 60309-1:1999/A1:2007/AC:2014 PLUGS, SOCKET-OUTLETS AND COUPLERS FOR INDUSTRIAL PURPOSES - PART 1: GENERAL REQUIREMENTS (IEC 60309-1:1999/A2:2012)
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective