• EN 50131-2-5:2008

    Withdrawn A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

    Alarm systems - Intrusion and hold-up systems - Part 2-5: Requirements for combined passive infrared and ultrasonic detectors

    Available format(s): 

    Withdrawn date:  01-05-2011

    Language(s): 

    Published date:  26-09-2008

    Publisher:  European Committee for Standards - Electrical

    Pure ENs are not available for sale, please purchase a suitable national adoption

    Sorry this product is not available in your region.

    Add To Cart

    Table of Contents - (Show below) - (Hide below)

    Introduction
    1 Scope
    2 Normative references
    3 Definitions and abbreviations
    4 Functional requirements
    5 Marking, identification and documentation
    6 Testing
    Annex A (normative) - Dimensions & requirements
            of the standardised test magnets
    Annex B (normative) - General testing matrix
    Annex C (informative) - Walk test diagrams
    Annex D (normative) - Procedure for calculation of
            average temperature difference
    Annex E (informative) - Basic detection target for the
            basic test of detection capability
    Annex F (informative) - Equipment for walk test velocity control
    Annex G (informative) - Immunity to visible and near infrared
            radiation - Notes on calibration of the light source
    Annex H (informative) - Example list of small tools
    Annex I (informative) - Test for resistance to re-orientation
            of adjustable mountings
    Bibliography

    Abstract - (Show below) - (Hide below)

    This European Standard is for combined passive infrared and ultrasonic detectors installed in buildings and provides for security grades 1 to 4 (see EN 50131-1), specific or non-specific wired or fire-free detectors, and uses environmental classes I to IV (see EN 50130-5). This standard does not include requirements for combined passive infra red and ultrasonic detectors intended for use outdoors. A detector shall fulfil all the requirements of the specified grade. Functions additional to the mandatory functions specified in this standard may be included in the detector, providing they do not influence the correct operation of the mandatory functions. The European Standard does not apply to system interconnections.

    General Product Information - (Show below) - (Hide below)

    Committee CLC/TC 79
    Development Note Supersedes CLC/TS 50131-2-5. (10/2008)
    Document Type Standard
    Publisher European Committee for Standards - Electrical
    Status Withdrawn
    Supersedes

    Standards Referenced By This Book - (Show below) - (Hide below)

    TR 103 056 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SYSTEM REFERENCE DOCUMENT; SHORT RANGE DEVICES (SRD); TECHNICAL CHARACTERISTICS FOR SRD EQUIPMENT FOR SOCIAL ALARM AND ALARM APPLICATIONS
    PD CLC/TR 50531:2009 Alarm systems. Terms and definitions
    S.R. CLC/TR 50531:2009 ALARM SYSTEMS - TERMS AND DEFINITIONS
    CLC/TR 50531:2009 Alarm systems - Terms and definitions

    Standards Referencing This Book - (Show below) - (Hide below)

    IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
    IEC 60404-8-1:2015 Magnetic materials - Part 8-1: Specifications for individual materials - Magnetically hard materials
    EN 60068-1:2014 Environmental testing - Part 1: General and guidance
    IEC 60404-14:2002 Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method
    IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
    IEC 60404-5:2015 RLV Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties
    EN 50131-1:2006/A2:2017 ALARM SYSTEMS - INTRUSION AND HOLD-UP SYSTEMS - PART 1: SYSTEM REQUIREMENTS
    EN 50131-6:2017 Alarm systems - Intrusion and hold-up systems - Part 6: Power supplies
    EN 60404-5:2015 Magnetic materials - Part 5: Permanent magnet (magnetically hard) materials - Methods of measurement of magnetic properties
    EN 50130-4:2011/A1:2014 ALARM SYSTEMS - PART 4: ELECTROMAGNETIC COMPATIBILITY - PRODUCT FAMILY STANDARD: IMMUNITY REQUIREMENTS FOR COMPONENTS OF FIRE, INTRUDER, HOLD UP, CCTV, ACCESS CONTROL AND SOCIAL ALARM SYSTEMS
    EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
    EN 60404-14:2002 Magnetic materials - Part 14: Methods of measurement of the magnetic dipole moment of a ferromagnetic material specimen by the withdrawal or rotation method
    IEC 60068-2-52:2017 Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution)
    EN 50130-5:2011 ALARM SYSTEMS - PART 5: ENVIRONMENTAL TEST METHODS
    • Access your standards online with a subscription

      Features

      • Simple online access to standards, technical information and regulations
      • Critical updates of standards and customisable alerts and notifications
      • Multi - user online standards collection: secure, flexibile and cost effective